1 INTRODUCTION Before Y ou Star t 2 Safe Use 2 MOUNTI NG REC OMME ND A TIONS General Guidelines ......................................................................................................................................................... 3 Sloped Ceiling Installations .
2 CIRCUIT BREAKER T rip the break er for the circuit y ou will be working on FUSE BO X Remove the fuse f or the circuit y ou will be working on SAFE USE • Inspect the contents of your c arton f or possible shipping or hand ling damage and repor t any suc h damage directly to your authorized Casablanca dealer .
3 Ceiling Height Pole Length 8 ʹ 0 ” standard 8 ʹ 6 ” standard 9 ʹ 0 ” 6 ” 9 ʹ 6 ” 12 ” 10 ʹ 0 ” 12 ” 11 ʹ 0 ” 18 ” 12 ʹ 0 ” 24 ” 13 ʹ 0 ” 36 ” 14 ʹ 0 ” 48 ” Before mounting your Casablanc a fan, read the following helpful recommendations.
GETTING ST AR TED Installing a New Ceiling F ixture O utlet Box If you do not have an existing fi xture located where you wish to place your Casablanca fan, an approved ceiling fi xture outlet box must be installed and wired.
Step 3. Attach the canop y to the cr ossbar mounting bracket with three of the 8-32 x 2 1 / 1 / 1 2 " long canopy screws and loc k wash ers provid ed with your Casa blan ca fan. Tigh ten usi ng the provided screwdriver until snug against the ceiling.
6 Step 4c. Using the provided Allen wrench, loosen the set screw several turns to allow installation of the downrod. read the downrod into the motor coupling until it stops turning. is wil l take at least four and a half full turns. Step 4d. Tighten the set screw securely with the provided Allen wrench to ensure safe operation of your fan.
7 Blade Scre w and W asher Blade Holder Blade Holder Scre w (2 per blade) Step 5a. Remove the five shipping bloc ks attached to the rotating motor plate using the provided Phillips screwdriver .
8 Step 6b . Line up the two clearance holes in the cap with the two threaded holes on the raised r im of the switch housing. Pr ess the cap onto the switch housing to seat the guide pins into the alignment holes of the switch housing. Step 6c. Using the two 8-32 3 / 8 ʺ screws removed in Step 4h, install the c ap onto the switch housing.
9 Canop y W asher Canop y Scre w Canop y Hatch Step 9a. T uck the wires into the canopy with the wire nuts pointed upwards so that the WH ITE and BLA CK wires are on opposite sides of the canopy and all wires are clear of the canopy opening. Step 9b .
10 SAFET Y FIRST : T o reduce the risk of electr ical shoc k, this fan must be installed with an isolating wall control/switch. SAFET Y FIRST : T o reduce the risk of electr ical shoc k, this fan must be installed with an isolating wall control/switch.
1 1 Send Signal Send Signal LED F an Control T o start the fan. Press the selected speed butto n to run the fan at the desired speed. 1=L ow speed 2=Medium speed 3=High speed T o turn off the fan. Press the F AN OFF button. Airfl ow Direction T o revers e the airfl ow press the RE VER SE butto n.
12 Please refer to this guide before requesting ser vice or contacting your dealer for assistance. TROUBLESHOO TING TIPS PROBLEM POSSIBLE REMEDIES F an will not star t • Chec k the main circuit fuses, circuit breakers, and wall switch position.
13 F or questions or to loc ate the nearest Casablanca Authoriz ed S er vice Center , call 1-888-335-5247 toll-free, or visit us on the W eb at www .casablancafanco .com. is de vice complies with P art 15 of the FCC rules. Oper ation is subject to the following two conditions: 1.
14 A UTHORIZED SER VICE CENTERS ALABAMA MOBILE 36618 AZALEA CITY SERVICE CENTER 251-341-0663 TUSCALOOSA 35405 L TG. & APPL./LIGHTING PLUS 205-345-8900 HUNTSVILLE 35816 SOUTHERN HOME & HEARTH INC. 256-534-1715 ALASKA ANCHORAGE 99518 PRIMARY ELECTRIC INC.
15 MONTICELLO 52310 REM ELECTRIC INC. 319-465-3346 DES MOINES 5031 1 ADV ANCED LIGHTING 515-255-5009 OWTS IOW A (CONTINUED) CARROLL 51401 J & L ELECTRIC INC. 712-792-2444 ISO CORAL VILLE 52241 RALSTON CREEK 319-351-2189 OWTSH/ISOA DA VENPORT 52803 SHAW ELECTRIC INC.
16 OHIO (CONTINUED) MAUMEE 43537 K.O.V ELECTRONIC REP AIR 419-865-8893 DA YTON 45419 LARKIN ELECTRIC CO. 937-294-41 15 COLUMBUS 43231 THE LAMP LIGHTER 614-891-7940 CLEVELAND 44109 WESTSIDE L TG. CTR. 216-459-1970 N. OLMSTED 44070 CHANDELIER SHACK INC.
デバイスCasablanca Fan Company C3U72Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Casablanca Fan Company C3U72Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCasablanca Fan Company C3U72Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Casablanca Fan Company C3U72Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Casablanca Fan Company C3U72Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Casablanca Fan Company C3U72Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCasablanca Fan Company C3U72Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Casablanca Fan Company C3U72Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCasablanca Fan Company C3U72Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。