Miller ElectricメーカーOM-1589の使用説明書/サービス説明書
ページ先へ移動 of 64
XR-M W ire Feeder XR-M Air- And W ater-Cool ed Guns Processes Description MIG (GMA W) Welding Pulsed MIG (GMAW - P) Wire Feeder And Feeder Gun OM-1589 163 473F June 1999 Visit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor call 1-800-4-A-Miller .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T ABLE OF CONTENTS SECTION 8 − SYSTEM SETUP 27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1. System Setup Display Parameters 27 . . . . . . . . . . . . . . . . . . . . . . . .
dec_con 1 1/96 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). Note Manufacturer ’ s Name: Miller Electric Mfg. Co. Manufacturer ’ s Address: 1635 W .
.
OM-1589 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-1589 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly of f from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-1589 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-1589 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-1589 Page 5 SECTION 1 − CONSIGNES DE SECURITE − LIRE A V ANT UTILISA TION som _nd_fre 5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives.
OM-1589 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage.
OM-1589 Page 7 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLOSION.
OM-1589 Page 8 1-4. Principales normes de sécurité Safety in W elding and Cutting, norme ANSI Z49.1, de l’American Wel- ding Society , 550 N.W. Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-1589 Page 9 SECTION 2 − DEFINITIONS 2-1. W arning Label Definitions A.. W arning! Watch Out! There are possible hazards as shown by the symbols. B.. Drive rolls can injure fingers C.. Welding wire and drive parts are at welding voltage during operation − keep hands and metal objects clear .
OM-1589 Page 10 2-2. Manufacturer ’ s Rating Label for CE Products 178 794-A For label location see Section 3-4. S/N: 24 3.0 Hz 50/60 IP 23 V 100 A 400 X 100 % MILLER ELECTRIC MFG. CO., APPLETON, WI USA V U 1 = A I 1 = 1 U 2 = I 2 = 2-3. Symbols And Definitions Some symbols are found only on CE products.
OM-1589 Page 1 1 SECTION 3 − INST ALLA TION 3-1. Specifications T y pe of Input Power W elding Power Source T y pe Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating IP Rating Overall.
OM-1589 Page 12 3-3. T ypical W ater-Cooled System Connections 801 810 / Ref. 175 086 / Ref. 180 31 1-B 1 300/400 Ampere Model CC/CV Inverter W elding Power Source .
OM-1589 Page 13 3-4. Rear Panel Connections Ref. 800 689 1 Rating Label Location 2 Coolant Supply Hose Route supply hose and connect to rear of Water T o Gun fitting in feeder . 3 Weld Cable If using conventional welding power source, route through reed relay in feeder .
OM-1589 Page 14 3-6. Internal Connections for W ater-Cooled Gun Ref. 800 688-B 1 Wire C o n duit 2 Thumbscrew 3 Wire Conduit Block Loosen thumbscrew and insert conduit into block.
OM-1589 Page 15 3-8. Front Panel Connections for Gun Ref. 800 688-B T ools N e e d e d : 5/8, 1 1/16, 1-1/8 in W ater-Cooled Guns: 1 Gun Control Cable Insert plug into Gun Control receptacle, and tighten threaded collar . 2 Gas Hose Connect to Gas fitting on feeder .
OM-1589 Page 16 3-9. Removing T op Cover of Gun 800 942 1 T op Cover Push back and lift off as shown. T o reinstall cover , set rear of cover in gun, and push cover back, down, and forward until it clicks into posi- tion. 1 3-10. Adjusting Contact Tip Position Ref.
OM-1589 Page 17 3-12. Installing Wire Spool 800 690-A / 800 945 1 Wire Spool 2 T op Cover 3 Pressure Roll Assembly 4 Gun Contact Tip If wire spool is being replaced, open pressure roll assembly in gun, and cut welding wire off at contact tip. Retract wire onto spool.
