Aiphoneメーカー0311 A OIの使用説明書/サービス説明書
ページ先へ移動 of 60
6(5 9,&(0$18$/ Installation manual 0311 A OI GT SYSTEM Apar tment Inter com System.
- 2 - PRECAUTIONS W ARNING (Negligence could result in death or serious injury .) 1. The units must be installed and wired by a qualified technician. Having installation performed by an unqualified technician could result in electric shock. 2. Do not dismantle or alter the unit.
- 3 - Table of Contents 1 SYSTEM CONFIGURA TIONS Standard system configuration ................................................................................................. .......................4 Expanded system configuration diagram .........
- 4 - This system is constructed with a 2-line communication system and a 2-line video system and requires minimal work for installat ion. The system is constructed with video trunk lines consisting of a maximum of 6 trunks from the video bus control system and communication trunk lines that use a distribution point from a b us control unit.
- 5 - #6 #1 #2 #3 #4 #5 #6 #1 #2 #3 #4 #5 #6 #1 #2 #3 #4 #5 #6 #1 #2 #3 #4 #5 PS-2420, PS-2420S, PS-2420UL PS-2420DIN PS24 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S 2 B A.
- 6 - Audio signal line (1) Video signal line (1) P ower supply line (1) 4-wa y video junction unit GT -4Z 4-wa y video junction unit GT -4Z T runk line #1 Each residence Each residence Each residence.
- 7 - PS24 A I P H O NE J F -D VF JK-DA JK-DV JK-DVF PS24 Master monitor station (with recording function) GT -2C-L, GT -2C Residential monitor station GT -1C-L, GT -1C Sub master monitor station GT -.
- 8 - 2 B A C 1 7 R Q P S 0 3 E D F 4 H G I 5 K J L 6 N M O 8 U T V 9 Y X W Z 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S 2 B A C 1 7 R Q P S 0 3 E D F 4 H G I 5 K J L 6 N .
- 9 - W ire diameter W iring distance 0.65 mm (22 A WG) 0.8 mm (20 A WG) 1.0 mm (18 A WG) [1] GT -BC - DP *2 3 m (10') 5 m (16') 5 m (16') [2] Entrance station - DP *2 150 m (490').
- 10 - 2 COMPONENTS Entrance Station (Unit type) 2-1 Panel Module Speech module panel (guidance-enabled type) GT -DP-L Speech module (guidance-enabled type) GT -D A-L (connector included) Speech modul.
- 11 - Mounting parts Combination examples 4-module front frame GT -4F Mounting brack et (included with GT -4F) Screws 3-module front frame GF-3F Mounting brack et (included with GF-3F) 2-module front.
- 12 - Video bus control unit GT -VBC Expanded bus control unit GT -BCX (mounting brack et included) P ower supply PS-2420DIN Bus control unit GT -BC External signaling relay GT -R Y P ower supply PS-.
- 13 - Door station Security guar d station 2-5 2-6 Residential station GT -1A Door station GT -D Wood mounting scre ws Screws 2 B A C 1 3 E D F 5 K J L 4 H G I 6 N M O 8 U T V 7 R Q P S Y X W Z 9 0 S.
- 14 - 3 MOUNTING Mounting locations Appr opriate cable 3-1 3-2 • For video entrance stations and video door stations, the picture quality of residential station monitoring is af fected by the natur.
- 15 - Mounting positions and image view area 3-3 When using the camera module, if the rain hood is attached a portion of it will show up in the camera display .
- 16 - Entrance Station (Unit type) 3-4 1 Mak e a hole for the cable. 2 Use the joint pipe to assemble the back box. • Make sure the back box is mounted level. 1 2 Joint pipe Joint pipe Back box Options Rain hood GT -203H Surface-mount box GF-203BA Hooded surface-mount box GT -203HB 80 cm (32") connection cable GF-C 3 Assemble the module.
- 17 - GT-DA-L/GT-DA 1 0 3 ON 1 23 4 CN 2 CN 1 6 CN2 CN1 CN2 CN1 CN2 CN1 CN2 CN1 CN2 CN1 8 9 GT-DA-L/GT-DA 1 0 3 ON 1 2 34 CN 2 CN 1 10 11 GT-SW GT-AD 6 Remo ve the terminal cov er . 8 Connect the connectors between the modules with cables. Mount modules on the back boxes.
