Chamberlainメーカー3575K 4 HPvの使用説明書/サービス説明書
ページ先へ移動 of 36
The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1 196 www .liftmaster .com GARAGE DOOR OPENER Models 3575 3/4 HP 3575-267D 3/4 HP 3575K 3/4 HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation.
2 Introduction 2-5 Safety symbol and signal word review ........................2 Preparing your garage door ........................................3 T ools needed ...............................................................3 Planning ............
3 T o prevent damage to garage door and opener: • AL WA YS disable locks BEFORE installing and operating the opener . • ONL Y operate garage door opener at 120V , 60 Hz to avoid malfunction and damage.
FINISHED CEILING Support bracket & fastening hardware is required. See page 12. Slack in chain tension is normal when garage door is closed. Safety Reversing Sensor Header W all Access Door Safety.
5 Y our garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below . Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
W ashered Bolt 5/16"-1 8 x1/2" Styrofoam T -rail Hole Lock Nu t 6 ASSEMBL Y STEP 1 Attach the T -Rail to the Motor Unit T o avoid installation difficulties, do not run the garage door opener until instructed to do so. • Remove the bolt and lock nut from the top of the motor unit.
7 Lock W asher T o Tighten Outer Nut Inner Nut T rolley Chain Base of Rail 1/2" (13 mm) T o Tighten Inner Nut Outer Nut Mid Length of Rail INST ALLA TION ASSEMBL Y STEP 3 Tighten the Chain • Spin the inner nut and lock washer down the trolley threaded shaft, away from the trolley .
8 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door . 1. Close the door and mark the inside vertical centerline of the garage door .
9 INST ALLA TION STEP 2 Install the Header Bracket Y ou can attach the header bracket either to the wall above the garage door , or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall.
10 Clevis Pin 5/16"x2-3/4" Ring Fastener INST ALLA TION STEP 3 Attach the Rail to the Header Bracket • Position the opener on the garage floor below the header bracket. Use packing material as a protective base. NOTE: If the door spring is in the way you’ll need help.
11 ONE-PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder . Y ou will need help at this point if the ladder is not tall enough. • Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
Meas u re Distance Lag Scre w s 5/16"-18x1-7/8" Str u ct u ral S u pports Bracket (Not Pro v ided) Lag Scre w s 5/16"-18x1-7/8" (Not Pro v ided) Bolt 5/16"-18x7/8" Lock W.
KG 1 3 9 7 5 KG 1 3 9 7 5 13 INST ALLA TION STEP 6 Install the Door Control Locate door control within sight of the door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of the door and door hardware.
14 INST ALLA TION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install up to a 100 watt maximum light bulb in each socket.
15 INST ALLA TION STEP 9 Electrical Requirements T o avoid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
16 Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor Sensor Beam 6" (15 cm) max. above floor Facing the door from inside the garage INST ALLA TION STEP 10 Install .
17 DOOR TRACK MOUNT (RIGHT SIDE) Indicator Light Lens Lip Sensor Bracket Door Track FLOOR MOUNT (RIGHT SIDE) WALL MOUNT (RIGHT SIDE) Indicator Light Sensor Bracket Lens Extension Bracket (See Accessor.
In v isi b le Light Beam Protection Area Sensor Sensor Connect Wire to Opener Q u ick-Connect T erminals Bell Wire Bell Wire Finished Ceilin g Q u ick-Connect T erminals 3.
19 Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit.
20 Header W all Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" ( N ot Provided) to fasten door bracket.
21 INST ALLA TION STEP 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONL Y • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley .
22 ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
23 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSL Y INJURED or KILLED by a closing garage door . • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the right panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door . If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSL Y INJURED or KILLED by a closing garage door . • Safety reversal system MUST be tested ever y month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
Using Y our Garage Door Opener Y our Security ✚ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes. Y our opener will operate with up to eight Security ✚ ® remote controls and one Security ✚ ® Keyless Entry System.
T o Open the Door Manually The door should be fully closed if possible. Pull down on the emergency release handle and lift the door manually . T o reconnect the door to the opener , press the door control push bar . The lockout feature prevents the trolley from reconnecting automatically .
CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments.
29 HA VING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • V erify the safety sensors are properly installed, aligned and free of any obstructions.
Safety Sensor Bell Wire LED or Diagnostic LED "Learn" Button KG 1 3 9 7 5 KG 1 3 9 7 5 Diagnostics Located On Motor Unit 30 Installed Safety Sensor Y our garage door opener is programmed with self-diagnostic capabilities.
*3-Button Remotes If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ ® 3-Button remote or compact remote can be programmed to operate other Security ✚ ® garage door openers.
KG 1 3 9 7 5 KG 1 3 9 7 5 1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 2. While holding the ENTER button, press and hold the LIGHT button on the Motion Detecting Door Control.
1 3 4 5 6 2 33 REP AIR P ARTS Rail Assembly Parts KEY P ART NO. NO. DESCRIPTION 1 4A1008 Master link kit 2 41A4813 Chain pulley bracket 3 41A3489 Complete trolley assembly 4 1707LM One-piece rail 5 41.
Motor Unit Assembly Parts 34 DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSY . Grey Wire Y ellow Wire (Up) Contact Center Limit Contact Drive Gear 2 4 3 1 15 19 8A 17 5 18 9 10 16 14 13 12 6 6 11 8B 8C 7 7 KEY P ART NO.
35 LOCK L IG HT CLOS ED O PE N ACCESSORIES 370LM 1708LM 41A5281 1702LM Outside Quick Release: Required for a garage with NO access door . Enables homeowner to open garage door manually from outside by disengaging trolley . 8 Foot (2.4 m) Complete Rail: T o allow an 8 foot (2.
© 2007, The Chamberlain Group, Inc. 1 14A3086D All Rights Reserved LIFTMASTER ® SER VICE IS ON CALL OUR LARGE SERVICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SERVICE INFORMA TION IS AS NEAR AS YOUR TELEPHONE. SIMPL Y DIAL OUR TOLL FREE NUMBER: 1-800-528-9131 www .
デバイスChamberlain 3575K 4 HPvの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain 3575K 4 HPvをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain 3575K 4 HPvの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain 3575K 4 HPvの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain 3575K 4 HPvで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain 3575K 4 HPvを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain 3575K 4 HPvの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain 3575K 4 HPvに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain 3575K 4 HPvデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。