CHAPTER 2-1 Optical Transport Turn-Up and Test Guide 78-14964-01 2 Quick Installation Procedures This chapter describes procedures for installing essential hardware components.
2-2 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Perform this procedure to install the Cisco ONS 15540 ESP chassis in a standard 19-inch rack: Step 1 Place the L brackets on the sides of the chassis.
2-3 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Perform the following procedure to install the processor card in the Cisco ONS 15540 ESP. Step 1 Insert the processor card carefully into chassis slot 6.
2-4 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware T o install a redundant processor card, perform the next procedure.
2-5 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Installing Mux/Demux Motherboards and Mux/Demux Modules The Cisco ONS 15540 ESP chassis uses one optical mux/demux motherboard for unprotected operation or two per system for protected operation.
2-6 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Installing 4-Channel or 8-Channel Mux/Demux Modules This section describes the procedure for installing a 4-channel or 8-channel mux/demux module in the Cisco ONS 15540 ESP.
2-7 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware T ransponders are av ailable in single-mode, and multimode. Line card motherboards are available with or without splitter protection.
2-8 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Installing SM Transponder Modules or MM Transponder Modules Perform the follo wing procedure to install SM transponder modules or MM transponder modules.
2-9 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESP Hardware Step 3 Lift the latch handle on the extended range transponder .
2-10 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Connecting Mux/Demux Module and OSC Ports Perform the follo wing steps to connect the motherboard and module.
2-11 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Preparing to Install the Chassis Perform this procedure to install the Cisco ONS 15540 ESPx chassis in a standard 19-inch rack: Step 1 Place the L brackets on the sides of the chassis.
2-12 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Installing Cross Connect Drawers The process for installing the cable storage and cross connect drawers is the same.
2-13 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Installing the Vertical Cable Guides V ertical cable guides for the Cisco ONS 15540 ESPx are installed onto the rack next to the cross connect drawers.
2-14 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware T o install a redundant processor card, perform the next procedure.
2-15 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Connecting the Console Port The console port is a female, DCE (data communications equipment), DB-25 receptacle used for connection to a console terminal or modem.
2-16 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware T o install the module, follow these steps: Step 1 Remov e the dust covers from the module, and clean the optical connectors.
2-17 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Installing Line Card Motherboards and Transponder Modules Y ou can install up to eight hot-swappable line card motherboards in slots 2 to 5 and 8 to 11 of the Cisco ONS 15540 ESPx chassis.
2-18 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Step 3 Use the handles to push the line card motherboard in until it is fully seated in the backplane connector .
2-19 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Installing Extended Range Transponder Modules Perform this procedure to install extended range transponder modules.
2-20 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Cabling Mux/Demux Modules This section describes the connections between pairs of mux/demux modules and between mux/demux modules and mux/demux motherboards in the Cisco ONS 15540 ESPx.
2-21 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Cabling Directly with Cable Storage Drawers T o connect the C.
2-22 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Step 2 Pull out the cable storage drawer ( Figure 2-2 on page 2-22 ).
2-23 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Step 3 Lock the drawer in the open position by pushing the latch at the back left of the dra wer down into the locked position ( Figure 2-3 on page 2-23 ).
2-24 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware of the right of the cable storage drawer , enter the cross connect drawers through the right side, and connect to their destination connector .
2-25 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Figure 2-5 sho ws an unprotected conf iguration using four line card motherboards.
2-26 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Installing Cisco ONS 15540 ESPx Hardware Figure 2-6 sho ws the cross connect drawer on the Cisco ONS 15540 ESPx.
2-27 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures Step 14 Connect the MU breakout end of the cable to the bottom half of the desired adapter mux/demux connections on the inner side of the cross connect panel.
2-28 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures T o ground the shelf, follow these steps: Step 1 Use a wire-stripping tool to remov e approximately 0.75 inch (20 mm) of the covering from the end of the grounding wire.
2-29 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures Caution Use extreme care when remo ving or installing connectors so you do not damage the connector housing or scratch the end-face surface of the f iber .
2-30 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures Verifying the Power Up Once you hav e met the conditions in the “Powering Up the Chassis” section, po wer up the system.
2-31 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures 1/2 15540-MDXA-08C0= 74-2657-01 A1 ANX06040003 01/21/2002 1.0 1/3 MA-MDXA-08D0 30-1317-01 2 401118 06/21/2001 1.0 2/* 15540-LCMB-0100= 73-5813-05 02 CAB0525J5VB 02/15/2001 5.
2-32 Optical Transport Turn-Up and Test Guide 78-14964-01 Chapter 2 Quick Installation Procedures Common Installation Procedures.
デバイスCisco Systems ONS 15540の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cisco Systems ONS 15540をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCisco Systems ONS 15540の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cisco Systems ONS 15540の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cisco Systems ONS 15540で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cisco Systems ONS 15540を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCisco Systems ONS 15540の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cisco Systems ONS 15540に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCisco Systems ONS 15540デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。