The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.chamberlain.com GARAGE DOOR OPENER Model WD822KD 1/2 HP For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Fasten the manual near the garage door after installation.
2 TABLE OF CONTENTS Introduction 2-7 Safety symbol and signal word review . . . . . . . . . . . . . . . 2 Preparing your garage door . . . . . . . . . . . . . . . . . . . . . . . 3 Tools needed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Stepladder Carpenter’s Level (optional) Tape Measure Drill Sockets and Wrench 1/2", 5/8", 7/16", 9/16" and 1/4" Pencil Wire Cutters Pliers Adjustable End Wrench Claw Hammer Screwdriver Hack Saw Drill Bits 3/16", 5/16" and 5/32" Preparing your garage door Before you begin: • Disable locks.
4 Planning Identify the type and height of your garage door. Survey your garage area to see if any of the conditions below apply to your installation. Additional materials may be required. You may fi nd it helpful to refer back to this page and the accompanying illustrations as you proceed with the installation of your opener.
5 Planning (Continued) ONE-PIECE DOOR INSTALLATIONS • Generally, a one-piece door does not require reinforcement. If your door is lightweight, refer to the information relating to sectional doors in Installation Step 11. • Depending on your door’s construction, you may need additional mounting hardware for the door bracket (Step 11).
6 Your garage door opener is packaged in one carton which contains the motor unit and all parts illustrated below. Accessories will depend on the model purchased. If anything is missing, carefully check the packing material. Parts may be stuck in the foam.
7 Hardware Inventory Separate all hardware and group as shown below for the assembly and installation procedures. ASSEMBLY HARDWARE Bolt 1/4"-20x1-3/4" (2) Lock Washer 3/8" (1) Spring/T.
8 ASSEMBLY STEP 1 Assemble the Rail & Install the Trolley To avoid installation diffi culties, do not run the garage door opener until instructed to do so. The front rail has a cut out “window” at the door end (see illustration). The hole above this window is larger on the top of the rail than on the bottom.
9 ASSEMBLY STEP 2 Fasten the Rail to the Motor Unit • Insert a 1/4"-20x1-3/4" bolt into the cover protection bolt hole on the back end of the rail as shown. Tighten securely with a 1/4"-20 lock nut. Do NOT overtighten. • Remove the two bolts from the top of the motor unit.
10 ASSEMBLY STEP 4 Install the Belt and Attach the Belt Cap Retainer 1. Pull the belt around the idler pulley and toward the trolley. The ribbed side must contact the pulley. 2. Hook the trolley connector into the retaining slot on the trolley as shown.
11 ASSEMBLY STEP 5 Set the Tension • Insert a screwdriver tip into one of the nut ring slots and brace it fi rmly against the trolley. • Place a 7/16" open end wrench on the square end. Rotate the nut about 1/4 turn until the spring releases and snaps the nut ring against the trolley.
12 INSTALLATION STEP 1 Determine the Header Bracket Location Installation procedures vary according to garage door types. Follow the instructions which apply to your door. 1. Close the door and mark the inside vertical centerline of the garage door. 2.
13 INSTALLATION STEP 2 Install the Header Bracket You can attach the header bracket either to the wall above the garage door, or to the ceiling. Follow the instructions which will work best for your particular requirements. Do not install the header bracket over drywall.
14 INSTALLATION STEP 4 Position the Opener Follow instructions which apply to your door type as illustrated. SECTIONAL DOOR OR ONE-PIECE DOOR WITH TRACK A 2x4 laid fl at is convenient for setting an ideal door-to-rail distance. • Remove foam packaging.
15 INSTALLATION STEP 5 Hang the Opener Three representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On fi nished ceilings (Figures 2 and 3), attach a sturdy metal bracket to structural supports before installing the opener.
16 To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is NOT connected BEFORE installing door control. • Connect ONLY to 24 VOLT low voltage wires.
17 INSTALLATION STEP 7 Install the Lights • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. • Install a 100 watt maximum light bulb in each socket.
18 To prevent possible SERIOUS INJURY or DEATH from electrocution or fi re: • Be sure power is NOT connected to the opener, and disconnect power to circuit BEFORE removing cover to establish permanent wiring connection. • Garage door installation and wiring MUST be in compliance with ALL local electrical and building codes.
19 INSTALLATION STEP 10 Install The Protector System ® The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR When properly connected and aligned, the sensor will detect an obstacle in the path of its electronic beam.
20 INSTALLING THE BRACKETS Be sure power to the opener is disconnected. Install and align the brackets so the sensors will face each other across the garage door, with the beam no higher than 6" (15 cm) above the fl oor. They may be installed in one of three ways, as follows.
