USER MANUAL uSign™ Signature Capture Module Models uSign 100 & uSign 200 80084501-001-A 04-24-2007.
uSign User Ma nual FCC WARNING STATEMENT This equipment has been tested and found to comply with the limit s for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interferenc e when the equipment is operated in a commercial environment.
uSign User Ma nual LIMITED WARRANTY ID TECH warrants to the origin al purchaser for a period of 12 months from the date of invoice that this product is in good worki ng order and free from defects in m aterial and workmanship under normal use and service.
uSign User Ma nual Table of Contents 1.0 Introduction .................................................................................................6 2.0 Features .....................................................................................
uSign User Ma nual 7.4.6 Get data 0x 00 0x01 .......................................................................15 7.4.7 Calibrate t he devic e ....................................................................... 15 7.4.8 Set offset positio n .
uSign User Ma nual 1.0 Introduction The use of electronically captured signatures has become common for Point of Service (POS) applications. Electronic signature capt ure reduces transaction time, eli.
uSign User Ma nual 3.0 Model Designations uSign 100 IDUA-01x100 * uSign 200 IDUA-01x500 * * The “x” defines the communication interfac e, 2 = RS232 and 6 = USB-CDC.
uSign User Ma nual 5.1 Communication Interfaces RS232 The uSign has a communication cable with a DB25 (100 Model) or DB-9 (200 Model) connector that fits the computer serial (RS232) COM port connection. See the Specifications, Interface Sect ion for COM port settings.
uSign User Ma nual Figure 1 New Hardware Wizard opening window Browse and select the folder where the uSignUsbCD C.inf and companion usbser.sys files are located. Click Next > to continue. Figure 2 Browse for File Copyright © 2006, International Technologie s & Systems Corp.
uSign User Ma nual There is a warning window that the INF file is not registered; Click “Continue Anyway”. Click Finish to complete the INF installation. Figure 3 Installation Warning Message 5.2 USB-CDC Setup The following steps provide a check on the USB-CDC COM port selected by the operating system.
uSign User Ma nual 6.3 Physical housin g uSi gn 200 Overall size 129mm wide (5.1 in) 146mm length (5.75 in) 40mm thick including back plate (1.57 in) Display 3.
uSign User Ma nual 10% to 95% non-condensing Copyright © 2006, International Technologie s & Systems Corp. All rights reserved. Page 12 of 18.
uSign User Ma nual 7.0 uSign commands description (Version: 0.02 Date: 2007-03-19) Note: di gits are given in little-endian format. 7.1 Command protocol: Host to device: STX LenL LenH CommandData Lrc1 Lrc2 ETX STX: 0x02. 1 byte. LenL+LenH: sizeof(C ommandData).
uSign User Ma nual 7.3 One byte commands 7.3.1 Stop Capturing Command string: C0 Response string: C0 7.3.2 Start Capturing use FBP format 1 Command string: C1 Response string: C1 7.3.3 Start Capturing use FBP format 2 Command string: C2 Response string: C2 7.
uSign User Ma nual 7.3.12 Start Capturing use FBP format 0 Command string: D6 Response string: D6 7.4 Multi-byte commands 7.4.1 Initialize device Command string: 28 10 00 00 Response string: DC 05 7.4.2 Get PW120 Version Command string: 2A 10 00 00 Response string: 01 00 7.
uSign User Ma nual 7.4.11 Stop Capturing Command string: 40 30 00 00 Response string: 7.4.12 Start Capturing use FBP format 1 Command string: 41 30 00 00 Response string: 7.
uSign User Ma nual uSign™ 100 SIGNATURE CAPTURE PAD Figure 4 Outline Drawing for uSign 100 Copyright © 2006, International Technologie s & Systems Corp.
uSign User Ma nual uSign™ 200 SIGNATURE CAPTURE PAD Figure 5 Outline Drawing for uSign 200 Copyright © 2006, International Technologie s & Systems Corp.
デバイスCompaq uSign Signature Capture Module uSign 100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Compaq uSign Signature Capture Module uSign 100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCompaq uSign Signature Capture Module uSign 100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Compaq uSign Signature Capture Module uSign 100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Compaq uSign Signature Capture Module uSign 100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Compaq uSign Signature Capture Module uSign 100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCompaq uSign Signature Capture Module uSign 100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Compaq uSign Signature Capture Module uSign 100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCompaq uSign Signature Capture Module uSign 100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。