- 18 - Entrance Station (Integrated type) 3-5 GT-DMV GT-DM 3 1 2 4 Flush mount back box Special screwdri ver Unit 125 mm (4-15/16") 380 mm (15") 60 mm (2-3/8") Mounting screws ×4 1 Open the co ver and connect the wiring to the terminal block.
- 19 - Bus contr ol unit, 4-way video junction unit and po wer supply 3-6 DIN rail mounting The length of the connecting cable between the GT -BCX and GT -VBX is 40 cm. Therefore, mount them adjacently to each other . Direct mounting to wall surfaces Use the wall mounting scre ws to mount the unit to a wall surface.
- 20 - Surface wiring * When a 3-gang box is not mounted, the cable can be routed as surface wiring to the top or bottom of the unit. Cut a cable inlet on the upper part of the unit to allow passage of the wiring into the unit. If there is a large amount of wiring, strip away the jacket of the cable up to the cable inlet.
- 21 - 3 1 Mount the mounting bracket on the 1-gang box or round back box. 2 Connect the wiring to the terminal block. • T o remove the terminal block, slide the terminal block and pull it out. • Strip away the jacket of the cable and insert all wires into the slots in an orderly fashion.
- 22 - Door station 3-8 For door stations other than the GT -D, see the included instructions. 1 Mount the station unit to the chassis or mounting brack et. 2 Connect the wiring to the terminal block. GT -1M-L: • T o remove the terminal block, slide the terminal block and pull it out.
- 23 - GT-MK Security guar d station 3-9 Peel off the protection film on the display . Desk-top mounting using the GFW -S stand W all mounting 1 Mount the mounting bracket on the 1-gang box or round back box. 2 Connect the wiring to the terminal block.
- 24 - 4 WIRING Standar d system for common area 4-1 #4 #5 #1 #2 GT-MK GT-DMV/GT-DM PS24 AC AC AC/DC AC NP PT PT R1 R2 R1 R2 C CE + - R1 R2 R1 R2 C CE + - 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M.
- 25 - A1 A2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 + - A1 A2 A1 A2 A1 A2 A1 A2 IN1 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 IN2 IN3 IN4 IN5 A1 A2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 + - A1 A2 A1 A2 A1 A2 A1 A2 IN1.
- 26 - Standar d system for residence (station-to-station wiring) 4-2 GT-VBC GT-BC GT-1C-L GT-1C GT-1M-L GT-1A GT-1D GT-2C-L GT-2C GT-2C-L GT-2C GT-2C-L GT-2C GT-2H-L GT-2H #1 #2 #3 GT-2H-L GT-2H PS24.
- 27 - Standar d system for residence (homerun wiring) 4-3 OUT(2) OUT(4) B1 B2 R1 R2 B1 B2 R1 R2 IN LINE OUT B1 B2 R1 R2 B1 B2 R1 R2 OUT(1) OUT(3) B1 B2 R1 R2 B1 B2 R1 R2 SW1 A B OUT(2) OUT(4) B1 B2 R.
- 28 - Expanded system 4-4 2 3 1 7 8 4 5 9 10 6 PS24 AC GT-VBX GT-BCX R1 R2 + - A2 A1 R1 R2 + - A2 A1 R1 R2 + - A2 A1 R1 R2 + - A2 A1 R1 R2 + - R1 R2 R1 R2 R1 R2 + - R1 R2 + - A2 A1 GT-MK GT-DMV/GT-DM.
- 29 - Put each piece of wiring in a separate sheath as shown in the diagram below . PS24 + - PS-2420 PS-2420S PS-2420UL PS-2420DIN GT-4Z R1 R2 + - GT-BC GT-VBC 4 2 3 1 86 75 A1 A2 B1 B2 B1 B2 A1 A2 I.
- 30 - Option connector 4-5 GT-2C-L GT-2C GT-1C-L GT-1C DC DC RY RY SW SW GT-1M-L GT-MK GT-1A GT-1D KE C K CE RY RY SW SW K KE RY RY SW SW S1 S1E S2 S2E S3 S3E V+ V - DC DC RY RY SW SW DC DC RY RY SW SW SW SW RY RY 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S Emergency alarm Emergency alarm (JP1 is cut during use.