OM-1589 Page 18 3-13. Threading W elding Wire Through Feeder Ref. 800 945 / 800 690-A 1 Wire Spool Location 2 T ension Arm 3 Mounting Arm 4 Wire Inlet Guide 5 Feeder Drive Roll 6 Wire Conduit 7 T ension Thumbnut 8 Jog Button 9 Pressure Roll Assembly 10 Gun Drive Roll Fo r wire sizes .
OM-1589 Page 19 3-14. Threading Welding Wire Through Feeder (Continued) Ref. 800 944 T ools N e e d e d : Pull and hold wire; cut off end. Hold wire tightly to keep it from unraveling. 6 in (150 mm) Open tension arm. Thread wire thru inlet guide, along drive roll groove, and into wire con- duit.
OM-1589 Page 20 SECTION 4 − OPERA TION 4-1. Operational T erms See Menu Guide for detailed programming steps. NOTE The following is a list of terms and their definitions as they apply to this wire f.
OM-1589 Page 21 4-3. Front Panel Controls 800 687-A 1 Display 2 Parameter Select Button Press button to move > on display . 3 Display Control Knob Tur n knob to change parameter pointed to by > . T urning knob one click causes Trim (arc length) to increase/decrease by one or V olt to increase/decrease by 0.
OM-1589 Page 22 4-4. Side and Rear Panel Controls Ref. 800 690-A / Ref. 800 869 1 Mode Display 2 Data Card Slot 3 Parameter Display 4 Parameter Increase Button 5 Parameter Decrease Button 6 Parameter Select Button Press button to move > in display .
OM-1589 Page 23 SECTION 5 − SETTING SEQUENCE P ARAMETERS 5-1. Sequence Parameters in a Program . See Menu Guide for detailed programming steps. Trim is arc length. If set to zero, arc length is short. If set to 99, arc length is long. If time is set to zero in Weld se- quence, welding continues until gun trigger is released.
OM-1589 Page 24 SECTION 6 − SETTING DUAL SCHEDULE P ARAMETERS 6-1. Selecting Dual Schedule Pair Dual Schedule is used with two consecutive weld programs 1 & 2, 3 & 4, 5 & 6, or 7 & 8. Any program type (MIG, Adaptive Pulse, or Pulse) can be combined in dual schedule.
OM-1589 Page 25 6-2. Dual Schedule Switch Diagrams 1 Momen 2P (Momentary-Contact 2-Pole Switch or DSS-10) 2 Maint 2P (Maintained-Contact 2-Pole Switch) 3 Maint 1P (Maintained-Contact 1-Pole Switch, Or DSS-8) 4 T rigger Allows dual scheduling after estab- lishing a welding arc.
OM-1589 Page 26 7-2. Installing Data Card 156 266-B 1 Label Apply label to data card. W rite pro- gram information on label. 2 Data Card 3 Card Slot For Blank Data Card: Insert card into slot. T o format card, turn On power . Select Card from menu. Data card formats when unit enters Card mode.
OM-1589 Page 27 SECTION 8 − SYSTEM SETUP 8-1. System Setup Display Parameters See Menu Guide for detailed programming steps. NOTE Display Setting Notes >System * Select the process the welding power source is able to do. >Range * W elding power source minimum and maximum voltage values are always needed.
OM-1589 Page 28 SECTION 9 − ST ANDARD PULSE WELDING PROGRAMS Apk = Peak Amperage, Abk = Background Amperage, PPS = Pulses Per Second, PWms = Pulse Width (milliseconds).
OM-1589 Page 29 9-3. Program 3 − Aluminum Wire Size/T ype: 3/64” ER 4043 Gas: 100% Argon / 20-Max CFH Gun Model: 30 Ft W ater-Cooled IPM / MPM Apk Abk PPS PWms V olts COMMENTS 875 500 195 270 3.0 30.5 820 480 185 270 3.0 29.4 765 460 175 270 3.0 29.
