The Chamberlain Group, Inc. A DUCHOSSOIS ENTERPRISE 845 Larch Avenue Elmhurst, Illinois 60126-1 196 Complies with UL 325 Regulations effective January 1, 1993.
Start by reviewing these important safety alert symbols 2 Contents Page A review of safety alert symbols ..................................2 You'll need tools ...........................................................3 Safety information regarding garage door locks and ropes .
Pliers Wire Cutters Claw Hammer Hack Saw Screwdriver Adjustable End Wrench 1/2" and 7/16" Sockets and Wrench Drill Tape Measure 2 1 Stepladder Pencil 3/16", 5/16" and 5/32&qu.
4 Safety Reversing Sensor Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, steel, aluminum, door with glass panels, etc.). See page 24 for details. Support bracket & fastening hardware is required. See page 17.
Safety Reversing Sensor FINISHED CEILING Support bracket & fastening hardware is required. See page 17. Slack in Belt Tension is Normal When Garage Door is Closed Safety Reversing Sensor Header Wall Access Door Gap between floor and bottom of door must not exceed 1/4".
Multi-Function Remote Control Transmitter 2-Conductor Bell Wire White & White/Red Trolley Door Bracket Door Bracket Plate Header Bracket Hanging Brackets Belt Curved Door Arm Section Straight Door.
Lock Washer 5/16" (4) Nut 5/16"-18 (6) Clevis Pin 5/16"x2-3/4" (1) NOTICE Handle Insulated Staples (10) Assembly Hardware Installation Hardware Dry Wall Anchors (2) Cle.
8 Assembly Step 1 Assemble the T -rail & Attach the Belt Pulley Bracket T-RAIL BACK (TO OPENER) T-RAIL FRONT (TO DOOR) Belt pulley bracket attaches to FRONT END of T-rail T-rail (End Section) T-ra.
Assembly Step 2 Install the T rolley on the T -rail 9 • As a temporary stop, insert a screwdriver into the hole in the front end of the T-rail. • Slide the trolley assembly along the rail to the screwdriver stop. If trolley hits against any nuts on the T-rail, the bolts and nuts were attached from the wrong side and must be repositioned.
Assembl y Step 4 Install the Belt & Set the Belt T ension Serious injury can result if fingers become entangled in moving opener sprocket. Attach belt cap retainer securely. Never operate opener while your hand is near the opener sprocket. The Chamberlain Group, Inc.
Hex Screws #8x3/8" Belt Cap Retainer Opener Sprocket Mounting Plate Belt Assembly Step 5 Attach the Belt Cap Retainer IMPORT ANT INST ALLA TION INSTRUCTIONS T o reduce the risk of severe injury or death to persons: 1. READ AND FOLLOW ALL INST ALLA TION INSTRUCTIONS.
• Open your door to the highest point of travel as shown. Draw an intersecting horizontal line on the header wall 2" above the high point. This height will provide travel clearance for the top edge of the door. Header Wall Ceiling Track Highest Point of Travel Door 2" 12 Proceed to Step 2, page 14.
Header Wall Vertical Centerline Vertical Centerline of Garage Door 2x4 Unfinished Ceiling Structural Supports 2x4 OPTIONAL CEILING MOUNT FOR HEADER BRACKET • Close the door and mark the inside vertical centerline of your garage door.
Lag Screws 5/16"x9x1-5/8" Highest Point of Travel (of Garage Door) Vertical Center Line Header Wall Garage Door Mounting New Header Bracket 10/16/91 - 10/26/91 - 4/5/.
Header Bracket Belt Pulley Bracket Temporary Support Header Wall Garage Door The Chamberlain Group, Inc. Liftmaster Synchro Drive Attach Tee Rail to Header Brac k 5/16/92 T-rail Clev.
Installation Step 4 Position the Opener Follow instructions which apply to your door type as illustrated. To prevent damage to steel, aluminum, fiberglass or glass panel doors, do not rest the opener on the door without using a 2x4.
Installation Step 5 Hang the Opener Two representative installations are shown. Yours may be different. Hanging brackets should be angled, Figure 1, to provide rigid support. On finished ceilings, Figure 2, attach a sturdy metal bracket to structural supports before installing the opener.
Opener Terminal Screws Antenna Right Panel of Opener Multi-Function Door Control Panel Multi-Function Door Control Panel Terminal Screws RED WHITE The Chamberlain Group, Inc.
• Install a 75 watt maximum light bulb in each socket. The lights will turn ON and remain lit for approximately 4-1/2 minutes when power is connected. Then the lights will turn OFF. • If the bulbs burn out prematurely due to vibration, replace them with "Garage Door Opener" bulbs.
To prevent electrocution, remove power from the garage door opener and from the circuit you plan to use for the permanent connection. To reduce the risk of electric shock, your garage door opener has a grounding type plug with a third grounding pin. This plug will only fit into a grounding type outlet.
Without a properly working safety reversing sensor, persons (particularly children) could be injured or killed by a closing garage door. Read and follow all instructions. To protect small children, install the safety reversing sensor so that the beam will be no higher than 4"-6" above the garage floor.
