Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards.
2 Model VFCD/VFCB V ertical Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection.
3 Model VFCD/VFCB V ertical Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Mounting Instructions ...................... 3 Unit Dimensions / Weights .................. 4 Inlet and Outlet Duct Details .
4 Model VFCD/VFCB V ertical Fan Coil ® Chilled Water Coil Conditions Fin Height: 22.5 Fin Width: Width-7 Fins Per Inch: 10 Fin Surface: B Circuiting: Half Ent.
5 Model VFCD/VFCB V ertical Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B C D 600 20.00 22.50 22.63 0.875 800 20.00 22.50 22.63 0.875 1300 24.
6 Model VFCD/VFCB V ertical Fan Coil ® NOTE With airflow from left to right, the fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). The other two coil connections should be capped off (Cap). Chilled W ater • 4, 6 or 8 Row C B A E D F 1.
7 Model VFCD/VFCB V ertical Fan Coil ® Filter Sizes and Quantity Model V ertical Filter Size (inches) Quantity Face Area (ft 2 ) VFCD/VFCD-600 20 x 24 1 2.7 VFCD/VDFCB-800 20 x 24 1 2.7 VFCD-VFCB-1300 20 x 24 1 2.7 VFCD/VFCB-1600 24 x 24 1 3.6 VFCD/VFCB-2000 16 x 25 2 4.
8 Model VFCD/VFCB V ertical Fan Coil ® 4. Air Volume Check and Measurement Along with the building balance, the unit’ s air volume (cfm) should be measured and compar ed with its rated air volume. This unit is flexible for varying air volume, but the actual air volume should be known for making final adjustments.
9 Model VFCD/VFCB V ertical Fan Coil ® Speed Contr ols Speed controls may be used on Model VFCD fans for manual adjustment of the fan’ s performance (for final system balancing) or to control the fan’ s output in confined spaces, such as conference or meeting rooms.
10 Model VFCD/VFCB V ertical Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Brok.
11 Model VFCD/VFCB V ertical Fan Coil ® Hot W ater , Chilled W ater and DX Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections.
12 Model VFCD/VFCB V ertical Fan Coil ® 2P = minimum 2P = minimum Drain Pan / Drain T rap Drain Pan / Drain T rap Drain lines and traps should be run full size from the drain pan connection. Drain pans should have drain lines and traps to permit the condensate from the coils to drain freely .
13 Model VFCD/VFCB V ertical Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r e-lubricatable and will need to be re- greased depending on fan use.
14 Model VFCD/VFCB V ertical Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance. Check once a year under normal operating conditions and, if dirty , brush or vacuum clean.
15 Model VFCD/VFCB V ertical Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ ____________________________________________.
Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the purchase date. Any units or parts which pr ove defective during the warranty period will be replaced at our option when returned to our factory , transportation pr epaid.
デバイスGreenheck Fan 464696の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Greenheck Fan 464696をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGreenheck Fan 464696の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Greenheck Fan 464696の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Greenheck Fan 464696で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Greenheck Fan 464696を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGreenheck Fan 464696の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Greenheck Fan 464696に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGreenheck Fan 464696デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。