CDAメーカーEVM9の使用説明書/サービス説明書
ページ先へ移動 of 12
E V M9 Extr act or s Manual for Inst allation, Use and Maintenanc e Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.
Important The manufacturer cannot be held r esponsible for injuries or losses caused by inc orrect use or inst allation of this product. Please note that the manufactur er reserves the right t o invalidate the guar antee supplied with this pr oduct following incorr ect installation or misuse of the appliance or use in a commer cial envir onment.
2 Using your Extr act or For best perf ormance, you should switc h on the extract or 1 5 minutes befor e starting to cook and lea ve it to run f or appro ximately 1 5 minutes after the end of cooking.
3 Car e and Maintenanc e IMPOR T ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACT OR WITHOUT FIRST SWIT CHING OFF THE ELE CTRICITY SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasiv e cleaner (including Cif) will scratc h the surface and could er ase the contr ol panel markings.
4 Fig. 5 Changing the Light IMPOR T ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACT OR WITHOUT FIRST SWIT CHING OFF THE ELECTRICITY SUPPL Y . DO NO T CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HO T . ALL OW IT T O COOL BEFORE REM OVING IT .
5 DOUBLE POLE SWIT CHED FUSED SPUR OUTLET USE A 3 AMP FUSE Mains Electricity Connection THIS APPLIANCE MUST BE C ONNECTED T O THE MAINS SUPPL Y BY A C OMPE TENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWIT CHED FUSED SPUR OUTLET AND PR O TECTED B Y A 3A FUSE.
6 Installation Y our extractor can be used to filter and r ecycle the air within your kitc hen, or to extract the air outside. When extr acting air to the outside, the unit can be vented as shown in the diagr am below . Note that we recommend the use of ducting with a diameter of 1 50mm.
7 Fitting your extr actor to the w all Next, remov e the top cover by loosening the scr ews (b), closing the front panel and then lifting the c over off. The extractor is mount ed using four scr ews. Ensur e that the wall fixings and scr ews are suit able for the wall mat erial.
8 Fitting your extr actor to the w all Insert the 4 wall plugs in to the holes and fix 2 scr ews in the top holes so that they ar e protruding fr om the wall by appro x 5mm (fig 1 2).
9 Using the extr act or as an extr action device W ork out the r equir ed height of the optional chimney for your ceiling and mount the c himney fixing brack et as shown in the (fig 1 6), then secur e the chimney as shown in (fig 1 7a). Finally , locate the chimney to the body of the extractor as shown in (fig 1 8).
10.
Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshir e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu Passionate about style T o cont act our Customer Car e Department, or f or Service, please contact us on the det ails below .
デバイスCDA EVM9の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA EVM9をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA EVM9の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA EVM9の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA EVM9で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA EVM9を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA EVM9の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA EVM9に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA EVM9デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。