1/4x1-1/2" Lag Screw #10-32x3/8" Screw 1/4"-20 Lock Nut #10x32 Lock Nut Staples 1/4"-20x1/2" Carriage Bolts Installation Step 10 Install th.
Invisible Light Beam Protection Area Sensor Sensor Connect Wire to Opener Terminals The Chamberlain Group, Inc. Attaching Sensor to "C" Wrap and Wires to Operator Liftmaster Sync.
Installation Step 1 1 Fasten Door Bracket Follow instructions which apply to your door type as illustrated below or on page 25. To prevent damage to steel, aluminum, fiberglass or glass panel doors, always reinforce the inside of the door both vertically and horizontally with an angle iron.
Door Bracket Top of Door (Inside Garage) Carriage Bolt 5/16"-18x2-1/2" Optional Placement Lock Washer 5/16" Nut 5/16"-18 Horizontal and vertical reinforcement is needed for lightweight garage doors (fiberglass, aluminum, steel, door with glass panel, etc.
Installation Step 12 Connect Door Arm to T rolley Follow instructions which apply to your door type as illustrated below and on page 27. Make sure garage door is fully closed. Pull the manual release handle to disconnect the outer trolley from the inner trolley.
Door Arm to Trolley 1 pc 1/96 Nuts 5/16"-18 Lock Washers 5/16" Ring Fastener Straight Arm Screws 5/16"-18x7/8 Door Bracket Clevis Pin 5/16"x1-1/4" C.
Adjustment Step 1 Adjust the UP and DOWN Limits Do not make any limit adjustments until the Safety Reversing Sensors are completely installed. 28 Limit adjustment settings regulate the points at which the door will stop when moving up or down. The door will stop in the up direction if anything interferes with door travel.
Adjustment Step 2 Adjust the Force Too much force on the door will interfere with the proper operation of the safety reverse system. The door might not reverse properly when required and could seriously injure or kill someone under it. Do not increase the force beyond the minimum amount required to close the door.
Adjustment Step 4 T est the Safety Reverse System Test: • Place a one-inch board (or a 2x4 laid flat) on the floor, centered under the garage door. • Operate the door in the down direction. The door must reverse on striking the obstruction. Adjustment: If the door stops on the obstruction, it is not traveling far enough in the down direction.
Once a Month Manually operate door. If it is unbalanced or binding, call for professional garage door service. Check to be sure door opens and closes fully. Adjust limits and/or force if necessary. (See pages 28 and 29.) Repeat the safety reverse test.
To open the door manually: The door should be fully closed if possible. Pull down on the manual release handle and lift the door manually. To reconnect the door to the opener, press the Door Control push bar. 32 Activate the opener with any of the following: • The Remote Control Transmitter.
Garage Door Opener (With "Smart" Button) "Smart" Button Indicator Light END PANEL KG KG 1 3 9 7 5 1 3 9 7 5 1 2 3 Children operating or playing with a garage door opener can injure themselves or others. The garage door could close and cause serious injury or death.
1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.) 2. Have you disabled all door locks? Review installation instruction warnings on Page 11.
Having a Problem? (continued) Situation Probable Cause & Solution The opener strains or maximum force is needed to operate the door: The door may be out of balance or the springs are broken. Close the door and use the manual release rope and handle to disconnect the trolley.
NOTICE LIGHT LOCK 12VDC 2 9 UP CEILING MOUNT ONLY 10 11 12 16 1 3 4 5 6 8 7 15 14 13 2 1 3 3 4 5 10 5 RAIL GREASE NO. 83A4 8 6 7 9 Repair Parts Rail Assembly Parts Installation Parts 36 KEY PART NO.
Repair Parts Opener Assembly Parts 2 12 10 15 4 3 DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSY. Grey Wire Yellow Wire (Up) Contact Center Limit Contact Drive Gear 11 5 6 7 9 8 9 8 20 14 13 16 1 3 18 19 17 5 KEY P ART NO. NO. DESCRIPTION 1 41A4371 Belt cap retainer 2 41A4885 Gear and sprocket assy .
1 2 3 4 5 6 7 8 9 0 ENTER LIGHT LOCK Accessories A vailable for your Opener 853CB 872CB 760CB 740CB 7702CB Multi-Function Standard Size Remote Control: Includes visor clip. Keyless Entry: Enables homeowner to operate garage door opener from outside by entering code on specially designed keyboard.
Index Access Door/Outside Quick Release Accessory ............................................................................................4, 5 Electrical Safety Warnings .............................................................................
CHAMBERLAIN SER VICE IS ON CALL OUR LARGE SER VICE ORGANIZA TION SP ANS AMERICA INST ALLA TION AND SER VICE INFORMA TION IS AS NEAR AS Y OUR TELEPHONE SIX D A YS A WEEK. SIMPL Y DIAL OUR T OLL FREE NUMBER: 1-800-528-9131 HOURS: (Mountain Std. Time) 6 A.
デバイスChamberlain 8100Mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain 8100Mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain 8100Mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain 8100Mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain 8100Mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain 8100Mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain 8100Mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain 8100Mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain 8100Mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。