Crestron electronicメーカーDM-RMC-100の使用説明書/サービス説明書
ページ先へ移動 of 28
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Operations & Installation Guide.
This document was prepared and written by th e Technical Documentation departm ent at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and tradem arks are the property of their respective owners.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Contents DigitalMedia ™ Room Controller: DM-RMC-100 1 Introduc tion ................................................................................................................... ............
.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller DigitalMedia ™ Room Controller: DM-RMC-100 Introduction The DigitalMedia ™ (DM) Room Controller (RMC) is a digital media receiver and display controller desi gned to convert DigitalMedia to regular HDMI.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 DM-RMC-100 in a Classroom Application 2 • DigitalMedia ™ Room Controller: DM-RMC-100 Operations & Installation – DOC.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller For more information on this and ot her DM-RMC-100 applications, refer to the latest revision of the Crestron DigitalMedia ™ Design Guide (Doc. 4789), which is available from the Crestron website ( www.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Physical Description This section provides information on the connections, controls and indicators available on your DM-RMC-100. DM-RMC-100 Overall Dimensions (Front View) 1 2 3 4 5 5.15 in. (13.08 cm) 4.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller DM-RMC-100 Overall Dimensions (Rear View) 12 13 14 Connectors, Controls & Indicators # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 1 PWR LED (1) Green LED indicates operating power supplied via DMNet control network.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 3 VIDEO LED (1) Red/green dual color LED i.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 8 USB (1) USB Type A female USB 1.1 port for mouse, keyboard, game controller, or other USB HID device.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 13 LAN 3 (1) 8-wire RJ-45 female; 10BaseT/100BaseTX Ethernet switch port. 14 DMNet 5, 6 (1) 4-pin 3.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller M Port PIN # SIGNAL DESCRIPTION 1 +5V +5V Power 2 I2C_DATA HDCP & EDID Data 3 E_TX- 10/100BaseT Transmit 6 E_TX+ 10/100BaseT Transmit 4 E_RX- 10/100BaseT Receive 5 E_RX+ 10/100BaseT Receive 7 I2C_CLK HDCP & EDID Clock 8 +5V_RTN +5 Power Return 3.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Setup Network Wiring When wiring the DMNet network, consider the following: NOTE: DMNet wiring and Cresnet ® wiring are not compatible. • Use Crestron Certified Wire. • Use Crestron power supplies for Crestron equipment.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 • Metal mounting plate (supplied) • 4-Pin connector plugs (supplied) It is assumed that DigitalMedia cable (DM-CBL) has been fed through an installed two-gang electrical box, 85mm European or 1900 electrical box (not supplied) and wiring has been verified.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Mounting DM-RMC-100 into Electrical Box DM-RMC-100 METAL MOU NTING PLA TE (2019091) DRYWALL MOUNTING SCREWS (4) (2007215) Hardware Hookup Make the necessary connections as called out in the illustration that follows this paragraph.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Hardware Connections for the DM-RMC-100 (Front View) SENS: CURRENT OR MOTION SENSO R HDMI: DISPLAY HDMI USB: MOUSE, KEYBOARD O R GAME CONTROLLER RE.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Hardware Connections for the DM-RMC-100 (Back View) LAN: ETHERNET EQUIPPED DISPLAY OR OTHER DEVICE DM INPUT DMNet NOTE: Ensure the unit is properly grounded. NOTE: For optimum performance, Crestron strongly recom mends using DM-CBL DigitalMedia ™ cable, available from Cr estron.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Uploading and Upgrading Crestron recommends using the latest program ming software and that each device contains the latest firmwa re to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to establish communication.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller Firmware Firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrad es are available from the Crestron website as new features are develope d after product releases.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller DM-RMC-100 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION DM LINK LED does not illuminate. Device is not receiving DMNet signal. Verify DMNet is properly attached. PWR LED does not illuminate.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Check Network Wiring Use the Right Wire In order to ensure optimum perform ance over the full range of your installation topology, Crestron Certified Wire and only Crestron Certified Wire may be used.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller NOTE: All Crestron certified DMNet wiring must consist of two twisted pairs. One twisted pair is the +24V conductor and the GND conductor and the other twisted pair is the A conductor and the B conductor.
DigitalMedia ™ Room Controller Crestron DM-RMC-100 Return and Warranty Policies Merchandise Returns / Repair Service 1. No m erchandise may be returned for credit, exchange or service without prior authorization from CRESTR ON. To obtain warranty service for CRESTR ON products, contact an authorized CRESTRON dealer.
Crestron DM-RMC-100 DigitalMedia ™ Room Controller This page is intention ally left blank. Operations & Installation – DOC. 6743A DigitalMedia ™ Room Controller: DM-RMC-100 • 23.
Crestron Electronics, Inc. Operations & Installation Guide – DOC. 6743A 15 Volvo Drive Rockleigh, NJ 07647 (2022552) Tel: 888.CRESTRON 12.08 Fax: 201.
デバイスCrestron electronic DM-RMC-100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Crestron electronic DM-RMC-100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCrestron electronic DM-RMC-100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Crestron electronic DM-RMC-100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Crestron electronic DM-RMC-100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Crestron electronic DM-RMC-100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCrestron electronic DM-RMC-100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Crestron electronic DM-RMC-100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCrestron electronic DM-RMC-100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。