OM-1589 Page 30 9-5. Program 5 − Aluminum Wire Size/T ype: .030” ER 5356 Gas: 100% Argon / 20-40 CFH Gun Model: 30 Ft W ater-Cooled IPM / MPM Apk Abk PPS PWms V olts COMMENTS 875 340 78 144 2.4 25.0 820 335 73 140 2.3 24.4 765 330 70 138 2.2 24.1 710 325 67 133 2.
OM-1589 Page 31 9-7. Program 7 − Aluminum Wire Size/T ype: 3/64” ER 5356 Gas: 100% Argon / 20-Max CFH Gun Model: 30 Ft W ater-Cooled IPM / MPM Apk Abk PPS PWms V olts COMMENTS 875 485 140 250 3.0 31.5 820 470 135 240 2.9 30.9 765 450 11 7 235 2.8 29.
OM-1589 Page 32 SECTION 10 − TEACH POINTS 10-1. T each Points Explained The teach mode allows the user to create custom pulse programs. The teach mode has 15 teach points. At each teach point, the user can ad- just five parameters to shape the pulse waveform of the weld output.
OM-1589 Page 33 10-2. Redefining T each Points Ref. S-0259 / Ref. 154 109 1 IPM IPM determines the weld metal de- position rate. . Redefining IPM is not normally required unless special wire or unusual joint design is needed. Use front panel parameter select button to move > to select IPM.
OM-1589 Page 34 Date Program Number Wire Size/T ype Gas Flowrate CFH(L/min) Equipment Used − Power Source Serial Number Wire Feeder Serial Number Gun Model Weld Cable − Negative Positive Wire Manufacturer Mfg.
OM-1589 Page 35 SECTION 1 1 − MAINTENANCE AND TROUBLESHOOTING 1 1-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Clean And T ighten W eld T erminals Repair Or Replace Cracked W eld Cable 14-Pin Cord Gas Hose And Fittings Gun Cable Replace Cracked Parts 6 Months Blow Out Or V acuum Inside.
OM-1589 Page 36 1 1-3. Changing Gun Contact Tip and Liner 150 437 T ools N e e d e d : Remove top cover and open pressure roll assembly . 1 Contact Tip W rench Insert wrench into nozzle over contact tip. 2 Compression Nut Loosen nut. Pull out contact tip.
OM-1589 Page 37 1 1-5. Removing Air-Cooled Contact Tip Adapter 150 430-A 1 Barrel Extension Remove as shown. 2 Contact Tip 3 Compression Nut T o remove, see Section 1 1 -3. 4 Contact Tip Adapter 5 Head Tube 6 Head T ube Setscrew Loosen setscrews and remove adapter .
OM-1589 Page 38 1 1-7. Error Displays Ref. 800 687-A 1 Release T rigger Error Display This appears if the trigger is closed when the unit power is turned on, or if the trigger is stuck or defective. 2 No V olt Sensed Error Display The arc voltage sense circuit is not receiving feedback.
OM-1589 Page 39 1 1-8. Using Self T est Y Have only Factory-Autho- rized persons perform tests or replace parts. 1 Switch A This checks the gun switch in- crease position. 2 Switch B This checks the gun switch de- crease position. 3 T rigger This checks the gun trigger .
OM-1589 Page 40 1 1-9. T roubleshooting Y Disconnect power before troubleshooting. T rouble Remedy Pressing gun trigger does not energize feeder . Welding wire is not energized. Secure plug from gun control cable into Gun Control receptacle on feeder (see Section 3-8).
OM-1589 Page 41 Notes.
OM-1589 Page 42 SECTION 12 − ELECTRICAL DIAGRAM Figure 12-1. Circuit Diagram.
OM-1589 Page 43 184 771-A.
OM-1589 Page 44 Figure 12-2. Circuit Diagram For Gun 163 699.
OM-1589 Page 45 Notes.
