Arc Welding Power Source XMT 350 CC/CV Auto-Line OM-2247 212 857N 2007 − 11 Processes Description Multiprocess W elding ™ ™ File: MUL TIPROCESS V isit our website at www.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .
T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-2247 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _2007 − 04 7 Protect yourself and others from injury — read and follow these precautions. 1-1. Symbol Usage DANGER! − Indicates a hazardous situation which, if not avoided, will result in death or serious injury .
OM-2247 Page 2 W elding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health. FUMES AND GASES can be hazardous. D Keep your head out of the fumes. Do not breathe the fumes. D If inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.
OM-2247 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-2247 Page 4 1-4. California Proposition 65 W arnings W elding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer . (California Health & Safety Code Section 25249.
OM-2247 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE A V ANT UTILISA TION fre_som_2007 − 04 7 Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes.
OM-2247 Page 6 Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces.
OM-2247 Page 7 LES ACCUMULA TIONS DE GAZ risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D V eiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué.
OM-2247 Page 8 LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage.
OM-2247 Page 9 2-5. P r i nc i pa l e s n or me s d e s éc u r i té Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www .
OM-2247 Page 10.
OM-2247 Page 1 1 SECTION 3 − INTRODUCTION 3-1. Specifications Input V oltage Amperage Range in Max. Open- Circuit RMS Amps Input at Rated Load Output, 60 Hz 3-Phase at NEMA Load V oltages and Class .
OM-2247 Page 12 6 Minutes W elding 4 Minutes Resting 3-3. Duty Cycle And Overheating Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating. If unit overheats, output stops, a Help message is displayed and cooling fan runs.
OM-2247 Page 13 SECTION 4 − INSTALLATION 4-1. Dimensions And Weight Hole Layout Dimensions 24 in (610 A E A 1 1-3/4 in (298 mm) (610 mm) G F B 1-1 1/16 i n (42 mm) 17 in (432 mm) C 15-3/4 in (400 mm) D C D 19-3/32 in (485 mm) C E 8-1 1/16 i n (221 mm) 12-1/2 in (318 mm) F 1-17/32 in (39 mm) 804 801-A B G 1/4-20 UNC -2B thread W eight 80 lb (36.
OM-2247 Page 14 4-3. Connecting 1-Phase Input Power 804 531-A ! Installation must meet all Na- tional and Local Codes − have only qualified persons make this installation. ! Disconnect and lockout/tag- out input power before con- necting input conductors from unit.
OM-2247 Page 15 4-4. Connecting 3-Phase Input Power 804 531-A ! Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. ! Disconnect and lockout/tagout in- put power before connecting input conductors from unit.
OM-2247 Page 16 4-5. Electrical Service Guide NOTICE − INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not exceed +10% of rated input voltage. NOTICE − Actual input voltage should not be 10% less than minimum and/or 10% more than maximum input voltages listed in table.
OM-2247 Page 17 4-6. W eld Output Receptacles And Selecting Cable Sizes ! ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor .
OM-2247 Page 18 4-7. Remote 14 Receptacle Information Socket* Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. AJ B K I 24 VOL TS AC B Contact closure to A completes 24 volts ac contactor control circuit. B K I C L NH 1 15 VOL TS AC I 1 15 volts ac.
OM-2247 Page 19 ‘ 4-9. Optional Gas V alve Operation And Shielding Gas Connection Ref. 803 705-A / Ref. 803 691-C Obtain gas cylinder and chain to running gear , wall, or other station- ary support so cylinder cannot fall and break of f valve. 1 Cylinder 2 Regulator/Flowmeter Install so face is vertical.
OM-2247 Page 20 SECTION 5 − OPERATION V/A ADJUST ARC CONTROL ARC CONTROL REMOTE ELECTRODE HOT 5-1. Front Panel Controls 1 Power Switch . The fan motor is thermostatically controlled and only runs when cooling is needed.
