Chamberlainメーカー2280-267の使用説明書/サービス説明書
ページ先へ移動 of 36
The Chamberlain Group, Inc. 845 Larch A ven ue Elmhurst, Illinois 60126-1196 www .liftmaster .com GARAGE DOOR OPENER Model 2280 1/2 HP 2280-267 1/2 HP 2280-976 1/2 HP For Residential Use Only ® Owner.
2 Introduction Pages 2-5 Saf ety symbol and signal word re view ........................2 Preparing your garage door ........................................3 T ools needed ...............................................................3 Planning ....
3 To prevent damage to garage door and opener: • AL WA YS disable locks before installing and operating the opener . • ONL Y operate garage door opener at 120V , 60 Hz to avoid malfunction and damage.
Safety Reversing Sensor Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.
5 Straight Door Arm Section Curved Door Arm Section Safety Labels and Literature Header Bracket U P C E IL IN G M O U N T O N L Y Belt Cap Retainer 2-Conductor Bell Wire White & White/Red Light Le.
6 ASSEMBL Y STEP 1 Attach the T -Rail to the Motor Unit To av oid installation difficulties, do not run the garage door opener until instructed to do so. •R emov e the two washered bolts mounted in top of motor unit. • Align T -rail and styrof oam over sproc ket.
7 ASSEMBL Y STEP 3 Attach the Belt Cap Retainer •P osition the belt cap retainer ov er the motor unit sprock et so the two holes in cap align with the two holes in mounting plate. Attach with #8x3/8" hex screws pro vided. Y ou have no w finished assembling y our garage door opener .
8 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures va r y according to garage door types. Follo w the instructions which apply to your door . SECTIONAL DOOR AND ONE-PIECE DOOR WITH TRA CK 1. Close the door and mark the inside vertical centerline of the garage door .
9 Header Wall Vertical Centerline Vertical Centerline of Garage Door 2x4 Unfinished Ceiling 2x4 OPTIONAL CEILING MOUNT FOR HEADER BRACKET Structural Supports ONE-PIECE DOOR WITHOUT TRA CK 1. Close the door and mark the inside vertical centerline of your garage door .
10 INST ALLA TION STEP 2 Install the Header Bracket Y ou can attach the header brack et either to the wall abov e the garage door , or to the ceiling. F ollow the instructions which will work best for y our par ticular requirements. Do not install the header brac ket o ver drywall.
Clevis Pin 5/16"x2-3/4" Ring Fastener 11 INST ALLA TION STEP 3 Attach the T -Rail to the Header Bracket •P osition the opener on the garage floor below the header brac ket. Use packing material as a protectiv e base. NO TE: If the door spring is in the wa y y ou’ll need help .
12 ONE-PIECE DOOR WITHOUT TRA CK •W ith the door fully open and parallel to the floor , measure the distance from the floor to the top of the door . • Using a stepladder as a suppor t, raise the top of the opener to this height. • The top of the door should be le vel with the top of the motor unit.
13 INST ALLA TION STEP 5 Hang the Opener Tw o representative installations are sho wn. Y ours ma y be different. Hanging brack ets should be angled (Figure 1) to provide rigid suppor t. On finished ceilings (Figure 2), attach a sturdy metal brac ket to structural suppor ts before installing the opener .
14 To prevent possible SERIOUS INJURY or DEA TH from electrocution: • Be sure power is not connected BEFORE installing door control. • Connect ONL Y to 24 VOL T low voltage wires.
15 INST ALLA TION STEP 7 Install the Lights • Press the release tabs on both sides of lens. Gently rotate lens back and do wnward until the lens hinge is in the fully open position. Do not remov e the lens. • Install up to a 100 watt maximum light b ulb in each sock et.
16 INST ALLA TION STEP 9 Electrical Requirements To av oid installation difficulties, do not run the opener at this time. To reduce the r isk of electr ic shock, y our garage door opener has a grounding type plug with a third g rounding pin. This plug will only fit into a grounding type outlet.