- 31 - External signaling rela y connection 4-6 * When the GT -R Y is connected, the separate option connecter (4-5) is re- quired. GT -R Y contact specification: A C/DC 24 V , 0.
- 32 - 5 SETTINGS (COMMON AREA) Perform the following settings at an entrance station or security guard station. Depending on the setting item, some items are set by switching DIP switches and some are set using the program mode menu.
- 33 - GT -NS-V/GT -NS GT -DMV/GT -DM SELECT LANGUAGE SELECT LANGUAGE MENU :ENTER SELECT LANGUAGE GUIDE LANGUAGE CHANGE ID CODE GT -MK ● Program Mode Setting method 5-2 Settings can be performed with the GT -NS-V/GT -NS, GT -DMV/GT -DM, and the GT -MK.
- 34 - GT -NS-V/GT -NS GT -DMV/GT -DM GT -MK SW1 1 2 3 4 1 ON SW1 1 2 3 4 1 ON 4 ON SW2 1 2 3 4 2 B A C 3 E D F 5 K J L 8 U T V 4 H G I 6 N M O 1 0 9 Y X W Z 7 R Q P S Before performing settings, it is recommended that users register an ID code so that other people cannot access the system.
- 35 - If the entrance station is a 10 key type or a GT -MK, program the resident information (names and room numbers) before performing the system settings. Up to 500 resident information entries can be registered. ● Programming with a PC • Y ou can use a PC to enter data and write in or change resident names.
- 36 - Residential station IDs are automatically assigned during link setting. Howe ver , with the GT -2C-L/GT -2C and GT -1C-L/GT -1C units only , they can be set manually using the switches on the unit.
- 37 - ON ON OFF GT -BC 1 4 3 GT -SW Beep 5 GT -NS-V/GT -NS GT -DMV/GT -DM Beep Beep 101 SMITH 101 SMITH ● Performing settings from an entrance station 1 Check that all units are mounted and wired correctly , and then turn on the power switch of the GT -BC.
- 38 - 6 Press the OFF button to finish programming. W ith the handset type module, return the handset. Repeat steps 3 to 6 to program all residential stations. 7 Press the program switch of the GT -D A-L/GT -D A to finish programming. The in use LED will go out.
- 39 - 1 Check that all units are mounted and wired correctly , and then turn on the power switch of the GT -BC. 2 Enter the program mode at the GT -MK and select "PR O- GRAMMING" from the menu. W ait until "CONNECTING..." is displayed.
- 40 - T ransfer link setting information set at an entrance station or security guard station to other entrance stations and security guard stations. ● Enter the program mode and select "TRANSFER D A T A". T ransf erring link inf ormation 5-8 Enter an entrance station number (1 to 16) for the transferred station.
- 41 - GT -D A-L/GT -D A ● Performing settings from an entrance station (Unit type) ● Performing settings from an entrance station (Integrated type), security guard station Link chec k 5-9 Press the program switch of the GT -D A-L/GT -DA for at least 5 seconds.
- 42 - ● Enter the program mode with the GT -NS-V/GT -NS, GT -DMV/GT -DM or GT -MK and select "SET TIMER". • Operation timer: If the operation panel is not operated for a certain period of time, the system returns to standby mode. The initial setting is 15 seconds.
- 43 - ● Start the program mode with the GT -NS-V/GT -NS, GT -DMV/GT -DM or GT -MK and select "SELECT LANGUA GE". The initial setting is English. Select English, French, German, Spanish, Dutch, or Italian. Select the guidance language that will be heard when a call is receiv ed, etc.
- 44 - GT -DMV/GT-DM MENU :ENTER ST ANDBY SCREEN BRIGHTNESS SORT SETTING ST ANDBY SCREEN GREETING OPERA TION PICTURE :ENTER ● GT -NS-V/GT -NS: Use 3 of SW1 to change the greeting message to an operation message. The initial setting is for a greeting message.
- 45 - Set the entrance station display to show room numbers or to display only resident names. The initial setting is for the room number to also display .
- 46 - Select either name order or room number order for searching at entrance stations and security guard stations. The initial setting is name order . ● GT -NS-V/GT -NS, GT -DMV/GT -DM, GT -MK: Enter the program mode and select "SOR T SETTING".
