ChauvetメーカーSCAN LED 300の使用説明書/サービス説明書
ページ先へ移動 of 20
User Manual.
CHAUVET®, 2010, All Rights Reserved Information and specifications in this User Manual are s ubject to change without notice. CHAUVET® assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Author: Anthony Chiappone Revision: 01 Release Date: 10-08-2 010 T ABLE OF C ONTENTS 1.
1. Before You Begin 3 10/25/2010 10:23 AM 1. B EFORE Y OU B EGIN What is included • 1 x Intimidator™ Scan LED 300 • 1 x Mounting bracket kit • 1 x Power Cord • 1 x Warranty Card • 1 x User.
1. Before You Begin 4 10/25/2010 10:23 AM Safety Instructions • Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.
2. Introduction 5 10/25/2010 10:23 AM 2. I NTRODUCTION Product Dimensions.
2. Introduction 6 10/25/2010 10:23 AM Product Overview Bracket Adjustment Knob DMX In DMX Out Power Out Fuseholde r Power In Voltage Selection Switch (115/230 V AC) Safety.
3. Setup 7 10/25/2010 10:23 AM 3. S ETUP AC Power This fixture is switchable and runs on either 115 VAC, 60 Hz or 230 VAC, 50 Hz power. Before powering on the unit, make sure the line voltage to which you are connecting it matches the current setting on the voltage selection switch.
3. Setup 8 10/25/2010 10:23 AM Mounting Orientation The Intimidator™ Scan LED 300 may be mounted in any position provided there is adequate room for ventilation. Rigging Be sure that the structure can support the wei ght of the fixture. Pl ease see the “Technical Specifications” section of this m anual for a detailed weight listing.
4. Operating Instructions 9 10/25/2010 10:23 AM 4. O PERATING I NSTRUCTIONS Using the Control Panel Access control panel functions using the four butto ns located directly underneath the LED display on the included wired remote.
4. Operating Instructions 10 10/25/2010 10:23 AM Operation DMX Operation This is the operating mode which will allow for c ontrol with an external DMX controller.
4. Operating Instructions 11 10/25/2010 10:23 AM Sound-Active This fixture has a preprogramme d, sound triggere d chase. Access this via the control panel on the front of th e fixture. Adjust the microphone s ensitivity from the control panel. Please see the char t below for further explanation.
4. Operating Instructions 12 10/25/2010 10:23 AM DMX Channel Values 11-CH Mode C HANNEL V ALU E F UNCTION C HANNEL V ALUE F UNCTION 1 000 Ù 255 Pan 0°~180° 7 000 Ù 015 016 Ù 127 128 Ù 239 240 Ù.
4. Operating Instructions 13 10/25/2010 10:23 AM 7-CH Mode C HANNEL V ALU E F UNCTION C HANNEL V ALUE F UNCTION 1 000 Ù 255 Pan 0°~180° 6 000 Ù 015 016 Ù 127 128 Ù 239 240 Ù 255 Gobo Rotation S.
5. Appendix 14 10/25/2010 10:23 AM 5. A PPENDIX General Troubleshooting S YMPTOM P OSSIBLE C AUS E ( S ) P OSSIBLE A CTION ( S ) Breaker/Fuse keeps blowing • Excessive circuit load • Check total load placed on the electrical circuit.
5. Appendix 15 10/25/2010 10:23 AM DMX Primer There are 512 channels in a DMX connection. A fixt ure capable of receiving DMX will require one or a number of sequential channels. The user must assign a starting address on the fi xture that indicates the first channel reserved in the cont roller.
5. Appendix 16 10/25/2010 10:23 AM Cable Connectors Cabling must have a male XLR connector on one end and a female XLR connector on the other end. Do not allow contact be twe en the common and the fixture’s ch assis ground. Grounding the common can caus e a ground loop, and y our fixture may perform erra tically.
5. Appendix 17 10/25/2010 10:23 AM 3-Pin to 5-Pin Conversion Chart If you use a controller with a 5-pin DMX output connector, you will ne ed to use a 5-pin t o 3-pin adapter.
5. Appendix 18 10/25/2010 10:23 AM General Maintenance To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month.
T ECHNICAL S PECIFICATIONS WEIGHT & DIMENSIONS Length .............................................................................................................. 11 in (27 9 mm) Width ............................................................
C ONTACT U S World Wi de General Information CHAUVET® 5200 NW 108 th Ave Sunrise, FL 33351 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084 Technical Support CHAUVET® 5200 NW 108 th Ave Sunrise, FL 33351 voice: 954.929.1115 (Press 4) fax: 954.
デバイスChauvet SCAN LED 300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chauvet SCAN LED 300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChauvet SCAN LED 300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chauvet SCAN LED 300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chauvet SCAN LED 300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chauvet SCAN LED 300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChauvet SCAN LED 300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chauvet SCAN LED 300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChauvet SCAN LED 300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。