OPERATING MANUAL 300 WATT ELECTRONIC LOAD MODULE Agilent Model 60502B FOR MODULES WITH SERIAL NUMBERS: 3118A-00101 AND ABOVE Agilent Part No. 60502-90008 Printed in U.
DECLARATION OF CONFORMITY according to ISO/IEC Guide 22 and EN 45014 Manufacturer’s Name : Agilent Technologies Manufacturer’s Address: New Jersey Division 140 Green Pond Road Rockaway, NJ 07866 U.
1 300-Watt Module About This Manual This manual provides information for the Agilent 60502B 300-Watt Electronic Load Module. It is designed as a supplement to the Agilent 6050A/6051A Multiple Input Mainframe Electronic Load Operating Manual (part number 06050- 90001).
2 Table 60502-1. Specification and Supplemental Characteristics SPECIFICATIONS DC Input Rating: Current: 0 to 60 A Voltage : 3 V to 60 V (minimum dc operation from 0 to 2 V for 0 to 60 A) Power: 300 W at 40 ° C (derated to 225 W at 55 ° C) A. OPERATING CHARACTERISTICS B.
3 Table 60502-1 Specifications and Supplemental Characteristics (continued) Transient Operation: Continuous Mode Frequency Range: 0.25 Hz to 10 kHz Frequency Resolution: 4% Frequency Accuracy: 3% Duty Cycle Range: 3% to 97% (0.
4 Table 60502-1 Specifications and Supplemental Characteristics (continued) External Analog Programming 0 to 10 V (dc or ac): Bandwidth: 10 kHz (3 db frequency) Accuracy: ± 4.
5 Table 60502-1 Specifications and Supplemental Characteristics (continued) Current Slew Rate:* Rate # 60 A Range Step 6 A Range Step Transition Time 1 1 A/ms 0.1 A/s 8.0 ms 2 2.5 A/ms 0.25 A/s 3.2 ms 3 5 A/ms 0.5 A/s 1.6 ms 4 10 A/ms 1 A/ms 800 µ s 5 25 A/ms 2.
6 Table 60502-1 Specifications and Supplemental Characteristics (continued) Source Turn-On Current Overshoot: Less than 10% of final value (in CC and CR modes when connected to power supplies with voltage rise times of greater than 500 µ s). Programmable Short Circuit: 0.
7 Table 60502-2. Programming Ranges (continued) Function Front Panel Front Panel HPSL Command Range of Values Key Display (Short Form) Transient Operation Set Frequency FREQ value "TRAN:FREQ value" 0.25 Hz to 10 kHz Set Duty Cycle (shift) DCYCLE value "TRAN:DCYC value" 3-97% (0.
8 Table 60502-4. Calibration Information Ranges and Calibration Points Variables Variables Value Power Supply Settings Current Shunt High Current Range Hi_curr_rng 60 5 V/61 A 100 A High Current Offset Hi_curr_offset 0.0282 Low Current Range Lo_curr_rng 6 5 V/10 A 15 A Low Current Offset Lo_curr_offset 0.
9 Agilent Sales and Support Office For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test and measurement sales representative.
デバイスAgilent Technologies 60502Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Agilent Technologies 60502Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAgilent Technologies 60502Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Agilent Technologies 60502Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Agilent Technologies 60502Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Agilent Technologies 60502Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAgilent Technologies 60502Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Agilent Technologies 60502Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAgilent Technologies 60502Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。