The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1 196 www .liftmaster .com GARAGE DOOR OPENER Model 3585S 3/4 HP For Residential Use Only Owner’ s Manual ■ Please read this manual and the enc losed safety materials carefully! ■ Fasten the man ual near the garage door after installation.
2 Introduction 2-5 Safety symbol and signal word review . . . . . . . . . . . . . . . 2 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3 Tools needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Planning .
3 To prevent damage to garage door and opener: • ALWAYS disable locks BEFORE installing and operating the opener. • ONLY operate garage door opener at 120V, 60 Hz to avoid malfunction and damage. To prevent possible SERIOUS INJURY OR DEATH: • ALWAYS call a trained door systems technician if garage door binds, sticks, or is out of balance.
FINISHED CEILING Support bracket & fastening hardware is required. See page 12. Safety Reversing Sensor Header Wa ll Access Door Safety Reversing Sensor Gap between floor and bottom of door must n.
5 Y our garage door opener is packaged in two cartons which contain the motor unit and all parts illustrated below . Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
To avoid SERIOUS damage to opener, ONLY use bolts/ fasteners mounted in top of motor unit. ASSEMBL Y STEP 1 Attach the Rail to the Motor Unit T o av oid installation difficulties, do not run the garage door opener until instructed to do so. • Remove the bolt and lock nut from the top of the motor unit.
7 INST ALLA TION IMPOR T ANT INST ALLA TION INSTR UCTIONS T o reduce the risk of SEVERE INJUR Y or DEA TH: WARNING WARNING WARNING WARNING 1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. 2. Install garage door opener ONLY on properly balanced and lubricated garage door.
8 INST ALLA TION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door . 1. Close the door and mark the inside vertical centerline of the garage door .
Lag Screw 5/16"-9x1-5/8" HARD WARE SHO WN ACTU AL SIZE Lag Screws 5/16"-9x1-5/8" Highest Point of Garage Door T ravel V ertical Centerline of Garage Door Header W all Garage Door UP CEILING MOUNT ONL Y W all Mounting Holes Optional W all Mounting Holes The nail hole is for positioning only .
Header Bracket Belt Pulley Bracket Temporary Support Header Wall Garage Door Clevis Pin 5/16"x2-3/4" Ring Fastener Header Bracket Belt Pulley Bracket Rail Clevis Pin 5/16"x2-3/4" R.
11 ONE-PIECE DOOR WITHOUT TRACK A 2x4 on its side is convenient for setting an ideal door-to-rail distance. • Remove foam packaging. • Raise the opener onto a stepladder. You will need help at this point if the ladder is not tall enough. • Open the door all the way and place a 2x4 on its side on the top section of the door beneath the rail.
12 INST ALLA TION STEP 5 Hang the Opener Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings (Figure 2 and Figure 3), attach a sturdy metal bracket to structural supports before installing the opener.
13 INST ALLA TION STEP 6 Install the Door Control Locate door control within sight of door, at a minimum height of 5' (1.5 m) where small children cannot reach, away from moving parts of door and door hardware. If installing into drywall, drill 5/32" holes and use the anchors provided.
14 INST ALLA TION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install a 100 watt maximum light bulb in each socket.
15 INST ALLA TION STEP 9 Electrical Requirements T o av oid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
16 Facing the door fr om inside the garage INST ALLA TION STEP 10 Install The Protector System ® The safety rever sing sensor must be connected and aligned correctly bef ore the garage door opener will move in the do wn direction.
17 INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the floor. They may be installed in one of three ways, as follows.
Invisible Light Beam Protection Area Safety Reversing Sensor Safety Reversing Sensor Connect Wire to Opener Quick-Connect Terminals Bell Wire Bell Wire Finished Ceiling 1. Strip wire 7/16" (11 mm) 2. Twist like colored wires together 7/16" (1 1 mm) Quick-Connect T erminals 3.
19 Fiberglass, aluminum or lightweight steel garage doors WILL REQUIRE reinforcement BEFORE installation of door bracket. Contact your door manufacturer for reinforcement kit. INSTALLATION STEP 11 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page.
Header Wall Vertical Centerline of Garage Door Finished Ceiling Optional Placement of Door Bracket Header Bracket Door Bracket 2x4 Support For a door with no exposed framing, or for the optional installation, use lag screws 5/16"x1-1/2" (Not Provided) to fasten door bracket.
