CBX800 INSTALLATION MANUAL Figure A Indi c ator LE D s 1 C ov er S c rew s (4) 2 C ompr es si on Connec t or s (5) 4 25- pi n D evi ce C onne ctor 5 Hos t Interfac e Module P anel 3 NOTE For a complete Gateway configur ation using t he Genius ™ configuration program, refer to the CBX800 Help On-Lin e available on t he CD.
CBX800 INSTALLATION MANUAL 2 Figure B P ow e r s w i t ch (O N /O F F) 1 2 S ource C hass i s G rounding Selec tor 3 S o ur ce S h iel d Sel e cto r 5 4 Po w e r So u r c e Se le c t o r Mounti ng H o.
CBX800 INSTALLATION MANUAL 3 UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentatio n updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni a ggiornate di driver e doc umentazi one di questo prodotto.
CBX800 INSTALLATION MANUAL 4 DESCRIPTION The CBX800 is a Gateway connection bo x which can be used as an ac cessory to facilitate system connections for installation and device replaceme nt of se veral Datalogic family reading devices.
CBX800 INSTALLATION MANUAL 5 ACCESSORIES The following accessories are avail able on request for the CBX800: Name Description Part Number BM200/210 Ethernet TCP/IP Module STD/IP65 93AC C1851, 93ACC185.
CBX800 INSTALLATION MANUAL 6 ACCESS TO INTERNAL PARTS To make installation and replac ement easier, the CBX800 is made up of three parts: 1) the body of the device co ntaining all el ectronic componen.
CBX800 INSTALLATION MANUAL 7 MECHANICAL INSTALLATION CBX800 can be mounted to various wooden or plastic su rfaces using two self-threa ding screws (3.9 x 45 mm) and washers. Mounting to other surfaces such as concrete walls or metallic panels requires appropriate user-suppl ied parts (screws, screw anchors, nuts, etc).
CBX800 INSTALLATION MANUAL 8 NOTE Vdc is electrically connected to +V, just as GND is electrically connected to -V. T his is useful for supplying external trigger, inp uts and outputs from the CBX800 power source, how ever +V and -V signals should not be used as power supply inp uts to the CBX800.
CBX800 INSTALLATION MANUAL 9 PINOUT Pinouts Group Name Function Vdc Power Suppl y Input Volta ge + GN D Power Suppl y Input Voltage - Input Power Eart h Protection Earth Ground +V Power Source – Ex .
CBX800 INSTALLATION MANUAL 10 The input power signals Vdc , GND and Earth as well as the network signals REF , ID+ , ID- and Shield ; and RTX+ , RTX- and SGND are repe ated to facilitate system cabling. In this way the power and net work busses can enter and exit the CBX800 from different spri ng clamps but be physically connected tog ether.
CBX800 INSTALLATION MANUAL 11 SOURCE CHASSIS GROUNDI NG JUMPER SETTINGS The reading device chassis gr ounding method can be selected b y positioning a jumper (see Figure 8 ). In this way the reading device chassis c an be connected to earth gr ound (only if pin Earth is connected to a good earth ground).
CBX800 INSTALLATION MANUAL 12 RS485 HD OFF ON Figure 11 – RS485 HD Terminati on Resistance Switch The RS485 HD termination r esistance switch enables or di s ables the insertion of the bus termination resistor for RS485 Half Duplex Multidrop applicati ons.
CBX800 INSTALLATION MANUAL 13 The Net Type selector switch allows setting the Gateway type: Serial (Non e), Fieldbus, ID-NET™ network: all non net work applications (Typology Role = Other) must be set to None (0) . ID-NET ™ Slaves must be set to Slave Multidata (9) , (same ID-NET™ network Topology Role as the ID -NET™ Master).
CBX800 INSTALLATION MANUAL 14 ELECTRICAL CONNECTIONS POWER SUPPLY CBX0 0 can accept power from the conn ected reading devi ce through the 25-pin connector, or thro ugh t he dedicated spring clamp connector (see sectio n Power Source Jumper Setting s ).
CBX800 INSTALLATION MANUAL 15 Host RS232 Interface The RS232 interface can be used for connections to the host computer allowing transmission of code data.
CBX800 INSTALLATION MANUAL 16 Host RS485 Full-Duplex Interface The RS485 full -duplex (5 wires + shie ld) interface is used for no n-polled communication p rotocols in point-to-point connections over longer dista nces (max 1200 m / 3940 ft) than those acceptable for RS 232 communications or in electrically noisy enviro nments.
