MODEL #: DSB-122L/DSB-122LH O WNER'S MANU AL SPLIT AIRCONDITIONING SYSTEM S1 DSB-122L/122LH(영 어 ) 01.8.17 5:29 PM 페이지2 0.
This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently.
CONTENTS 2 It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit. Safety Instructions ............................................................................................
This Installation section explains how and where to connect this new air conditioner. Please read make sure all acces- sories are included as shown below and read manual thoroughly.
OPTION AL A CCESSORIES 4 1 2 6 3 8 7 5 4 A CCESSORIES NO T SUPPLIED WITH THE UNIT : No. Description Part No. Qty Material Size 1 Drain Hose Extension 3103200200 1 PVC ID19.
5 LOC A TION OF CONTROLS Electrostatic Filter Removes dust particles from the air. Air Cleaning Filters Removes dust and prohibits germs. Emergency/Remote Switch Slide to select the desired position. Indicators Indicate the setting Sensor Wire (DSB-122LH Only) Remote Controller Storage Deodorizing Filter Removes bad smells from the air.
6 INDOOR UNIT ■ Remote Control Signal Receiver This place is the part to receive the signal if it receive the signal, you can hear the signal “ beep ” . ■ When the remote controller is lost or out- of-order, push the emergency button (EMERGENCY) to operate by hand.
7 MODE SLEEP ON/OFF TIMER ENTER/ CANCEL FAN SPEED TURBO/MILD Display Displays information pertaining to unit. TURBO/MILD Press to be colder the unit. TIMER ENTER/CANCEL Button Press to enter a timer setting or to cancel timer setting TIMER ON/OFF Button Press to set the unit of or on time.
8 DSB-122LH MODE SLEEP ON/OFF TIMER ENTER/ CANCEL FAN SPEED TURBO/MILD Display Displays information pertaining to unit. TURBO/MILD Press to be colder the unit. TIMER ENTER/CANCEL Button Press to enter a timer setting or to cancel timer setting TIMER ON/OFF Button Press to set the unit of or on time.
9 OPERA TION 1. Insert the at- tached AC plug into a pronged 220V AC outlet. AC Outlet and Plug NO TES: • Never connect the AC line cord plug to other than the specified voltage (220V). • Use the attached power cord only. • The new air conditioner system should be on it ’ s own 220V circuit.
10 CELSIUS T O F AHRENHEIT CONVERSION CHART CELSIUS FAHRENHEIT 18 64.4 19 66.2 20 68 21 69.8 22 71.6 23 73.4 24 75.2 25 77 CELSIUS FAHRENHEIT 26 78.8 27 80.6 28 82.4 29 84.2 30 86 31 87.8 32 89.6 NO TES: • When operating the remote controller, make sure there are no obstructions between the remote controller and the re - mote sensor.
11 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ ON ” will light in the remote display. 2. Make sure the AUTO indicator appears in the remote display. Using the TEMP. ▼ or ▲ buttons, set the desired temperature.
12 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ ON ” will light in the remote display. 2. Press the MODE button until the Fan indicator appears in the display. No allowance setting temperature 3.
13 FAN SPEEDS “ AUTO ” The fan will automatically select the fan speed. “” The fan will operate on low speed. “” The fan will operate on medium speed. “” The fan will operate on high speed. “ NATURAL ” The fan will randomly cycle through the speeds simulating a cool breeze.
14 2. While the unit is off, press the TIMER ON button; the display will light waiting input for the timer, but the actual unit will not turn on. 3. Repeatedly press the TIMER ON button until the de - sired hour that you want the unit to turn on appears on the display.
15 1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ ON ” will light in the remote display. 2. Press the MODE button to select the desired mode. Then, set the desired temperature using the TEMP.
16 CHANGING/CLEANING THE AIR FIL TERS To change or clean the two black air filters, follow the procedures below: 1 . Open the indoor unit ’ s cover and remove both black air filters by bending them slightly backward and the lifting out. 2 . Remove the two small filters (Deodorizing and Electrostatic) from the indoor unit.
C ARE AND MAINTEN ANCE 17 Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth. • NEVER USE Solvents, harsh chemicals or hot water to clean the unit. • Some metal edges on the unit are sharp. Be careful when cleaning or handling.
TROUBLESHOO TING GUIDE 18 Before requesting service, please refer to the chart below for possible solutions: SYMPT OMS POSSIBLE CA USE POSSIBLE SOLUTIONS No power . Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet.
19 SPECIFIC A TIONS MODEL DSB-122L DSB-122LH Function Cooling Cooling / Heating (Heat pump) Power Supply AC 220-240V, 50Hz Cooling Capacity (Heating Mode) 3,024 Kcal/h 3,150 Kcal/h (3,402 Kcal/h) Operating Current (Heating Mode) 5.
デバイスDaewoo DSB-122LHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Daewoo DSB-122LHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDaewoo DSB-122LHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Daewoo DSB-122LHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Daewoo DSB-122LHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Daewoo DSB-122LHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDaewoo DSB-122LHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Daewoo DSB-122LHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDaewoo DSB-122LHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。