17 Invisible Light Beam Protection Area Sensor Beam 6" max. above floor Sensor Beam 6" max. above floor F acing the door fr om inside the garage INST ALLA TION STEP 10 Install The Protector System ® The safety rever sing sensor must be connected and aligned correctly bef ore the garage door opener will move in the do wn direction.
18 FLOOR MOUNT (RIGHT SIDE) WALL MOUNT (RIGHT SIDE) DOOR TRACK MOUNT (RIGHT SIDE) Indicator light Lens Lip Sensor Bracket Door Track Sensor Bracket Extension Bracket (See Accessories) Lens Indicator l.
19 Carriage bolt 1/4"-20x1/2" Lens Wing nut Figure 4 MOUNTING AND WIRING THE SAFETY SENSORS • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor . Use wing nuts to fasten sensors to brac kets , with lenses pointing toward each other across the door .
20 INST ALLA TION STEP 11 Fasten the Door Bracket F ollow instructions which apply to your door type as illustrated below or on the f ollowing page. A horizontal reinfor cement brace should be long enough to be secured to two or three vertical supports.
21 Header Wall Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not provided) to fasten door bracket.
22 INST ALLA TION STEP 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONL Y • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley .
23 Nuts 5/16"-18 Lock Washers 5/16" Ring Fastener Straight Arm Bolts 5/16"-18x7/8 Door Bracket Clevis Pin 5/16"x1-1/4" Curved Door Arm Figure 4 Door Arm Door Arm Connector Hol.
24 ADJUSTMENT STEP 1 Adjust the UP and DOWN T ravel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down. T o operate the opener , press the Door Control push bar . Run the opener through a complete travel cycle.
ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door . If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSL Y INJURED or KILLED by a closing garage door . • Safety reversal system MUST be tested ever y month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
OPERA TION Using Y our Garage Door Opener Y our Security ✚ opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Y our opener will operate with up to eight Security ✚ remote controls and one Security ✚ Keyless Entry System.
B) T o operate one door using all three buttons on the hand-held remote: Y ou may program the remote to open the door with the large button, close it with the middle button, and stop the door ’s movement with the third button. NOTE: If remote is already programmed, you must first erase all codes.
CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re- adjustments, particularly during the first year of operation. Pages 24 and 25 refer to the limit and force adjustments.
30 Having a Problem? (Continued) 6. The garage door opens and closes by itself: • Be sure that all remote control push buttons are off. • Remove the bell wire from the door control terminals and operate from the remote only .
*3-Channel Remotes If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ 3-channel remote or mini-remote can be programmed to operate other Security ✚ garage door openers.
1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 2. While holding the ENTER button, press and hold the LIGHT button on the Multi-Function Door Control.
7 10 11 5 N O T IC E U P C E I L I N G M O U N T O N L Y 8 6 1 4 3 2 LO C K L IG H T 9 12 2 5 6 1 3 7 R A IL G R E A S E 8 4 Installation Parts 33 REP AIR P ARTS Rail Assembly Parts KEY P ART NO.
2 10 8 13 14 15 19 4 5 3 9 16 12 7 18 11 17 1 6 6 7 DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSY. Grey Wire Yellow Wire (Up) Contact Center Limit Contact Drive Gear KEY P ART NO. NO. DESCRIPTION 1 41A4371 Belt cap retainer 2 41A4885-5 Gear and sprocket assy .
LOCK LIGHT C LO S E D O P E N ACCESSORIES 974LM 970LM 995LM 2778BD 41A5281 1702LM Outside Quick Release: Required for a garage with NO access door . Enables homeowner to open garage door manually from outside by disengaging trolley . 8 Foot Complete Rail: T o allow an 8 foot door to open fully .
© 2003, The Chamberlain Group, Inc. 1 14A2537G All Rights Reserved Printed in Mexico LIFTMASTER SERVICE IS ON CALL OUR LARGE SERVICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SERVICE INFORMA TION IS AS NEAR AS YOUR TELEPHONE SEVEN DA YS A WEEK.
デバイスChamberlain 2280-267の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain 2280-267をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain 2280-267の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain 2280-267の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain 2280-267で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain 2280-267を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain 2280-267の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain 2280-267に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain 2280-267デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。