2 Important This appliance is designed and manufactur ed solely for the cooking of domestic (household) f ood and is not suitable for an y non domestic application and ther ef ore should not be used in a commercial envir onment. The applianc e guar antee will be void if the appliance is used within a non domestic envir onment i.
3 Important Saf eguar ds and R ecommendations – Do not carry out any cleaning or maintenance without first disconnecting the appliance from the electrical supply. – During and after use of the hob, certain parts will bec ome very hot. Do not touc h hot parts.
4 Featur es and T echnical Data Fig. 1 Cooking P oints 1 . Auxiliary burner (A) - 1 ,00 kW 2. Semi-rapid burner (SR) - 1 ,75 kW 3. Rapid burner (R) - 3,00 kW 4. T riple ring burner (TR) - 3,50 kW Contr ol Panel 1 0. Right auxiliary burner (1) control knob 1 1 .
5 How t o use the hob Gas burners Gas flow to the burners is adjust ed by turning the knobs (illustrated in fig.2) whic h contr ol the valves. T urning the knob so that the indicator line points to .
6 WRONG C ORRECT Choice o f Burner The s ymbols print ed on the panel by the side of the knob indicate which burner you ar e controlling. Choose a suitable burner depending on the cookwar e diameter and capacity. The pan diameter should be suitable for the burner power to make the most of the burner's high efficiency and not waste fuel.
7 Cleaning and Maintenanc e Gener al Tips – Befor e cleaning the hob switc h it off and wait f or it to cool down. – Clean with a cloth, hot water and soap or liquid deter gent. – Do not use products whic h ar e abrasive, c orrosive or c hlorine based.
8 Fig. 8 Burners and Grids – These parts can be remov ed and cleaned with appropriat e products. – After cleaning, the burners and their flame spr eaders must be well dried and corr ectly r eplaced. – It is v ery important to c heck that the burner flame spreader and the cap have been corr ectly positioned.
9 Corr ect Position o f T riple Ring Burner The triple ring burner must be correctly positioned (see fig. 9); the burner ribs must be fitted in their housing as shown by the arrow . The burner corr ectly positioned must not rot ate (fig. 1 0). Then position the cap “ A ” and the ring “ B ” (figs.
10 TIPS FOR INS T ALLA TION Location – The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a r oom or space containing a bath or a show er . – The appliance must not be installed in a bed-sit r oom of less than 20m 3 .
11 Installation T echnical Inf ormation for the Installer In or der to install the hob into the kitchen fixture, a hole with the dimensions shown in fig. 1 2 has to be made, bearing in mind the following: – within the unit, between the bottom of the hob and the upper surface of a shelf there must be a clearance of at least 30 mm.
12 Fast ening the Installation Br ackets (fig. 1 5) – Each hob is pr ovided with an inst allation kit including brack ets and screws for fastening the top to fixtur e panels from 2 t o 4 cm thick.
13 Gas supply r equir ements Important Not e This appliance is supplied for use on NA TURAL GAS or LPG (chec k the gas regulation label attached on the appliance). – Appliances supplied for use on NA TURAL GAS: they are adjusted for this gas only and cannot be used on any other gas (LPG) without modification.
14 Gas Connection The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a suitably qualified and register ed installer .
15 Gas connection Cat: II 2H3+ The fitting (fig. 1 7) is made up of: – 1 nut “ A ” – 1 elbow fitting “ C ” – gasket “ F ” Connection t o the Gas Supply – Be careful when flexible pipes ar e used that they do not come into contact with moving parts.
16 Con v er sion to Natur al Gas or LPG Replacing the Burner Inject ors – Remove the pan supports, the burner caps and flame speader s. – Using a wrenc h, substitute the nozzle injector s “ J ” (Figs. 1 9 - 20) with those most suitable for the kind of gas for whic h it is to be used.
17 Regulating the Burner Minimum Set ting When changing from one type of gas to another , the minimum tap output must also be correct, considering that in this position the flame must be about 4 mm long and must remain lit even when the knob is turned sharply from the maximum t o the minimum position.
18 Mains Electricity Connection Incorr ect installation ma y be danger ous and the manufacturer can no t be held responsible. W arning! This appliance must be earthed The manufacturer declines all responsibility f or any problem caused b y failur e to observ e this rule.
19 Appliance Servicing CDA pr ovide a quality and effective after -sales service to cover all y our servicing needs. Please attac h your r eceipt to this page f or safekeeping. Please help us to help you by ha ving the following inf ormation available when booking a servic e-call: 1 .
Customer Car e Department • The G r oup Ltd. • Harby Road • Langar • Nottinghamshi r e • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : service@cda.eu W : www .cda.eu T o contact our Customer Car e Department, or for Service, please contact us on the det ails below .
デバイスCDA HCG 931の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CDA HCG 931をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCDA HCG 931の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CDA HCG 931の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CDA HCG 931で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CDA HCG 931を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCDA HCG 931の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CDA HCG 931に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCDA HCG 931デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。