Chauvetメーカー56Cの使用説明書/サービス説明書
ページ先へ移動 of 17
3000 N 29 th Ct, Hollywood, FL 33020 U.S.A. (800) 762-1084 – (954) 929-111 5 FAX (954) 929-5 560 www.chauvetlightin g.com User Manual Snapshot Use on Dimmer Outdoor Use Sound A ctivated DMX Master/S.
CHAUVET®, 2010, Al l Rights Reserved Information and specif ications in this User M anual are subject to chan ge without notice. CHA UVET® assumes no responsibility or liability for a ny errors or inacc uracies tha t may appear in th is manual. T ABLE OF C ONTENT S 1.
1. Before You Begin 3 4/19/2010 1:08 PM 1. B EFORE Y OU B EGIN What is inc luded 1 x LEDrain™ 56 C 1 x Warranty Ca rd 1 x User M anual Unpacking Instructions Immediately upon re ceiving a fixture, carefu lly unpack the carton, check the conten ts to ensure that all parts are presen t, and hav e been re ceived in good condition.
1. Before You Begin 4 4/19/2010 1:08 PM Safety Instructions Please keep thi s User Manual for f uture consulta tion. If you sell the unit to another user , be sure that they also receive this instru ction booklet.
2. Introduction 5 4/19/2010 1:08 PM 2. I NTRODUCTION Features 3 or 7-channel DM X-51 2 LED PAR can Operating mode s: 3-channel: RG B control 7-channel: RG B, macros, run/ strobe speed , automati c/sou.
3. Setup 6 4/19/2010 1:08 PM 3. S ETUP AC Po wer This fixture runs on 100~240 VAC, 50/ 60 Hz. Before power ing on the unit, make sure the line voltage to which you are connecting i t is within the ra nge of accepted voltage s. Always connec t the fixture to a switched c ircuit.
3. Setup 7 4/19/2010 1:08 PM Mounting Bracket Secondary brac ket (used primarily for standing posi tion) Mounting Orientation The LEDrain™ 56 C may be mounted in any safe po sition prov ided there is adequate roo m for ventilation. Rigging Be sure that the structure can support the w eight of the fix ture.
4. Operating In structions 8 4/19/2010 1:08 PM 4. O PERATING I NSTRUCTIONS Configuring the Starting A ddress Each fixture req uires a starting ad dress from 1~51 2. A fixtur e requiring one or more channels for control begins to read the data on the channel indicated by the star ting addre ss.
4. Operating In structions 9 4/19/2010 1:08 PM Master/Slave Mode (Sound-A ctive, A uto Mode, Static Co lors) This mode allow s a single uni t to run a standalon e progra m, while 1 or more other units fo llow the same operation. This requires the fixture s to be linked w ith DMX cables.
4. Operating In structions 10 4/19/2010 1:08 PM Standalone Oper ation Automatic This fixture has a preprogr ammed color fade program. This is acces sed via the DIP switche s on the back of the fix ture, and the spee d may be increased, as well. Plea se see the chart below for further explanation.
4. Operating In structions 11 4/19/2010 1:08 PM DMX Channel Values 7- CH Mode C HANNEL V ALUE F UNCTION 1 000 255 Red Dimmer: 0%~100 % 2 000 255 Green Dimmer: 0%~100 % 3 000 255 Bl ue Dimmer: 0%~100 % 4 000 015 016 255 Color Macros ( overrides CH .
5. Appendix 12 4/19/2010 1:08 PM 5. A PPENDIX DMX Primer There are 512 chan nels in a DMX connection. Cha nnels may be assi gned in any manner. A fix ture capable of receiving DMX w ill require one or a nu mber of seque ntial chann els.
5. Appendix 13 4/19/2010 1:08 PM Data Cabling To link fix tures together yo u must obtain data cables. You can pur chase CHAU VET® certified DM X cables directly fro m a dealer/distri butor or con struct your own cable.
5. Appendix 14 4/19/2010 1:08 PM This drawing provides a general illustration of the DMX input/output panel of a lighting fixture. Universal DMX Controller Continue the link 3-Pin to 5-Pin Co nversion Ch art If you use a control ler with a 5-p in DMX output connector, y ou will need to use a 5- pin to 3-pin adapt er.
5. Appendix 15 4/19/2010 1:08 PM Setting the Sta rting A ddress This DMX mode enables the use o f a universal DM X controller device. Each fix ture require s a start add ress from 1~ 51 2. A fix ture requirin g one or more channe ls for control begins to re ad the data on the channe l indicated by the start address .
5. Appendix 16 4/19/2010 1:08 PM Returns Proced ure Returned merchandise must be sent prepaid an d in the original packin g; call tags w ill not be issued. Package must be clearly labeled w ith a Return Mer chandize Authori zation Nu mber (RMA #). Products retur ned withou t the RMA # w ill be refused .
Technical Speci fications 17 4/19/2010 1:08 PM Technical Specif ications WEIGHT & DIMEN SIONS Length .......................................................................................................................... 7.6 in ( 194 mm ) Width .
デバイスChauvet 56Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chauvet 56Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChauvet 56Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chauvet 56Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chauvet 56Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chauvet 56Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChauvet 56Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chauvet 56Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChauvet 56Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。