21 INSTALLATION STEP 12 Connect Door Arm to Trolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONLY Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley.
22 ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 4: • Fasten the straight and curved door arm sections together to the longest possible length (with a 2 or 3 hole overlap). • With the door closed, connect the straight door arm section to the door bracket with the 5/16"x1-1/4" clevis pin.
23 ADJUSTMENT STEP 1 Adjust the UP and DOWN Travel Limits Limit adjustment settings regulate the points at which the door will stop when moving up or down. To operate the opener, press the door control push bar. Run the opener through a complete travel cycle.
24 ADJUSTMENT STEP 2 Adjust the Force Force adjustment controls are located on the back panel of the motor unit. Force adjustment settings regulate the amount of power required to open and close the door. If the forces are set too light, door travel may be interrupted by nuisance reversals in the down direction and stops in the up direction.
25 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
26 OPERA TION IMPOR T ANT SAFETY INSTR UCTIONS T o reduce the risk of SEVERE INJUR Y or DEA TH: Using Y our Garage Door Opener Y our Security ✚ ® opener and hand-held remote control have been factory-set to a matching code which changes with each use, randomly accessing over 100 billion new codes.
27 Using the W all-Mounted Door Control THE SMART CONTR OL P ANEL TM Press the push bar to open or close the door . Press again to reverse the door during the closing cycle or to stop the door while it's opening.
The 3V2016 lithium batteries for the opener and LED lights (marked “LED and Opener Battery”) should last 5 years. The 3V2450 lithium battery for the proximity lighting (marked “Proximity Battery”) should last 1-2 years. T o replace the batteries, remove the two screws and open the remote control housing.
29 CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. Pages 23 and 24 refer to the limit and force adjustments.
30 HAVING A PROBLEM? 1. My door will not close and the light bulbs blink on my motor unit: The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. • Verify the safety sensors are properly installed, aligned and free of any obstructions.
Bell Wire Safety Reversing Sensor KG 1 3 9 7 5 KG 1 3 9 7 5 Diagnostics Located On Motor Unit "Learn" Button LED or Diagnostic LED Installed Safety Reversing Sensor Diagnostic Chart 31 Your garage door opener is programmed with self-diagnostic capabilities.
32 Meaning: This message will appear if the Safety Re versing Sensors are out of alignment, if they are bloc ked or if the wiring is disconnected. T o clear messa g e from Smart Control P anel™ do the following: • Check to see that area is clear between the Safety Reversing Sensors.
33 *3-Button Remotes If provided with your garage door opener, the large button is factory programmed to operate it. Additional buttons on any Security ✚ ® 3-Button remote or compact remote can be programmed to operate other Security ✚ ® garage door openers.
34 To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON USING THE SMART CONTROL PANEL TM 1. Press the PROG <Learn> button on the Smart Control Panel TM .
8 11 12 6 N OT ICE U P C E I L I N G M O U N T O N L Y 9 7 1 5 10 13 14 L O C K L IGH T 3 4 2 Installation Parts 2 5 6 1 3 7 8 4 Rail Assembly Parts 35 REP AIR P AR TS KEY PART NO.
36 Motor Unit Assembly Parts DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSEMBL Y Grey Wire Y ellow Wire (Up) Contact Center Limit Contact Drive Gear 2 4 3 1 15 19 8 17 5 18 9 10 16 14 13 12 6 6 11 7 7 7 7 KEY PART NO.
37 ACCESSORIES 370LM 41A5281 1702LM Outside Quick Release: Required for a garage with NO access door . Enables homeowner to open garage door manually from outside by disengaging trolley . 377LM Extension Brackets: (Optional) For safety sensor installation onto the wall or floor .
38 NOTES.
39 NOTES.
© 2008, The Chamberlain Group, Inc. 114A3616 All Rights Reserved LIFTMASTER ® SER VICE IS ON CALL OUR LARGE SER VICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SER VICE INFORMA TION IS AS NEAR AS Y OUR TELEPHONE. SIMPL Y DIAL OUR T OLL FREE NUMBER: 1-800-528-9131 www .
デバイスChamberlain 3585S 3/4 HPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain 3585S 3/4 HPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain 3585S 3/4 HPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain 3585S 3/4 HPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain 3585S 3/4 HPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain 3585S 3/4 HPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain 3585S 3/4 HPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain 3585S 3/4 HPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain 3585S 3/4 HPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。