CecilwareメーカーBC302の使用説明書/サービス説明書
ページ先へ移動 of 18
BREW CENTER, COFFEE BREWING EQUIPMENT TWIN: BC2, BC302 SINGLE: BC1, BC301, BC120, BC240 MANUAL * Specifications * Start up procedure * Adjustments * Parts Identification * Installation * Operating Instructions * Care Maintenance * Wiring Diagram Cecilware sells value.
2 SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC1 BC301 BC120 BC240 BC2 BC302 Volts 120/240 120/240 120 240 120/240 120/240 Watts 4100 4100 1800 3120 6200 6280 Amps 18 18 15 13 27 27 Wall Outle.
3 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brew er. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the st raps and lifting the carton off the Brewer.
4 INITIAL PRIMING – Filling of Tank The BC Brewers are shipped with the Thermostat in the OFF position. Do not turn Thermostat to the ON position until the Brewer has been fully primed. a. Turn water supply on and check for leaks at the water inlet connections.
5 ADJUSTMENTS 1. BY-PASS FLOW VALVE ADJUSTMENTS Depending on the model number, the BC Brewers have been factory set to brew 12, 24 and/or 36 cups of coffee, with the BY-PASS adjusted for a 20% BY-PASS flow of brewing water for the 36 cup, brew output only.
6 R E MO VE JU MP E R F O R 240V 2. TIMER ADJUSTMENT PROCEDURE Remove the top cover to access the brew timer(s). To INCREASE output: turn timer knob a small increment CLOCKWISE. To DECREASE output: turn timer knob a small increment COUNTER-CLOCKWISE. Check output level in carrier.
SPECIAL COMPONENTS TEST 1) CHECK DISPENSE VALVES FOR LIME BUILD-UP ( Located inside top cabin ) Drain the water tank to just below the level of the Dispense Valves. Remove the Valves and clean. Y ou can take these valves apart by hand as shown. Replace the assembly as needed.
8 TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1.
9 CLEANING AND SANITIZING SANITIZING: All food dispensing units should be sanitized periodically . All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F).
10 PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] SINGLE UNITS BC1, BC301, BC120, BC240 TWIN UNITS BC2, BC302 I TE M P/N QTY P/N QT Y DESCRIPTION 1 SF26A 1 SB49A 1 CABINET TOP COVER 2 --- N829A N89.
11 TOP CABIN OPEN VIEW TOP CABIN - PARTS IDENTIFICATION [ * RECOMMENDED SPARE PARTS] ITEM SPARE PARTS SINGLE UNITS P/N QTY TWIN UNITS P/N QTY DESCRIPTION 1 * L656A 1 L656A 1 HI-LIMIT 2 * L499A M532A 1 1 L499A M523A 1 1 FLOAT SENSOR WITH RUBBER GASKET 3 * G367A G369A G286A 1 G367A G369A G286A 2 HEATER (1.
12 BOTTOM CABIN OPEN VIEW BOTTOM CABIN - PARTS ID ENTIFICATION [ * RECOMMENDED SPARE PARTS] SPARE PARTS BC301-IT BC2-IT BC302-IT ITEM P/N QTY P/N QT Y DESCRIPTION 1 * L069A 1 L069A 1 POWER SWITCH 2 B0.
13 CARRIER ASS’Y 97208 [ * RECOMMENDED SPARE PARTS] Item Description Part # 1 * Handle, black 3” 02015 2 2 * * Hold Down Bracket Thumb Screw U833A M299A 3 * * Carrier Cover S.
14 WHITE RED BLACK BREW CIRCUIT BREW VALVE R W B L L2 N FUSE 6 AMP. RED BLK GND L1 L1 LOAD REFILL CIRCUIT PROBE N HI LIMIT BLK D C.G. BC-1E 120/240 3 WIRES + GROUND 3100 WATTS 14A 1 PH 60Hz C.
15 BC120E 2 WIRES+GRD 1800W 15A 1PH A C.G. BC240E 2 WIRES+GRD 3120W 13A 1PH C.G. - A BLACK WHITE BC-240E DUAL BREWTIME BC-120E DUAL BREWTIME RED WARMER L2 S L1 SW2 SW3 I2 I1 12 CUP 24 CUP BREW INDICA TOR LIGHT HI LIMIT FUSE 6 AMP.
16 N L1 REFILL CIRCU IT HI LIMIT BLK RED WHITE BLACK 89 11 FUSE 6 AMP. RED BLK BLK N L2 GND L1 INLET VALVE PROBE LOAD C C.G. BC-301E 120/240 3 WIRES+GN D 4140W 18A 1PH 60HZ BC-301E TRIPLE BREW TIME BREW CIRCUIT 10 12 24 3 6 C.
17 C C.G. BC-2E 120/240 3 WIRE+GRD 6230W 26A 1PH 60HZ C.G. - C PROBE PROBE L1 LOAD N HI LIMIT BLK BLACK WHITE RED L BC-2E SINGLE BREW TIME W RB GND RED BLK L2 N L1 L B W R.
18 WHITE RED BLACK 12 CUP 24 CUP 36 CUP 11 24 CUP 12 CUP 36 CUP 9 8 10 RED BLK N L2 L1 GND D C.G. C.G. - D 24 CUP 12 CUP 36 CUP 24 CUP 36 CUP 12 CUP 11 9 81 0 PROBE LOAD L1 N HI LIMIT BLK.
デバイスCecilware BC302の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cecilware BC302をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCecilware BC302の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cecilware BC302の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cecilware BC302で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cecilware BC302を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCecilware BC302の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cecilware BC302に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCecilware BC302デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。