owner's manual MODEL NOS: 1403612; 1403622 2203612; 2203622 3003612; 3003622 FOR USE WITH NATURAL GAS ONLY f- _/ APPROVED ® M()DEL NOS. 1403611; 1403621 2203611 ; 2203621 3003611 ; 3003621 FOR USE WITH LIQUEFIED PETROLEUM (L.
Contents Your Warranty ................................ 2 Introduction .................................. 3 Basic Description .............................. 3 Optional Accessories ........................... 3 Safety Rules ............................
Introduction Please read our instructions before you install and use your furnace. This will help you obtain the full value from this furnace. It could help you avoid needless service costs, if the answer to the problem is found within this instruction manual.
Safety Rules WARNING READ THESE RULES AND THE INSTRUCTIONS CAREFULLY. FAILURE TO FOLLOW THESE RULES AND INSTRUCTIONS COULD CAUSE A MALFUNCTION OFTHE FURNACE. THIS COULD RESULT tN DEATH, SERIOUS BODILY INJURY, AND/OR PROPERTY DAMAGE. umn. The maximum inlet gas supply pressure is 13" water column.
Unpack Your Furnace This direct-vent furnace is packaged complete including the vent cap, vent tube and air inlet tube ready for instal- lation on an exterior wall with a total thickness of from 5 inches minimum to a maximum of 9 inches. Open the carton and remove all parts.
Locating Wall Furnace Consider the following points before attempting to install the furnace: ALL MODELS 1. This is a direct vent wall furnace. It must be installed on an OUTSIDE WALL for proper venting of flue gases (Fig. 1). 2. Wall furnace can be surface mounted on an outside wall up to 24 inches thick when using an optional VENT EXTENSION KIT.
Locating Wall Furnace (cont.) MODELS 1403622, 1403621, 2203622, 2203621, 3003622 and 3003621 (All other models have a built-in thermostat) Choose a location for the thermostat about 5 feet above the floor on an inside wall.
Installation (cont.) GAS AND ELECTRICAL SUPPLY OPENINGS Holes must be drilled for the gas line (and electrical supply if you use an optional Blower Kit). Drill a 1-1/2 inch hole in wall for gas line where indicated on cardboard template or refer to Fig.
Installation (cont.) INSTALL VENT CAP Outside, place a single strip of mastic (provided) around the back flange of the vent cap ("G" Fig. 5, page 8). In- stall the vent cap by inserting it into the air inlet tube and over the vent tube. IMPORTANT The top of the vent cap is embossed "TOP".
Gas Supply & Piping Gas control valve, within the furnace, is shipped with a seal over gas inlet tapping. Do not remove this seal until ready to connect piping. WARNING DANGER OF PROPERTY DAMAGE, BODILY INJURY OR DEATH. MAKE SURE THE FURNACE IS EQUIPPED TO OPERATE ON THE TYPE OF GAS AVAILABLE.
Gas Supply & Piping (cont.) GAS PtPE SIZES NATURAL GAS PIPE CAPACITY - BTU PER HOUR (INCLUDES FITTINGS) PIPE SIZE LENGTH OF PIPE - FEET 1/2 inch 3/4 inch 1 inch 20 92,000 190,000 350,000 40 63,000 130,000 245,000 60 50,000 105,000 195,000 L.
Thermostat Installation (cont.) 6. Snag thermostat cable through wall so that 6 inches of cable protrudes. 7. Route cable to wall furnace leaving enough excess cable to make the connections at the gas valve. MOUNTING THE THERMOSTAT 1. To remove the thermostat cover, grasp cover and pull straight outward.
Furnace Technical Information MODEl. TYPE INPUT * NUIBMm GAS RATING IrTU/NR 1403612 NAT. 14,000 1403611 L.P.G. 14,000 1403622 NAT. 14,000 1403621 LP.G. 14,000 2203612 NAT. 22,000 2203611 LP.G. 22,000 2203622 NAT. 22,000 2203621 LP.G. 22,000 3003612 NAT.
Start-Up Procedure Start the furnace using the procedures in section Operating Your Furnace on pages 15 through 19. WARNING DANGER OF BODILY INJURY OR DEATH LIQUEFIED PETROLEUM (L.E) GAS IS HEAVIER THAN AIR AND IT WILL SETTLE IN ANY LOW AREA, INCLUDING OPEN DEPRESSIONS AND IT WILL REMAIN THERE UNLESS AREA IS VENTILATED.
Operating Your Furnace BUILT-IN THERMOSTAT MODELS 1403611, 1403612, 2203611, 2203612, 3003611 and 3003612 Refer to this sheet and sheet 16 (or) 17 for "Safety, Operating Instructions" and "Turn Gas Off To Appliance." These furnaces are equipped with a manually operated piezo spark ignition device to ignite the pilot gas.
FOR YOUR SAFETY, READ BEFORE LIGHTING WILLIAMS GAS CONTROL VALVE P322053 & P322054 I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
A. B. FOR YOUR SAFETY, READ BEFORE LIGHTING WILLIAMS GAS CONTROL VALVE P295300A & P295301A I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand.
FOR YOUR SAFETY, READ BEFORE LIGHTING WILLIAMS GAS CONTROL VALVE P121200 & P171600 I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. B. FOR YOUR SAFETY, READ BEFORE LIGHTING WILLIAMS GAS CONTROL VALVE P295200A & P295201A I WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by hand.
How To Care For Your Furnace MAINTENANCE It is recommended that a competent serviceman perform these checks at the beginning of each heating season: a. Burner and Control Compartments Keep clean at all times. Clean all foreign materials from top of burner.
Troubleshooting Gravity Direct Vent Wall Furnace SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION 1. Pilot will not stay lit after carefully following lighting instructions. 2. Pilot burning - no gas to main burner. 3. Burner comes "On" but goes "Off" after operating for no apparent reason.
Troubleshooting ... (cont.) SYMPTOM 4, Furnace operates but turns "Off" before room temperature is attained. 5. Furnace not producing sufficient heat. 6. Furnace operates but will not shut "Off" when room temperature is attained. 7.
Williams Direct Vent Gas-Fired Wail Furnace REPLACEMENT PARTS FOR OPTIONAL BLOWER ACCESSORY 2302 MODELS: 2205611; 2205612; 2205621; 2205622 5005611; 500561 2; 5005621; 5005622 REF. NO. 1 2 3 4 5 NOTE: USE ONLY MANUFACTURE'S AUTHORIZED PARTS 6 7 8 9 10 PART NO.
Williams Direct Vent Gas-Fired Wall Furnace REPLACEMENT PARTS FOR MODELS: 1403611; 1403612; 1403621; 1403622 REF. NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 PART NO.
Williams Direct Vent Gas-Fired Wall Furnace REPLACEMENT PARTS FOR MODELS: 1 403611 ; 140361 2 1403621 ; 1403622 FOR PARTS lISTING SEE PAGE 24. USE ONLY MANUFACTURER'S AUTHORIZED PARTS --25 1.
owner's manual SERVICE MODEL NOS. 1403612 NAT 1403622 NAT 2203612 NAT 2203622 NAT 3003612 NAT 3003622 NAT 1403611 LPG 1403621LPG 2203611LPG 2203621LPG 3003611LPG 3003621LPG NOTE: CANADIAN MODEL N.
デバイスWilliams 2203611の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Williams 2203611をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWilliams 2203611の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Williams 2203611の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Williams 2203611で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Williams 2203611を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWilliams 2203611の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Williams 2203611に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWilliams 2203611デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。