ページ先へ移動 of 21
BREW CENTER-IT, COFFEE BREWING EQUIPMENT Cecilware sells value... Worldwide 43 -05 20th Avenue, Long Island City, NY 11105 TEL: 718-932-1414 FAX: 718-932-7860 MODELS Single BC301-IT Twin BC2-IT BC302-.
2 SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC301-IT BC2-IT BC302-IT Volts 120/240 120/240 120/240 Watts 4100 6200 6200 Amps 18 27 27 Wall Outlet (Receptacle) Power Cord CE202 – 30A optional 6-20R 6-30R 6-30R All Brew Centers are single phase with 3 wires plus a ground with cord and plug, except Eport 220V, 1 PH, (UROPEAN).
3 FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular design and reduced component count for ease of service. 3. Optional Low Water Temperature Lockout to prevent dispen sing at water temperatures below an adjustable threshold.
4 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer.
5 CANCEL POWER CANCEL microprocess or driven HOT WATER CAUTION PROGRAMMING INSTRUCTIONS The following is a Functional Description of the Single Station Brewer : Modes of Operation - Overview Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset.
6 MODES OF OPERATION – DESCRIPTIONS Initialization Mode: The following screen signifies the presence of this mode: CECILWARE &&&&& REV #.# Description – This mode is active only during the first few seconds after “power-on”.
7 Brewing State BREWING DDD K MM:SS HH:MMP Description – This screen is displayed when a Brew Cycl e is in progress. The time remaining in the Brew Cycle is displayed in the lower left-hand corner of the screen (depicted as “MM:SS”). The Brew Key LED will blink in this state.
8 SERVICE MODE Description – The main function of Service Mode is to gi ve qualified personnel the ability to configure the system to meet the requirements of each installation.
9 INFUSION TIME INFUSION TIME ## SECONDS Description – The Infusion Time is the amount of time that the system will dispense (infuse) hot water into the grinds during the Pre-Infusion process.
10 TEMPERATURE SENSOR CALIBRATION TEMP SENSOR CAL ARE YOU SURE ? Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water temperature to a reference thermometer. Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed temperature to match the reference thermometer.
11 WEEKDAY TIME OFF WEEKDAY TIME OFF ##:## #M Description – The Weekday Time OFF function allows the user to set the required weekday turn OFF time. WEEKEND TIMER WEEKEND TIMER ON/OFF Description .
12 ERROR MODE Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” usi ng the Power Key located on the membra.
13 PARTS IDENTIFICATION BC301-I T BC2-IT BC302-IT I TE M P/N QT Y P/N QT Y DESCRIPTION 1 SF26A 1 SB49A 1 CABINET TOP COVER 2 ---- NG35A NG37A -- 1 1 --- NG40A NG36A NG39A -- 1 1 1 TOUCH PAD LABEL: BC1.
14 TOP CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY P/N BC2-IT BC302-IT QTY DESCRIPTION 1 L656A 1 L656A 2 HI-LIMIT 2 L671A 1 L671A 1 THERMISTER PROBE 3 K355Q 1 K355Q 1 WATE R LEVEL CONTROL PROBE.
15 BOTTOM CABIN OPEN VIEW BOTTOM CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY P/N BC2-IT BC302-IT QTY DESCRIPTION 1 L069A 1 L069A 1 POWER SWITCH 2 CD257 1 CD257 1 WATER INLET VALVE 3 B083A 1 B08.
16 CLEANING AND SANITIZING SANITIZING: All food dispensing units should be sanitized periodically . All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F).
17 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1.
18 SPECIAL COMPONENTS TEST AND ADJUSTMENTS 1) WATER INLET VALVE (SOLENOID) TEST ( Located inside bottom cabin ) Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the ter minals.
19 5) CHECK DISPENSE VALVES FOR LIME BUILD-UP ( Located inside top cabin ) Drain The Water Tank To Just Below The Level Of The Dispense Valves. Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed.
20 120VAC T1 CH82A 2+ 1- THERMISTOR L617A SEE DETAIL-1 275V 0.1uf C1 HEATER TANK 3KW MT1 G SP1 SWITCH S1 POWER MT2 PROBE LEVEL OVER-FLOW HOSE SAFETY RELAY L55 3A K2 4 K1 3 WARM ER 100W #4 #3 #2 DILUTI.
21 THERMISTOR #L617A OVER TEMPE RATURE SENSOR ASSEMBLY SEE DATAIL-1 #M683A TEE #10054 TRIAC L623A 40A THERMISTOR L671A J2 J6 BATTERY- PANASONIC #CR2030 OR EQUIVALENT LCD CONT ROL BOARD L669A J1 TO KEY.
デバイスCecilware BC2-ITの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cecilware BC2-ITをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCecilware BC2-ITの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cecilware BC2-ITの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cecilware BC2-ITで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cecilware BC2-ITを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCecilware BC2-ITの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cecilware BC2-ITに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCecilware BC2-ITデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。