LG ElectronicsメーカーPACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPの使用説明書/サービス説明書
ページ先へ移動 of 24
LG PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMP OWNER'S MANUAL LG http://www.lgservice.com Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your air conditioner. IMPORT ANT Please read through this manual.
2 Room Air Conditioner P ackaged T erminal Air Conditioner/Heat Pump Owner's Manual T ABLE OF CONTENTS FOR Y OUR RECORDS Write the model and serial numbers here: Model # Serial # Y ou can find them on a label on the side of each unit.
ENGLISH Owner’ s Manual 3 Safety Precautions Safety Precautions T o prev ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage.
4 Room Air Conditioner Safety Precautions ■ Operation Do not place the power cor d near a heater . • It ma y cause fire and electric shock. Do not allow water to run into electric parts. • It will cause f ailure of machine or electric shock. Use a soft cloth to c lean.
ENGLISH Owner’ s Manual 5 Safety Precautions CAUTION ■ Installation Do not operate or stop the unit by inserting or pulling out the power plug. • It will cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cor d.
6 Room Air Conditioner Safety Precautions ■ Operation Be cautious not to touch the sharp edges when installing. • A sev ere cut or other injur y could result.
Before Oper ation Owner’ s Manual 7 ENGLISH Bef ore Operation 1. Contact an installation specialist f or installation. This is NO T a do-it-yourself project. 2. Plug in the power plug properly . 3. Use a dedicated circuit. 4. Do not use an extension cord.
8 Room Air Conditioner Introduction This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that could cause harm to the air conditioner . This symbol indicates special notes. NOTICE This appliance should be installed in accordance with the National Electric Code.
Electrical Safety Owner’ s Manual 9 ENGLISH Electrical Safety Electrical Data 115V~ 230V~ 265V~ Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button.
10 Room Air Conditioner Electrical Safety IMPORT ANT (PLEASE READ CAREFULL Y) FOR THE USER'S PERSONAL SAFETY , THIS APPLIANCE MUST BE PROPERL Y GROUNDED The power cord of this appliance is equipped with a three-prong (grounding) plug. Use this with a standard three-slot (grounding) wall po wer outlet to minimize the hazard of electric shock.
Owner’ s Manual 11 ENGLISH Installation How to Install the Unit Installation 406 mm (16") 406 mm (16") 1,066 mm (42") 1066 mm (42") 318 mm (12 1 / 2 ") 318 mm (12 1 / 2 &quo.
12 Room Air Conditioner Installation • UNIT INST ALLA TION 1. Remov e the shipping screw from the v entilation door . 2. Remov e the front gille by pulling it out at the bottom to release it, then lift it up along the unit top front. 3. Slide the unit into the wall slee ve and secure with 6 screws through the unit flange holes .
Control Locations Owner’ s Manual 13 ENGLISH Contr ol Locations Manual Contr ols TEMPERA TURE CONTROL Set the Ther mostat control to the desired temperature mark 5 (the mid-point is a good star ting position). If the room temperature is not satisfactory after a reasonable time , adjust the control to a cooler or warmer setting, as appropriate.
14 Room Air Conditioner Control Locations Electr onic Controls The controls will look like one of the f ollowing. TEMP MODE HEA T E/SA VE FA N FA N COOL COOL HIGH HIGH LOW LOW TIMER TIMER F AN TIMER ' F ON OFF ON OFF POWER MODE - Push this button to cycle through the modes from COOL → FAN → HEAT → COOL.
Control Locations Owner’ s Manual 15 ENGLISH Self-Di a gnosis FUNCTION: If the unit has a malfunction, a green OPERA TIONLED located on the Display PCB used b y the unit to indicate the errors.
16 Room Air Conditioner Control Locations Additional Contr o ls • REMO VING THE FRONT GRILLE Additional controls are av ailable after removing the front grille and option cov er of control box. T o remove the front grille, pull out the bottom of front grille and then lift up.
Control Locations Owner’ s Manual 17 ENGLISH • REMO TE/LOCAL CONTROL When remote/local switch #1 is on, it allo w the unit to operate by the Remote W all Ther mostat. The unit control by knobs are not a vailab le. • ENERGY SA VER The energy sav er switch #2 is on.
18 Room Air Conditioner Control Locations 1. Remov e the front grille. 2. T o remove the front grille, pull out the bottom of the front grille and then lift up.
Maintenance and Service Owner’ s Manual 19 ENGLISH Maintenance and Service Air Filter Cleaning Ve n t F i l t e r TURN THE AIR CONDITIONER OFF AND REMO VE THE PLUG FR OM THE PO WER OUTLET . The air filter should be check ed at least twice a month to see if cleaning is necessar y .
20 Room Air Conditioner Maintenance and Ser vice Chassis Drainage(Optional) Cabinet Fr ont Corr osion Resistant Models Compressor / Fan Motor The chassis must be cleaned e very four months or more often as the atmospheric conditions require. Use water and detergent to clean the basepan, center partition and coils.
Maintenance and Service Owner’ s Manual 21 ENGLISH Common Pr oblems and Solutions T roub leshooting Normal Operation T roubleshooting Tips save time and mone y! Re view the char t below first and y ou may not need to call f or ser vice.
22 Room Air Conditioner Maintenance and Ser vice COMPLAINT CA USE REMED Y ■ Grommets ■ Fa n ■ Loose set screw ■ Worn bearings ■ V oltage ■ Wiring ■ Rotary ■ Thermostat ■ Capacitor (Discharge capacitor before servicing.) ■ Compressor ■ Overload • Check grommets; if worn or missing, replace them.
Maintenance and Service Owner’ s Manual 23 ENGLISH NAME PLA TE RA TING MINIMUM MAXIMUM 208/230 V 187 V 253 V ROOM AIR CONDITIONER V OL T A GE LIMITS COMPLAINT CA USE REMED Y ■ Vo l t a g e ■ Ove.
P/No. 3828A20308C Printed in Korea LG ELECTRONICS, INC. LG Packaged Terminal Air Conditioner Limited Warranty - USA Should your LG Packaged Terminal Air Conditioner prove to be defective in materials or workmanship under normal use during the warranty period listed below, LG Electronics will replace the defective part(s).
デバイスLG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
LG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。LG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。LG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
LG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、LG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLG Electronics PACKAGED TERMINAL AIR CONDITIONER/HEAT PUMPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。