DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building.
2 Gas Fireplace Insert 10002964 T able of Contents PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORT ANT - Read all instructions and warnings carefully before starting installation.
3 Gas Fireplace Insert 10002964 This gas appliance should be installed by a qualified installer , preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 Gas Fireplace Insert 10002964 A B C D J E F G H U V S T R Q 4“ P O N M L K 2964 A125_132 specs 10/06 Maintain 1” Clear- ance to ‘B’ V ent Zero Clearance Kit Gas Inlet Knock-out Air Inlet Cha.
5 Gas Fireplace Insert 10002964 Locating Y our Gas Fireplace Insert with Zero Clearance Kit C D B E A F X X X FP1249a locating DV unit with zero clearance kit 4/03 FP1249 a Fig. 1 Locating unit with zero clearance kit. A) Flat on wall B) Cross corner C) Island D) *Room divider E) *Flat on wall corner F) Chase installation NOTE: (Fig.
6 Gas Fireplace Insert 10002964 Combustion Air It is very important that an adequate air supply is available when the unit is being operated. Since most homes of today are tightly sealed and insulated, addi- tional make-up air is usually necessary .
7 Gas Fireplace Insert 10002964 CFM106 T ypical Gas Line Connection 9-29-00 1/2” Gas Supply 1/2” x 3/8” Reducer 3/8” Nipple 3/8” x 3/8” Shut Off V alve 3/8” Nipple 3/8” Union 3/8” Nipple CFM106 Fig. 4 T ypical gas line installation. When using copper or flex connector , use only approved fittings.
8 Gas Fireplace Insert 10002964 Leveling Bar Set Screws FP1658 Fig. 8 Adjust leveling bar on A132 only . 2' Min. 2' (610mm) Min. 3' Min. 0 To 10' 3' (914mm) Min.
9 Gas Fireplace Insert 10002964 Common Flue Installations In some areas it is possible to vent more than one gas fireplace into the same flue. Y ou must ensure the flue being shared has the proper capacity to handle both fireplaces. Check installation codes for venting capacity information.
10 Gas Fireplace Insert 10002964 Fan Kit Installation 1 15 V olt, 60 Hz. 56W The fan kit includes the following: fan, temperature sensor , speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation. 1. Plug in the electrical cord.
1 1 Gas Fireplace Insert 10002964 Operating Instructions General Glass Information Only ceramic glass approved by CFM Cor- poration may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of the glass.
12 Gas Fireplace Insert 10002964 Left Rear Log N15 Front Left Log N13 Right Rear Log N16 Front Right Log N14 Ember Material LG479 Figure 17.
13 Gas Fireplace Insert 10002964 First Firing Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge them- selves of this air .
14 Gas Fireplace Insert 10002964 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to " OFF ". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
15 Gas Fireplace Insert 10002964 W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot.
16 Gas Fireplace Insert 10002964 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo — 1/8" Gap To Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor For Air In The Lines Thermopile Needs A Minimum 325mv.
17 Gas Fireplace Insert 10002964 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
18 Gas Fireplace Insert 10002964 1 A125 1a 1b 1c 1d 3 2 4 5 9a/b 8a/b 19 14 16 18 10a/b 18 17 1 1a/b 13 14 15 20 23a/b 21 22a.
19 Gas Fireplace Insert 10002964 Ref. Description A125 A132 A125, A132 Gas Insert 9a. Orifice Pilot PSE - Nat. 10001822 10001822 9b. Orifice Pilot PSE - Prop. 10001823 10001823 10a. Pilot Assembly SIT T op Convertible - Nat. 10002389 10002389 10b. Pilot Assembly SIT T op Convertible - Prop.
20 Gas Fireplace Insert 10002964 Ceramic Refractory Optional for A125 and A132 Model Description RHE25CR Ceramic Firebox Liner 1. Remove front glass (Refer to Glass Frame Removal section) 2. Remove logs from unit. Logs may be hot! 3. Remove refractory from packaging.
21 Gas Fireplace Insert 10002964 5. Remove the two screws that hold the top brass trim. 6. Install the two brackets to the studs in the bottom of the top channel. Use the nuts supplied with top trim channel. A flat louvre kit OR a bay window kit need to be chosen to complete the installation.
22 Gas Fireplace Insert 10002964 1 2 3 4 5 FP1293 HE25FP parts 2/03 FP1293 HE25FP Replacement Parts CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
23 Gas Fireplace Insert 10002964 KT210 Install bay front 3/19/01 djt KT210a Fig. 34 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets. KT21 1a Install bay front upper grille 2/4/03 djt KT21 1a Fig. 35 Engage the slots in the upper grille top louvre with the upper tabs of the hanging brackets.
24 Gas Fireplace Insert 10002964 A4 Riser Kits For use with A125 1. Install the unit according to Homeowner ’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim.
25 Gas Fireplace Insert 10002964 4. Install the trim top deflector and fasten it (will hold the inner top piece). Use two (2) screws to assemble them. 5. Install trim channels (left and right sides). Use two (2) screws to assemble each piece. 6. Slide on the trim top channel and fasten it from the back side.
26 Gas Fireplace Insert 10002964 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. IMPORT ANT : Only trim panel assemblies ap- proved by CFM Corporation can be used on these products.
27 Gas Fireplace Insert 10002964 A4 Riser Kits For use with A125 1. Install the unit according to Homeowner ’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim.
28 Gas Fireplace Insert 10002964.
29 Gas Fireplace Insert 10002964.
30 Gas Fireplace Insert 10002964.
31 Gas Fireplace Insert 10002964 BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスCFM A125の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CFM A125をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCFM A125の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CFM A125の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CFM A125で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CFM A125を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCFM A125の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CFM A125に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCFM A125デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。