SuperiorメーカーNEC004-TDの使用説明書/サービス説明書
ページ先へ移動 of 20
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. HOMEOWNER'S CARE AND OPERA TION INSTRUCTIONS 33" DIRECT-VENT GAS FIREPLACE HEATERS P/N 725,023M REV.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. These appliances are designed to operate on natural or propane gas only. On Millivolt models the Input of the appliance can be varied from 13,500 to 17,500 BTU/HR. On Electronic models the input is fixed at 17,500 BTU/HR.
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 1 Millivolt Appliances - To light millivolt appliances refer to the detailed lighting instructions found in both English and French on pages 12 and 13 of these instruc- tions respectively.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE. Variable Flame Height Adjustment ( Millivolt Appliances only) 1. All Millivolt appliances are equipped with a variable gas control valve.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Periodically (After the Burning Season) Maintenance Task Accomplishing Person Procedure Cleaning Firebox Interior Check Flame Patterns and Flame Heig.
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Refer to Figure 5 and remove the front glass enclosure panel as follows : 1. Remove the top louver or radiant panel. 2. Open the hinged drop-down control com- partment panel. Flame Appearance and Sooting Proper flame appearance is a matter of taste.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Log Placement Figure 8 3 . Insert the alignment hole of the left twig over the front log's left pin. Rotate the left twig until it just touches the edge of the ember bed bracket. 4 . Insert the alignment hole of the right twig over the front log's right pin.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Electronic Appliance Checkout To light the burner, turn ‘ON’ the optional remote wall switch and turn the gas control switch to the “ON” position. Ensure the ignitor lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 11 .
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARRANTY Your gas appliance is covered by a limited twenty year warranty. You will find a copy of the war- ranty accompanying this manual. Please read the warranty to be familiar with its coverage. Retain this manual.
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Remote Control System (Standard) H0249 RCL Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Door Frame Kits - 4 piece (shown) Brass Finish 99L62 DFK-4B Brushed Stainless Finish 99L63 DFK-4BS Door Frame Kits - 2 piece Brass Finish 17M28 DTK-4B Brushed Stainless Finish 17M29 DTK-BS Door Frame Kits Decorative door frame kits are available for use with these appliances.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly.
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces in- structions.
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE MILLIVOL T GAS CONTROL SYSTEM 1. Spark ignitor will not light pilot after repeated triggering of ignitor button. 2. Pilot will not stay lit after carefully following the lighting instructions.
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION See Below. Disconnect the two black wires from the wire nuts. Test switch(s) for continuity with a multimeter.
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS LIST Natural Propane No. DESCRIPTION Part No. Qty. Part No. Qty. Gas Fireplace Assembly – – – – 1. Hood LB-91941FZ 1 LB-91941FZ 1 2. Louver LB-92400F 7 LB-92400F 7 3. Louver, (Base) LB-92402F 1 LB-92402F 1 4.
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS 9 4 1 2 5 14 6 3 2 11 10 13 8 15 7 41 40 21 43 23 22 24 42 26 25 30 31 32 33 34 35 36 27 37 20 12 44 16.
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by LENNOX HEARTH PRODUCTS P/N 725,023M REV. J 11/2004 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
デバイスSuperior NEC004-TDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Superior NEC004-TDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSuperior NEC004-TDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Superior NEC004-TDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Superior NEC004-TDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Superior NEC004-TDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSuperior NEC004-TDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Superior NEC004-TDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSuperior NEC004-TDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。