21 MOUNTING AND WIRING THE SAFETY REVERSING SENSORS Mounting: • Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).
22 ALIGNING THE SAFETY REVERSING SENSORS • Plug in the opener. The indicator lights in both the sending and receiving eyes will glow steadily if wiring connections and alignment are correct. The sending eye amber indicator light will glow regardless of alignment or obstruction.
23 INSTALLATION STEP 11 Fasten the Door Bracket Follow instructions which apply to your door type as illustrated below or on the following page. A horizontal reinforcement brace should be long enough to be secured to two or three vertical supports. A vertical reinforcement brace should cover the height of the top panel.
24 ONE-PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page. They apply to one-piece doors also. • Center the door bracket on the top of the door, in line with the header bracket as shown. Mark either the left and right, or the top and bottom holes.
25 INSTALLATION STEP 12 Connect Door Arm to Trolley Follow instructions which apply to your door type as illustrated below and on the following page. SECTIONAL DOORS ONLY • Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the inner trolley.
26 Figure 5 Figure 6 Straight Door Arm Curved Door Arm (Groove facing out) Straight Door Arm Curved Door Arm CORRECT INCORRECT ALL ONE-PIECE DOORS 1. Assemble the door arm, Figure 5: IMPORTANT: The groove on the straight door arm MUST face away from the curved door arm.
27 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Incorrect adjustment of garage door travel limits will interfere with proper operation of safety reversal system.
28 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Too much force on garage door will interfere with proper operation of safety reversal system.
29 Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing garage door. • Safety reversal system MUST be tested every month. • If one control (force or travel limits) is adjusted, the other control may also need adjustment.
30 OPERATION IMPORTANT INSTALLATION INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: WARNING WARNING WARNING WARNING 1. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS. 2. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with garage door control push buttons or remote controls.
31 To Open the Door Manually DISCONNECT THE TROLLEY: The door should be fully closed if possible. Pull down on the emergency release handle (so that the trolley release arm snaps into a vertical position) and lift the door manually.
32 The lithium battery should produce power for up to 5 years. To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+). Dispose of old battery properly. Replace the battery with only 3V2032 coin cell batteries.
33 6. My motor unit hums briefl y: • First verify that the trolley is against the stop bolt. • Release the door from the opener by pulling the Emergency Release Rope. • Manually bring the door to a closed position. • Loosen the belt by adjusting the outer nut 4 to 5 turns.
34 Diagnostic Chart Safety reversing sensors slightly misaligned (dim or fl ashing LED). Door control or wire shorted. Safety reversing sensors wire shorted or black/white wire reversed. Safety reversing sensors wire open (broken or disconnected). OR Symptom: One or both of the Indicator lights on the safety sensors do not glow steady.
35 To Erase All Codes From Motor Unit Memory To deactivate any unwanted remote, fi rst erase all codes: Press and hold the “learn” button on motor unit until the learn indicator light goes out (approximately 6 seconds). All previous codes are now erased.
36 To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE “LEARN” BUTTON USING THE MULTI-FUNCTION DOOR CONTROL 1. Enter a four digit personal identifi cation number (PIN) of your choice on the keypad.
37 REPAIR PARTS Rail Assembly Parts KEY PART NO. NO. DESCRIPTION 1 4A1008 Master link kit 2 41C5141-2 Complete trolley assembly 3 41A5665-2 Complete rail 4 41B4103 Spring trolley nut 5 144C54 Idler pulley 6 41A5250 Full belt assembly 7 41D598-1 “U” bracket NOT SHOWN 183A163 Wear pads 8808CB 8 Foot (2.
38 KEY PART NO. NO. DESCRIPTION 1 41A4371 Belt cap retainer 2 41A4885-5 Gear and sprocket assembly. Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gea.
39 ACCESSORIES 760CB Outside Quick Release: Required for a garage with NO access door. Outdoor Key Switch: Operates the garage door automatically from outside when remote control is not handy. 7702CB 41A5281 CLLAD Extension Brackets: (Optional) For safety sensor installation onto the wall or fl oor.
CHAMBERLAIN ® SERVICE IS ON CALL OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE. SIMPLY DIAL OUR TOLL FREE NUMBER: 1-800-528-9131 www.chamberlain-diy.com For professional installation, parts and service , contact your local CHAMBERLAIN ® dealer.
デバイスChamberlain WD822KDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain WD822KDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain WD822KDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain WD822KDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain WD822KDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain WD822KDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain WD822KDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain WD822KDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain WD822KDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。