User ’ s Manual OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD CyberPower Systems Inc. www .cpsww .com K01 ‐ 0000220 ‐ 00 .
Copyright © 201 1 CyberPower Systems, Inc. IMPORT ANT SAFETY INSTRUCTIONS 1 This manual cont ains important ins tructions. Ple ase read and fol low all instructi ons carefully d uring installation and operation of the unit. Re ad this manu al thoroughly before attempting to un pack, install, or o perate the UPS.
Copyright © 201 1 CyberPower Systems, Inc. UNP ACKING Power module Input / Output terminal block cover 2 U s e r ’ s m a n u a l R e g i s t e r c a r d Rackmount left rail * 2 sets.
Copyright © 201 1 CyberPower Systems, Inc. HARDW ARE INST ALLA TION HARDW ARE INST ALLA TION These versatile UPS systems can be mo unted in a r ackmount or vertical tower orientation.
Copyright © 201 1 CyberPower Systems, Inc. HARDW ARE INST ALLA TION VERTICAL/T OWER INST ALLA TION Step 1: Rotate the Multifunctio n LCD Module Unscrew the right pan el of the Power modu le. Separate the righ t panel from the UPS. Gently lift t he LCD module out.
Copyright © 201 1 CyberPower Systems, Inc. INST ALLING YOUR UPS SYSTEM SYSTEM BLOCK DIAGRAM HARDW ARE INST ALLA TION GUIDE 1.
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS CHECK CIRCUIT BREA KER/WIRING Check branch circuit breaker rating and w iring dimensi ons with the follow ing table. UPS Capacity Branch Circuit Breake r Wiring A WG Wiring mm 2 6KV A 40A 10 A WG 5.
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS Step 1: Separate the top and botto m covers Loosen the four s crews to separate t he top and botto m covers. 7 Step 2: Fix the bottom co ver on the terminal bloc k Tighten the two screws to fix t he bottom cover on t he terminal bloc k.
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS Connect the three wires to the input t erminal block. Step 5: Output configuration Insert the output c able through t he appropriate c able gland (not included) 8 Connect the three wires to the output terminal block.
Copyright © 201 1 CyberPower Systems, Inc. BACKFEED PROTECTION BACKFEED PROTECTION OPERA TION 1. If the Bypass circ uit is shorted and th e UPS is running in Line Mode or Battery Mo de, backfeed protec tion will be ac tive and th e e xternal isolation d evice (Magnetic Contact or) will open.
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION POWER MODULE FRON T/REAR P ANEL DESCRIP TION 10 1. Power Button / Power on Indicator Master ON/OFF for the UPS.
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION BA TTER Y MODULE FRONT/RE AR P ANEL DESCRI PTION 1. On-board Replaceable Fuse Cover Replaceable fuse is accessible from t he rear panel. It m ust be done by qualifi ed personnel.
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION CONNECTION #2 : PO WER MODULE WITH MUL TIPLE BA TTERY MODULES Step 1: Connect the 1 st Battery module to the Power module using the instructions above. Step 2: Loosen the two screws to remove the battery cable retention bracket of the 1 st battery module.
Copyright © 201 1 CyberPower Systems, Inc. OPERA TION INSTRUCTIONS FOR LCD MODULE LED INDICA TORS – UPS ST A TUS LED Indicators Color UPS Status Description ON/OFF Blue UPS power is on. ON-LINE Green UPS is operating in Line Mode.
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 14 MUL TI-FUNCTION LCD MAIN MENU Press “ Enter ” button to activate “ MAIN MENU ”. MAIN MENU submenu Function Description Information Displays the UPS information. Configure Displays the UPS settings that can be config ured by the user .
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 15 LCD EVENT LOG 3 Event Logs of UPS can be recorded. 1. Press the “ ENTER ” button to activate the “ MAIN MENU ”. 2. Press the “ ▲ ” and “ ▼ ” buttons to scroll to the “ E vent Log ” option.
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 16 Configure Submenu A vailable Settings Default Setting Output V oltage = [200V] [208V] [220V] [230V] [240V] 230V* Sync Fre.
RE M Step Unsc r from t Step Conn Por t SA F CAU T CAU T LC D M OTE CON T 1: Remove the M r ew the right pa n t he UPS. Gently 2: Connect the ect the DB26 c a t ” on the front pa n F ETY.
Copyright © 201 1 CyberPower Systems, Inc. MAINTENANCE Storage T o store y our UPS for an extended period, c over it and store with the battery fully charg ed. Recharge the battery every thr ee months to ens ure battery life. Battery Replacement Please read and follow the Safet y Instructions bef ore servicing the battery .
Copyright © 201 1 CyberPower Systems, Inc. TECHNICAL SPECIFICA TIONS Model OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD Configuration Capacity (V A) 6000V A 8000V A 10000V A Capacity (W atts) .
Copyright © 201 1 CyberPower Systems, Inc. TROUBLE SHOOTING Problem Possible Cause Solution Warning O/P Overload Y our equipment requires mo re power than the UPS can provide. If the UPS is in Line Mode then it will transfer to Bypass Mode; if the UPS is in Battery Mode it will shutdown.
デバイスCyberPower OL10000Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CyberPower OL10000Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCyberPower OL10000Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CyberPower OL10000Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CyberPower OL10000Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CyberPower OL10000Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCyberPower OL10000Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CyberPower OL10000Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCyberPower OL10000Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。