Operators Manual Installation, Operation & Service Floor Model Direct Steam Kettles MODELS : KDL, KDL-T , KDL-SH, KDL-TSH, KDP , KDP-T SE95007 Rev . 6 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .
Shut off pow er at main fuse disconnect prior to ser vicing. Ensure kettle is at room temperature and pressure gauge is showing z ero or less prior to removing any fittings . Inspect unit daily f or proper operation. 0 Do not fill kettle abo v e recommended le v el marked on outside of k ettle.
GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of pr oduct could cause injury or damage. This unit is built to comply with applicable standards for manufacturers.
STEAM All steam plumbing to and from the kettle and steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. Check the rating plate for the maximum steam pressur e that your kettle is rated for .
STEAM REQUIREMENTS FOR KETTLES Kettle Cap. Kettle 25 psi Steam 265°F 40 psi Steam 287°F 80 psi Steam 302°F U .S. Gal. Dia. Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . Lbs./Hr . Hp./Hr . 40 26" 100 3 120 4 150 4.5 60 29.5" 150 4.5 190 5.5 230 7.
OPERA TING INSTRUCTIONS CLEVELAND STEAM COOKING EQUIPMENT IS INTENDED FOR COMMERCIAL USE ONL Y BY PR OFESSIONALL Y TRAINED PERSONNEL. General Parts Drawing ITEM # DESCRIPTION 1. Steam Inlet V alve Opens and closes the steam supply to the kettle. 2. Hand Wheel Used for tilting the kettle up or down.
OPERA TION 1. Ensure that ther e is an adequate steam supply to the kettle. 2. For optimum perfor mance on free-standing floor model tilting kettles, open drain cock to drain condensate from the kettle’ s jacket, then close drain cock before applying steam to a cold kettle.
CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature).
ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust.
F AUCET ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 3/4" Spouts 1. KE50825-2 KDL-60/80/100-T , KDP-60/80-T . . . . . . . . .1 KE50825-3 KDL-25/40-T , KDP-25/30/40-T . . . . . . . . . .1 KE50825-7 KDL-40/60/80-TSH, . . . . . . . . . . . . . .
STEAM CONTROL ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE51892 Retaining ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51888 W asher . . . . . . . . . . . . . . . . . . . .
CONTROL CONSOLE COMPONENTS - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1. F A11134 Screw , #1-24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. F A11501 Screw . . . . . . . . . . . .
CONTROL CONSOLE COMPONENTS - HAND TIL T.
ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE55057-10 Gear Box Lid (25-60 gallon) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE55057-3 Gear Box Lid (80 gallon & up) . . . . . . . . . . . . . . . . . . . . . . .
CONTROL CONSOLE COMPONENTS - POWER TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 8. SE00028 Steam Inlet Knob Assembly (Item no. 7 included) . . . . . . . . . . . . . . . . . . . . . . .1 9. KE50441 Tilt Shaft . . . . . . . . . . . . . . . . . . . . . .
HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P ART NO . DESCRIPTION QTY . Hinge Assembly 1. - 11 KE50597-1 25 - 40 Gallon, 20 Gallon Full Jacketed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50597-2 60 - 80 Gallon, 30 - 40 Gallon Full Jacketed .
1 2 3 4 5 6 7 T ANGENT DRA W-OFF V AL VE ITEM NO. P ART NO. DESCRIPTION QTY . 1. - 7. KE50973 2” DRAW-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50972-B 3” DRA W-OFF ASSEMBL Y . . . . . . . .
PRESSURE RELIEF V AL VE TESTING PROCEDURE The pressur e relief valve must be checked at least twice a year as part of the normal maintenance per formed.
TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only . PROBLEM A / Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow . Check for correct steam using chart below .
デバイスCleveland Range KDP-Tの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cleveland Range KDP-Tをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCleveland Range KDP-Tの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cleveland Range KDP-Tの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cleveland Range KDP-Tで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cleveland Range KDP-Tを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCleveland Range KDP-Tの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cleveland Range KDP-Tに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCleveland Range KDP-Tデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。