Operation Manual NL48A July 2005 GB4M-5.5-LD-U GB5-LD-U GB6M-10-LD-U GB8M-10-LD-U.
CONTENTS Important Owner Information _____________________________________1 Introduction ____________________________________________________1 Important Safety Instructions ___________________________.
IMPORTANT OWNER INFORMATION Record the model number, serial number (identification plate is located behind front door), voltage and purchase date of your Cecilware Cappuccino Dispenser in the spaces below. Please have the information available when calling Cecilware for assistance.
IMPORTANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property. IMPORTANT SAFETY INSTRUCTIONS WARNINGS The GB8M - 10 - LD - U ( only ) is e quipped with two (2) power switches and two (2) 120 volt grounded power cords.
PLUG CONFIGURATION NEMA 5-15P NEMA 5-15R NEMA 5-15P NEMA 5-15R (2) DEDICATED OUTLETS 120 V 15 A Figure # 1 FOR GB8 MODELS ONLY MODEL DESCRIPTION GB8M - 10 - LD - U (shown) GB6M - 10 - LD - U (typical) These High V olume Cappuccino Dispensers will hold double the amount of your most popular flavor along with up to seven other flavors as well.
UNPACKING INSTRUCTIONS Carefully unpack the Cappuccino Dispenser Unit and inspect immediately for shipping damage. Your Cappuccino Dispenser Unit was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory.
START - UP PROCEDURE C aution: Make sure that the Heater Switches, are in the OFF position. 1. Connect the ¼ inch copper waterlines to the ¼ inch flare water inlet fittings of the valves. 2. Plug the power cords into dedicated receptacles. 3. Activate the Power Switch (Toggl e Up).
TROUBLESHOOTING GU IDE WARNING : To reduce the risk of electrical shock, DISCONNECT POWER CORDS before repairing or replacing any internal components of the unit. Before any attempt to replace a component be sure to check all electrical connections for proper connection .
Model L690A (Rev. B) Dual Probe Liquid Level Controller Overview - The L690A is a Dual Probe Liquid Level Controller designed to maintain a specific level of water in the tank. This device utilizes two level probes for increased reliability. Independent maximum fill timers are incorpor ated in the controller for overflow protection.
PRODUCT GUIDE PRODUCT GUIDE HOPPER (3) (CD185) WHIPPER CHAMBER HEATER LIGHT POWER SWITCH GRILL DRIP TRAY PAN 14.1" RINSE SWITCH 20.0" GRILL DRIP TRAY PAN POWER SWITCH RINSE SWITCH WHIPPER CHAMBER HEATER LIGHT UPPER DOOR OPEN GB4M- 5.5-LD-U 4 Flavor Cappuccino Dispenser Upper Door open, Lower Door not shown.
10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD185) 10 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs 5 Lbs HOPPER (CD180) 27.0" 21.5" DRIP TRAY PAN GRILL DRIP TRAY PAN (2) GRILL SLANTED WHIPPER CH.
11 5 7 1 12 8 6 4 3 10 2 9 WHIPPER CHAMBER 13 IMPORTANT: SLANTED WHIPPER CHAMBERS (SEE BELOW) ARE NOT INTERCHANGEABLE WITH STANDARD STRAIGHT WHIPPER CHAMBERS.
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 HOPPER COVER AUGER MOTOR #CD175 (90 RPM).
AGITATOR WHEEL W/SPRINGS AUGER BUSHING FRONT CD306 PRODUCT GUIDE, SHORT CD70A AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER.
PRODUCT GUIDE, SHORT AUGER BUSHING FRONT CD306 CD70A AGITATOR WHEEL W/SPRINGS AUGER BUSHING-BACK CD279 BEVELLED SOCKET CD271 NUT CD278 [2] HOPPER BASE CD140 AUGER MOTOR #CD175 (90 RPM) HOPPER COVER.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM QTY P/N 17.
DESCRIPTION ITEM QTY P/N.
DESCRIPTION ITEM GB8 22 GB6 GB5 UPPER DOOR GB4M-5.5-LD-U, GB5-LD-U GB6M-10-LD-U, & GB8M-10-LD-U GB4.
DESCRIPTION ITEM GB6 23 GB8 GB5 GB4 LOWER DOOR GB4M-5.5-LD-U, GB5-LD-U GB6M-10-LD-U, & GB8M-10-LD-U.
DESCRIPTION ITEM QTY P/N 21.
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 12" WIDE, 4.8" DEEP, 16.5" HIGH. APPROX. 3.7 GAL..
DESCRIPTION ITEM QTY P/N TANK DIMENSIONS: 15" WIDE, 6" DEEP, 18" HIGH. APPROX. 6 GAL..
.
WATER INLET VALVE AUGER DOOR UNIT WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH BREW SWITCH MAIN UNIT DISPENSE VALVE HI-LIMIT THERMOSTAT HEATER SWITCH RINSE SWITCH A2 44 NO 32 NC 22 NC 14 NO A1 43 NO 31 NC 21 NC 13 NO GND 5-15P 15A-1.
GB6M-10-LD-U.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - LEFT SIDE - 120V NE195 SHEET 1 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHTS REV A.
GB8M-10-LD-U & GB8M10WLD ELECTRICAL DIAGRAM - RIGHT SIDE - 120V NE195 SHEET 2 OF 2 WATER LEVEL PROBES LIQUID LEVEL CONTROL WATER DISPLAY LIGHT REV A.
デバイスCecilware GB4M-5.5-LD-Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cecilware GB4M-5.5-LD-Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCecilware GB4M-5.5-LD-Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cecilware GB4M-5.5-LD-Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cecilware GB4M-5.5-LD-Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cecilware GB4M-5.5-LD-Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCecilware GB4M-5.5-LD-Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cecilware GB4M-5.5-LD-Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCecilware GB4M-5.5-LD-Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。