TA BLE OF CONTENTS Thank you for purc has ing a CyberPower System s Product. To enj oy al l t he features and benefi t s of this Uninterruptible P ower Sys t em (UPS), please read and follow all ins t allation and operation i ns tructions complet ely.
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem DESCRIPTION INSPECT ION The box should contain t he f ollowing: (1) PowerPanel Plus ™ s oftware (floppy disk ); (1) serial int erface cable (DB -9); (1) telephone com municat ion cable; (1) user man ual; (1) warranty regis tration card; (1) UP S uni t .
HA RDWARE INSTA LLATION GUIDE 1. Your new UPS m ay be us ed imm ediately upon recei pt . However, recharging the battery for at least four hours is rec om mended to i ns ure that the battery’ s maximum charge capac i t y is achieved. Charge l os s may oc c ur during shipping and s t orage.
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem POWERPANEL PLUS™ SOFT WA RE INSTALLA TI ON GUIDE (Note: Use of the software is optional. The UPS will provide surge suppression and bat tery backup without the s oftware. You mus t use the sof t ware if you wish to have the aut om atic s hutdown feature).
POWERPANEL PLUS™ SOFT WA RE USER MANUA L OVERVIEW PowerPanel Plus ™ vers ion 1.13 or greater is des igned for use with W indows 95, W indows 98, W indows Me, W indows NT and W indows 20 00. The l at est version can be downloaded from www.c yb erp ower sys t em s.
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem 9. Load Level: This indicat or s hows the % of capac ity of the bat t ery outlets t hat is currentl y bei ng us ed. If the load level ex ceeds 90%, t he indicator will change to a red color. 10. Output Voltage: This indic at or shows the output volt age of the UPS.
POWERPA NEL PLUS™ SCH EDULE MENU 1. Special Setting: This set ting allows you to sc hedule a one-tim e s tartup/s hut down. 2. Schedule Di splay : This area displ ays the days/dat es and times of any scheduled s tartups and s hut downs. 3. Turn On: Selec t the day/dat e and t i m e that you want the c o m puter syst em to res t art .
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem As the battery discharges, the unit w ill beep more rapidly, indicating t hat the battery is nearing disc harge. Once the tes t is com plete, plug t he UPS back i n to the AC outl et and start your com puter.
TROUBLESHOOTING Problem Possible Cause Solution Full-tim e surge protect ion outlets stop providing power to equipment . Circuit break er has tripped due to an overload. Turn the UPS of f and unplug at least one pi ec e of equipment . W ait 10 sec onds , reset t he c ircuit break er by depres sing the button, and t hen turn the UPS on.
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem EXPECTED RUNT IME IN MINUTES Sampl e S ystems Load (Watts) CPS900A VR™ Model Runti me 75 96 125 64 150 49 200 35 250 26 300 19 350 15 400 12 450 8 500 4 REPLA CING T HE BA TT ERY CA UTION! Read and follow the IM PO RTA NT S AFETY I NSTRUC TIONS before servic i ng t he battery.
Limited Warranty A nd Power Control Guarantee In purchas i ng a CP S 900AVR in the Unit ed States or Canada, the original end user rec eives a Limited W arranty and CyberPower’s P ow er Control Guarantee from Cyber P ower Systems (US A), Inc . (f or ease of reading, ref erred to as “CyberPower”).
CPS900A VR Guaranteed Uninterruptible P o w er Sy stem The Power Control Guarantee is not “first dol l ar” c overage. CyberPower’s obligat i on i s reduced by any amount s that Init i al Cus tom.
LIMIT A TION: THE LIM ITED WARRA NT Y A ND THE POWER CONT ROL GUA RANTEE DO NOT COVER The Limi t ed W arrant y and the Power Control Guarantee are int ended t o exclus ive rights and rem edies and replace any ot her rights, t o the extent allowed by law.
FCC Notice This equipment has been tested and found to comply w ith the limits for a Class B Digital Device, pursuant to Part 15 of the FC C Rul e s. These limits are designed to provide reasonable protection against harmful interference in residential installation.
デバイスCyberPower Systems CPS900AVRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CyberPower Systems CPS900AVRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCyberPower Systems CPS900AVRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CyberPower Systems CPS900AVRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CyberPower Systems CPS900AVRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CyberPower Systems CPS900AVRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCyberPower Systems CPS900AVRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CyberPower Systems CPS900AVRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCyberPower Systems CPS900AVRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。