OM-1589 Page 46 SECTION 13 − P ARTS LIST 800 959-A 77 35 40 72 26 27 28 29 30 63 47 35 23 5 6 7 8 10 11 13 12 1 2 3 4 14 16 15 17 18 19 20 21 22 25 43 44 45 74 36 58 57 3 2 33 34* 49 48 50 46 51 61 .
OM-1589 Page 47 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly Quanti ty 1 178 936 LABEL, warning general precautionary 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 +169 085 WRAPPER 1 .
OM-1589 Page 48 Description Part No. Dia. Mkgs. Item No. Figure 13-1. Main Assembly (Continued) Quanti ty 52 PC80 182 299 CIRCUIT CARD, HF filter 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-1589 Page 49 1 14 188-F 23 4 5 6 7 9 10 11 20 13 14 15 16 17 18 19 13 12 12 21 22 23 24 8 1* 3 *Includes Items 15-18 . Hardware is common and not available unless listed. Figure 13-2. Motor & Wire Drive Description Part No. Dia. Mkgs. Item No. Figure 13-2.
OM-1589 Page 50 Item 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 800 960 See Fig 13-1 . Hardware is common and not available unless listed. PC20 Figure 13-3. Panel, Front w/Components Description Part No. Dia. Mkgs. Item No. Figure 13-3. Panel, Front w/Components (Fig 13-1 Item 73) Quanti ty 1 ♦ 164 964 FITTING, mtg switch flow 1 .
OM-1589 Page 51 1 2 3 4 5 6 7 8 800 1 13-B . Hardware is common and not available unless listed. PC60 PC40 Figure 13-4. Panel, Side w/Components Description Part No. Dia. Mkgs. Item No. Figure 13-4. Panel, Side w/Components (Fig 13-1 Item 16) Quanti ty 1 147 139 T APE, adh acrylic double sided .
OM-1589 Page 52 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 7 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 800 434-A 3 5 19 . Hardware is common and not available unless listed. Figure 13-5. Barrel Assembly Description Part No. Dia. Mkgs. Item No.
OM-1589 Page 53 Description Part No. Dia. Mkgs. Item No. Figure 13-5. Barrel Assembly (Fig 13-6 Item 48) (Continued) Quanti ty 17 137 042 BARREL ASSEMBL Y , water cooled (XRM-15W & 30W models) . . . . . . . . . . . . . . . . (consisting of) 1 . . .
OM-1589 Page 54 801 000-C *Includes Item 36 . Hardware is common and not available unless listed. 48(Fig. 13−5) 55 59 57 58 56 53 1 61 60 62 2 52 8 3 4 5 6 6 7 9 10 11 12 13 14 15 13 16 17 18 63 20 19 21 22 23 64 23 65 24 25 26 27 28 29 30 32 33 34 35 31* 36 37 38 39 40 41 42 43 44 45 46 41 47 49 50 51 54 Figure 13-6.
OM-1589 Page 55 Description Part No. Dia. Mkgs. Item No. Figure 13-6. XRM-A & W Guns Quanti ty 1 133 479 COVER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-1589 Page 56 Description Part No. Dia. Mkgs. Item No. Figure 13-6. XRM-A & W Guns (Continued) Quanti ty 48 Fig 13-5 BARREL ASSEMBL Y 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty Questions? Call 1-8 00-4-A-M ILLE R for your local Miller distrib u t o r. miller_warr 1/99 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA 1999 Miller Electric Mfg. Co. 9/98 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Com pany 1635 West Spenc er S treet Applet on, W I 54914 US A International He adquarte rs.
デバイスMiller Electric OM-1589の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miller Electric OM-1589をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiller Electric OM-1589の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miller Electric OM-1589の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miller Electric OM-1589で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miller Electric OM-1589を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiller Electric OM-1589の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miller Electric OM-1589に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiller Electric OM-1589デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。