CBX800 INSTALLATION MANUAL 17 Host RS485 Half-Duplex Interface The RS485 half-dupl ex (3 wires + shield) interface is used for polled communic ation protocols.
CBX800 INSTALLATION MANUAL 18 AUXILIARY INTERFACE All CBX800s have an RS 232 auxiliary interface availa bl e on the 9-pin connector bel ow, which can be linked to another host computer or an external s ystem. This inte rface is mainly used for CBX8 00 configuration through Genius™, the multilanguage software tool.
CBX800 INSTALLATION MANUAL 19 DATA SOURCE INTERFACE The Data Source port can b e used for configuration and data monitoring purposes. It allows full RS232/RS485 connectivity and is software selectable.
CBX800 INSTALLATION MANUAL 20 NOTE For applications that do not u se RX485 signals, do not lea ve these lines floating but connec t them to SGND as shown below .
CBX800 INSTALLATION MANUAL 21 INPUTS The two optocoup led polarity insensitiv e inputs, Input 1 (Exter nal Trigger Input) and Input 2, a generic input, available on the CB X800 spring clamp terminal blocks, are managed by the read er connected to the 25-pin connector.
CBX800 INSTALLATION MANUAL 22 EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER Pulled down to Exte rnal Input Device Refere nce Input Signal PNP Photocell Figure 29 - PNP External Trigger Using.
CBX800 INSTALLATION MANUAL 23 Power to Input Input Device Signal Input Devi ce Reference Input Device NPN Input 2 Using CBX800 Pow er INPUT 2 CONNECTIONS USING EXTERNAL POWER Pulled down to Exter nal .
CBX800 INSTALLATION MANUAL 24 OUTPUT CONNECTIONS USING CBX800 POWER CAUTION Power is available directly to the Output Devi ce, inde pendently from the Power Supply Switch inside the CBX800.
CBX800 INSTALLATION MANUAL 25 OTHER I/O Two further input signals and one output signal, are av ail able on the CBX800 for readers that support them. These further input/output opt ions are: two o.
CBX800 INSTALLATION MANUAL 26 INDICATOR LEDS green yell ow green yell ow green blue/red yell ow green yell ow green Figure 37 – Indicator LEDs There are ten Indicator LEDs which signal power, communication, and I/O activity and are visible from the CBX800 outside cover.
CBX800 INSTALLATION MANUAL 27 TYPICAL LAYOUTS The following figure shows the general s ystem layout. Figure 38 – General S ystem Layout The general system layout a llows the CBX800 Gateway to connect any serial dev ice (Hand-Held Reader, 6K, 8KA Scanner, Matrix-2000, et c.
CBX800 INSTALLATION MANUAL 28 Fieldbus Gateway Layout CBX800 Parameters Fieldbus Gateway (ex: Profibus interface board = BM3x0 ) Note Net Type Rotary Switch 2 Address Rota ry Switches X100 = 0, 1 X10 = 0.
CBX800 INSTALLATION MANUAL 29 Ethernet TCP/IP Gateway Layout CBX800 Parameters Ethernet TCP/IP Gateway ( interface board = BM2x0 ) Note Net Type Rotary Switch 7 Topology Role Other System Layout / Mai.
CBX800 INSTALLATION MANUAL 30 ID-NET™ Gateway Layout CBX800 Parameters ID-Net Gateway Note Net Type Rotary Switch 9 Address Rota ry Switches X100 = 0.
CBX800 INSTALLATION MANUAL 31 MUX32 Gateway Layout CBX800 Parameters MUX32 Gateway Note Net Type Rotary Switch 0 Topology Role Other System Layout / Main Port Type Serial System Layout / Main Port Ser.
CBX800 INSTALLATION MANUAL 32 TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 10 to 30 Vdc* Consumption 0.8 - 0.5 A Limited Current Consumption CBX + reading device cons umption (see related manual) 2.5 A COMMUNICATION INTERFACES Host Interface RS232/RS485 up to 115.
CBX800 INSTALLATION MANUAL 33 COMPLIANCE POWER SUPPLY This product is inte nded to be installe d by Qualified Pe rsonnel only. This device i s intended to be supplied by a UL Listed NEC Class 2 pow er source.
DECLARATION OF CONFORMITY 09 Datalogic A utomation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät decl.
デバイスDatalogic CBX800の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Datalogic CBX800をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDatalogic CBX800の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Datalogic CBX800の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Datalogic CBX800で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Datalogic CBX800を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDatalogic CBX800の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Datalogic CBX800に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDatalogic CBX800デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。