OM-2247 Page 21 5-2. Meter Functions . The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Meter Reading At Idle Meter Reading While W elding Scratch Start TIG VA Actual V olts (OCV) Preset Amps 71.
OM-2247 Page 22 5-4. Lift-Arc TIG Procedure With Process Switch in the Lift-Arc TI G position, start an arc as follows: 1 TIG Electrode 2 W orkpiece T ouch tungsten electrode to work- piece at weld start point, hold electrode to workpiece for 1-2 seconds , and slowly lift electrode.
OM-2247 Page 23 SECTION 6 − MAINTENANCE & TROUBLESHOOTING 6-1. Routine Maintenance ! Disconnect power before maintaining. . Maintain more often during severe conditions.
OM-2247 Page 24 6-3. V oltmeter/Ammeter Help Displays . All directions are in reference to the front of the unit. All circuitry referred to is lo- cated inside the unit. 1 Help 1 Display Indicates a malfunction in the primary power circuit. If this display is shown, contact a Fac- tory Authorized Service Agent.
OM-2247 Page 25 Notes.
OM-2247 Page 26 SECTION 7 − ELECTRICAL DIAGRAM Figure 7-1. Circuit Diagram.
OM-2247 Page 27 21 1 328-F.
OM-2247 Page 28 SECTION − 8 − P ARTS LIST Ref. 803 690-H 1 2 3 4 5 6 8 9 10 12 13 15 16 17 18 19 20 21 22 23 24 25 26 28 29 30 31 32 34 35 36 37 38 39 42 43 45 47 46 48 49 50 51 52 53 54 55 56 57 58 59 60 61 63 64 66 68 67 69 70 71 72 73 11 44 65 74 41 76 75 49 62 62 MOD 1 MOD 2 40 17 14 77 Figure 8-1.
OM-2247 Page 29 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly Quantity 1 216 034 Wrapper (Includes Insulators and Safety Labels) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 256 Insulator , Side Rh (Not Shown) 1 .
OM-2247 Page 30 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly (Continued) Quantity 32 Nameplate, Rear (Order by Model and Serial Number) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ♦ Nameplate, Rear Aux (Order by Model and Serial Number) 1 .
OM-2247 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 8-1. Parts Assembly (Continued) Quantity 62 ♦♦ 218 183 Rcpt Assy , T w Lk Insul Fem (T weco T ype) (Fac-op) (Includes) 2 . . . . . . . . . . . . . . . . . . . . . . . . 209 473 Receptacle, T wist Lock T weco Style (Female) Power 1 .
OM-2247 Page 32 221 900-B 11 Label (6) located on top of Windtunnel. 10 8 6 13 9 4 2 12 4 7 3 3 5 1 1 2 12 View of RH Windtunnel Figure 8-2. W rapper/Label Location - French Units 14 15 16 Description Part No. Item No. Figure 8-2. W rapper/Label Location - French Units Quantity 1 218 545 Label, W arning Exploding Parts Can Serious Inj (French) 2 .
Notes 229895 MA TERIAL THICKNESS GAUGE.
Notes W o r k l i k e a P r o! Pros wel d and cut safel y . Read the safety rules at the beginni ng of this manual ..
Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 2007 − 01 Y our distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours.
PRINTED IN USA © 2007 Miller Electric Mfg. Co. 2007 − 01 Miller Elect ric Mfg. Co. An Illinois T ool Wo rks Compa ny 1635 West S pencer S treet Applet on, WI 5 4914 US A International He adquarte r.
デバイスMiller Electric XMT 350 CC/CVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Miller Electric XMT 350 CC/CVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはMiller Electric XMT 350 CC/CVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Miller Electric XMT 350 CC/CVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Miller Electric XMT 350 CC/CVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Miller Electric XMT 350 CC/CVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はMiller Electric XMT 350 CC/CVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Miller Electric XMT 350 CC/CVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちMiller Electric XMT 350 CC/CVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。