CyberPowerメーカーCPS725SLの使用説明書/サービス説明書
ページ先へ移動 of 17
User’s Manual for: CPS725SL with USB Interface and PowerPanel™ Software ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/FAQs.
TABLE OF CON TENTS Thank you for pu rchasing a C yberPowe r System s Produc t. To enjoy all the features and benefits of this Uninte rrupt ible Po wer Syste m (U P S), plea se re ad and fol low al l instal la- tion and operation in structions co mplete ly.
CPS725SL Guaranteed Uninterrupt ible Power System 1 IMPORTANT SAFETY INSTRUCTION S (SAVE THESE INSTRUCTI ONS) This manual conta ins important safety instructions. Please read and f ollow all instructions car efully during instal lation an d operat ion of unit .
2 HOW TO D ETE RMINE TH E POW ER REQUI REMEN TS OF YOUR EQUIPM EN T 1. Make sure that the tot al Volt-Amp (VA) requirements of your computer, mon itor and peripheral equipment does not exceed 725 VA.
CPS725SL Guaranteed Uninterrupt ible Power System 3 matically shutdown to conserve battery power. Files with auto-assigned names will be saved under C: PCTem p , wher e C is the na me o f your ma in har d dr ive. File s that ha ve previo usly be en save d will b e sa ved in t hei r origi nal loc ation .
4 10. Click o n Start , point to Settings , and then click Control Panel . 11. Doubl e-cli ck on Add / Remove Programs . 12. Click th e Install Button , and follow the on-screen instructions. 13. When the installation is completed, remove the floppy disk.
CPS725SL Guaranteed Uninterrupt ible Power System 5 PowerPanel™ Log Window (Se e Figure 3 ) 1. Display Window: This area displa ys either the Event Log or the Closed Application Informa- tion . 2. Event Log: Selec t this option to view P ower- Panel™ events such as program start, program end, power failure and low battery.
6 Please note : This service must be stopped in order to run Pow erPanel ™ . To disable the service , set the Manufac- turer to None . Please note : You must be logged on as an administrator or a m ember of the administrator’s group to make these changes.
CPS725SL Guaranteed Uninterrupt ible Power System 7 7. Disconnect the battery wires fro m the battery. 8. Install the replacement battery by connect ing the red wire to the positive (+) terminal of the battery and connecting the black wire to the negative (-) terminal of the battery.
8 TROUBLE SHOOTING Problem Possible Cause Solution Full-time surg e prote ct ion o ut lets stop providing powe r to eq ui p- ment . Circuit breaker has tripped due to an overload. Turn the UPS off and unplug at least one piece of equip ment. Wait 1 0 second s, res et the c ircui t brea ker by depressing the button, and then turn t he UPS on.
CPS725SL Guaranteed Uninterrupt ible Power System 9 SPECIFICATIONS CPS725SL Capacity 725VA(400W) Input Voltage on Utility 100V to 140V Input Frequency 57 Hz to 63 Hz On-Battery Output Voltage 120Va c ± 5% Tran sf e r Ti m e 4ms Typical Max. Load for UPS Outlets (3 Outlets) 725VA(400W) Max.
10 Limi ted Warranty and Pow er Contro l Guara ntee In purchasing CPS72 5SL in the United States or Canada, the or iginal end user receives a Limited Warr anty and CyberPower's Power Control Guaran tee from Cyber Power Systems (USA), Inc. (for eas e of reading, referred to as "CyberPower").
CPS725SL Guaranteed Uninterrupt ible Power System 11 Making a Limited Warranty Claim. To make a Limited Wa rranty claim on a Product, you must do the following: 1.
12 1. Complete and ret urn the CyberPower War ranty card or provide reasonable proo f of purchase, for example, a sales receipt that establishes you as the original end-user consumer purchaser of the Product.
CPS725SL Guaranteed Uninterrupt ible Power System 13 2. As to Connected Equipment, the Power Control Guarantee covers only damage wi thin the specific terms of the Power Control Guarantee to Con nected Equipment (and on ly up to the applicable aggregate ceiling amoun t).
14 Contact Information: CyberPower's address is 5555 12th Ave East, Su ite 110, Shakopee, MN 55379 and its phone number is (9 52) 403- 9500 or (877) 297-69 37 (toll free) . CyberPower is the warrantor under this L imi ted Warranty . You may also contact Cybe rPower on the Internet at ww w.
FCC Not i c e This eq uipment has bee n teste d and foun d to com ply wit h the limi ts for a Class B Digital Devi ce , pursuant to Part 15 of the FCC Rules. These limits are d esigned to provide reasonable protection against har mful interference in residential installation.
デバイスCyberPower CPS725SLの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CyberPower CPS725SLをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCyberPower CPS725SLの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CyberPower CPS725SLの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CyberPower CPS725SLで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CyberPower CPS725SLを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCyberPower CPS725SLの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CyberPower CPS725SLに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCyberPower CPS725SLデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。