- 47 - Up to 500 access codes can be set for door release at an entrance station. The number of digits for access codes can be set anywhere in the range from 4 to 6. The initial setting is 4 digits. * Setting the access code number of digits GT -NS-V/GT -NS, GT -DMV/GT -DM: Enter the program mode and select "A CCESS CODE".
- 48 - GT -V A SW1 ON 1 2 3 4 WIDE ON 1 2 3 4 ZOOM ON 1 2 3 4 ZOOM 3s >> WIDE ON 1 2 3 4 WIDE 3s >> ZOOM Monitoring with the entrance station camera from a residential station can be set to be possible or not possible. The initial setting mak es this not pos- sible.
- 49 - Select "LIGHT CONTR OL" or "CCTV SWITCH" for the operation performed when the light button on a residential station is pressed. The initial set- ting is OFF ("LIGHT CONTR OL"). ● GT -V A: Switch this setting with 2 of SW1.
- 50 - Perform settings for whether calls to security guard stations and emergenc y alarms are transferred from the R Y -R Y terminal. The initial settings are for calls and alarms to be transferred. ● GT -MK: Enter the program mode and select "OPTIONAL OUTPUT".
- 51 - GT -DA-L/GT-DA GT -DA-L/GT-DA The picture can be set to display at the position set for zoom picture display when a residential station is called from an entrance station. The initial set- ting is for display at the center . Perform this setting in the pre-set mode.
- 52 - Setting using a residential station (limited to stations with a zoom/wide function) The picture can be set to display using a set zoom picture position for when a call is receiv ed from an entrance station. When switching from the wide screen to the zoom screen, the zoom screen displays starting from the pre-set position.
- 53 - 1 Loosen the base screw of the speech module and open and remo ve the front panel. 2 Remove the rubber cap and use a fine scre wdriver to push the setting switch. The in use LED will blinks. 3 While the in use LED is blinking (approximately 15 seconds), press the call button to assign it as the light b utton.
- 54 - 6 Setting (GT -2C-L/GT -2C) How to use the MENU Security guar d station settings 6-1 6-2 1 In the standby mode, press the [ ADJUST] button and [ ZOOM/WIDE] button until the w arning screen displays. Press the [ MENU] button in accordance with the warning screen.
- 55 - ALARM INPUT N/O N/C DISABLE EXTERNAL INPUT SETTING SENSOR 2 SENSOR 3 SENSOR 1 SENSOR1 SETTING UTILIT Y SE C URIT Y D ISA B LE Emergency input settings External input setting 6-3 6-4 1 After performing steps 1 in section 6-1, select "ALARM IN- PUT" in the "INST ALLA TION" screen and press the [ MENU] button.
- 56 - UTILITY-SENSOR DETECTION METHOD N/C N/O SECURITY-SENSOR DETECTION METHOD N/C N/O EXTERNAL INPUT SETTING SENSOR 2 SENSOR 3 ALARM TRANSFER SENSOR 1 SECURITY ALARM TRANSFER DISABLE NO TRANSFER FOR.
- 57 - DOCTOR CALL DISABLE ENABLE PRESS TO T ALK DISABLE ENABLE Doctor call setting Press-to-talk setting 6-5 6-6 1 After performing steps 1 in section 6-1, select "DOCTOR CALL" in the "INST ALLA TION" screen and press the [ MENU] button.
- 58 - INITIALIZE RETURNING TO DEF AUL T ? THIS OPERA TION CANNOT BE CANCELED. NO YES Initializing 6-7 All settings can be restored to their condition at the time of purchase. 1. Recorded pictures are erased and settings are reset. 2. Pre-set functions are not reset.
- 59 -.
- 60 - AIPHONE CO., L TD., NAGO Y A, JAP AN AIPHONE CORPORA TION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVR Y , FRANCE http://www .aiphone.net/ This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to P art 15 of the FCC Rules.
デバイスAiphone 0311 A OIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Aiphone 0311 A OIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAiphone 0311 A OIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Aiphone 0311 A OIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Aiphone 0311 A OIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Aiphone 0311 A OIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAiphone 0311 A OIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Aiphone 0311 A OIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAiphone 0311 A OIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。