Owner’ s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation. ■ The door WILL NOT CLOSE unless The Protector System ® and cable tension monitor are connected and properly aligned.
2 INTRODUCTION Safety Symbol Review and Signal Wor d Review When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them.
Safety Reversing Sensor Safety Reversing Sensor T orsion Spring Motor unit W all-mounted Control Console Access Door Gap between floor and bottom of door must not exceed 1/4" (6 mm). Power Door Lock Cable T ension Monitor Remote Light Drum 3 Planning Survey your garage area to see if any of the conditions below apply to your installation.
4 Preparing your Garage Door Before you begin: • Disable locks. • Remove any ropes connected to garage door . • Complete the following test to make sure your garage door is balanced and is not sticking or binding: 1. Lift the door about halfway as shown.
5 2-Cond u ctor Bell W ire W hite & W hite/Red Safety La b els and Literat u re Remote Control V isor Clip Mo u nting Bracket SECURITY ✚ ® 3-B u tton Remote Control (1) (2) Safety Re v ersing S.
ASSEMBL Y STEP 1 Attach the Collar to the Motor Unit T o avoid installation difficulties, do not run the garage door opener until instructed to do so. • Loosen the collar screws. • Attach collar to either the left or the right side of the motor unit.
7 INST ALLA TION INST ALLA TION STEP 1 Position the Opener 1. Close the garage door completely . 2. Slide the opener with collar over the end of the torsion bar . Check to make sure bracket is located on a solid surface such as wood, concrete or door/flag bracket.
8 Staples Lock Scre w 1/4-20 x 1/2" (2) HARDW ARE SHOWN ACTUAL SIZE Approx. 3" (7.6 cm) Lock T emplate Roller Garage Door T rack TOP DRILL 5/16" DRILL 3/4" DRILL 5/16" 132A250.
9 W HT/GR N T o release w ire, p u sh in ta b w ith scre w dri v er tip Ca b le T ension Monitor 7/16" (1 1mm) Strip w ire 7/16" (1 1mm) W HT/GR N Ca b le T ension Monitor Ca b le T ension M.
10 INST ALLA TION STEP 5 Install the Control Console Locate control console within sight of the door at a minimum height of 5 feet (1.5 m) where small children cannot reach, and away from moving parts of the door and door hardware. The installation surface must be smooth and flat.
11 INST ALLA TION STEP 6 Install Remote Light The remote light is designed to plug directly into a standard 120V outlet. 1. Install the hinge and latch clips. Clips slide in between the metal plate and the plastic housing on each side of the light base (Figure 1).
12 INST ALLA TION STEP 7 Electrical Requirements T o avoid installation difficulties, do not run the opener at this time. T o reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
13 INST ALLA TION STEP 8 Mount the Battery Backup Unit (BBU) (not provided) If the optional 475LM battery backup unit is part of this installation it should be installed at this time. • The BBU can be mounted to either the ceiling or a wall within 3' (.
14 In v isi b le Light Beam Protection Area Safety Re v ersing Sensor 6" (15 cm) max. a b o v e floor Safety Re v ersing Sensor 6" (15 cm) max.
15 DOOR TRACK MOUNT (RIGHT SIDE) Indicator Light Lens Lip Sensor Bracket Door Track FLOOR MOUNT (RIGHT SIDE) WALL MOUNT (RIGHT SIDE) Indicator Light Sensor Bracket Lens Extension Bracket (See Accessor.
16 In v isi b le Light Beam Protection Area S enso r Senso r Safety Re v ersing Sensor Bell W ire Bell W ire Motor u nit Safety Re v ersing Sensor Po w er Door Lock Q u ick-Connect Terminals W HT/BLK .
17 T o prevent damage to vehicles, be sure fully open door provides adequate clearance. WARN ING CAUTION WARN ING WARN ING BLACK PURPLE Push and hold until the door is at desired UP position Figure 2 .
18 ADJUSTMENT STEP 2 Setting the Force The force setting button is located on the front panel. The force setting measures the amount of force required to open and close the door . 1. Locate the purple button on the unit (Figure 1). 2. Push the purple button twice to enter unit into Force Adjustment Mode (Figure 2).
19 ADJUSTMENT STEP 3 T est the Safety Reversal System TEST • With the door fully open, place a 1-1/2" (3.8 cm) board (or a 2x4 laid flat) on the floor , centered under the garage door . • Operate the door in the down direction. The door must reverse on striking the obstruction.
20 ADJUSTMENT STEP 5 T est Cable T ension Monitor If your cable tension monitor has been activated the LED will blink 9 times. ADJUSTMENT STEP 6 T est Power Door Lock TEST • With the door fully closed, the power door lock bolt should be protruding through the track.
21 OPERA TION Using Y our Garage Door Opener Y our LiftMaster Security ✚ ® opener and hand-held remote control have been factory programmed to a matching code which changes with each use, randomly accessing over 100 billion new codes.
22 Using the W all-Mounted Control Console THE MOTION DETECTING CONTROL CONSOLE Press the push bar to open or close the door . Press again to reverse the door during the closing cycle or to stop the door while it's opening.
23 CARE OF YOUR OPENER MAINTENANCE SCHEDULE Once a Month • Manually operate door . If it is unbalanced or binding, call a trained door systems technician. • Check to be sure door opens & closes fully . Adjust limits and/or force if necessary (See Adjustment Steps 1 and 2).
24 Having a Problem? (Continued) 5. The garage door opens and closes by itself: • Be sure that all remote control push buttons are off. • Remove the bell wire from the door control terminals and operate from the remote only .
25 Y our garage door opener is programmed with self- diagnostic capabilities. The “Learn” button/diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Chart below . Diagnostic Char t Symptom: One or both of the Indicator lights on the safety reversing sensors do not glow steady .
26 *3-Button Remote If provided with your garage door opener , the large button is factory programmed to operate it. Additional buttons on any Security ✚ ® 3-Button remote or mini-remote can be programmed to operate other Security ✚ ® garage door openers.
27 1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 2. While holding the ENTER button, press and hold the LIGHT button on the Motion Detecting Control Console.
28 1. Press the “learn button” on light until LED comes ON. 2. Activate the garage door using the hand-held remote, wall control or keyless entry .
29 7 10 11 6 5 NO T IC E 8 1 4 2 3 9 12 L O C K L IG H T 13 14 Installation Parts REP AIR P ARTS KEY P ART NO. NO. DESCRIPTION 1 98LM Motion detecting control panel 2 373W 3-Button remote control 3 10.
30 1 2 3 4 5 6 KEY P ART NO. NO. DESCRIPTION 1 41DJ001 Logic board complete with plate 2 41A61 18 Absolute Encoder System 3 41C168 T ransformer KEY P ART NO.
31 L O C K L I G H T CL OS E D O P E N ACCESSORIES 370LM 41A5281 377LM Extension Brackets: (Optional) For safety reversing sensor installation onto the wall or floor . Keyless Entry with Security ✚ ® : Enables homeowner to operate garage door opener from outside by entering a password on a specially designed keyboard.
LIFTMASTER ® SER VICE IS ON CALL OUR LARGE SERVICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SERVICE INFORMA TION IS AS NEAR AS YOUR TELEPHONE SEVEN DA YS A WEEK. SIMPL Y DIAL OUR T OLL FREE NUMBER: 1-800-528-2817 HOURS: (Central Standard Time) 6:00 A.
デバイスChamberlain 3800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain 3800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain 3800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain 3800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain 3800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain 3800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain 3800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain 3800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain 3800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。