Humidifiers and Humidistat Installation, Start-Up, and Operating Instructions NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation.
Step 1—Inspect Package and Check Equipment Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
Step 7—Make Water Connection If garden hose is not used for water supply: 1. Mount saddle valve on water line according to instructions supplied with valve. 2. Run 1/4-in. diameter (water line grade) tubing from saddle valve to adapter on solenoid valve and tighten compression fittings.
Remember to provide clearance for maintenance and evaporator pad removal. To access pad remove top or bottom cover to expose assembly (turn knob counter-clockwise). Step 3—Prepare Plenum Opening (See Fig. 2.) 1. Use template for marking humidifier opening.
7. Saddle valve assembly with adapter 8. Four sheet metal screws 9. Foam tape 10. Noise suppressor (use for water pressure over 60 psi) 11. Worm clamp for field-supplied drain tube 12. Humidifier maintenance instruction sticker 13. Carrier logo label Step 2— Select Location (See Fig.
Step 6—Mount Solenoid Valve The water solenoid valve should be mounted on top of humidifier enclosure. 1. To mount solenoid on top, see Fig. 10. a. Firmly press valve into the top inlet hole on enclosure. Seat valve flush against inlet hole. 2. If alternate mounting of solenoid is required, see Fig.
Step 1—Inspect Package and Check Equipment Inspect the contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incomplete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
Step 5—Install Bypass Duct Attach field-supplied 6-in. diameter duct, elbow, or starting collar with field-supplied 1/4-in. zip screws. Install supplied 6-in. damper in 6-in. duct connector. IMPORTANT: On systems with central cooling, the damper should be closed during cooling season to prevent bypass air.
Step 3—Prepare Plenum Opening (See Fig. 2.) 1. Use template for marking humidifier opening. 2. Tape in place on plenum making sure template is level. IMPORTANT: For humidifier to operate properly it must be level and mounted on a vertical surface. 3.
compression fittings. Plastic compression nut supplied with float valve should not be torqued greater than 25 in.-lb. For copper tubing installations: copper tubing may be connected to float valve by using a field-supplied 1/4 to 1/4 in. straight- through compression union.
5. Mount case horizontally over wires directly to wall using 2 long screws provided. 6. Replace faceplate and knob. Step 2—Duct Mounting (Low Voltage) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.
Step 5—Operation When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier.
デバイスCarrier HUMCCLFP1025-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier HUMCCLFP1025-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier HUMCCLFP1025-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier HUMCCLFP1025-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier HUMCCLFP1025-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier HUMCCLFP1025-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier HUMCCLFP1025-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier HUMCCLFP1025-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier HUMCCLFP1025-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。