DatalogicメーカーFalcon 5500の使用説明書/サービス説明書
ページ先へ移動 of 36
QRG Addendum Falcon ® 5500 RFID Mobile Hybrid Computer.
PSC Inc 959 T err y Street Eugene, Oregon 97402 T elephone: (541) 683-5700 F ax: (541) 345-7140 An Unpublished W ork - All r ights reser v ed. No par t of the contents of this documentation or the procedures described therein may be reproduced or trans mitted in any f or m or by any means without prior written per mission of PSC Inc.
Addendum i Table of Contents Overview ................................................................... ................................................... 1 Introduction ........................................................................ .....
Table of Contents ii Falcon ® 5500 RFI D Mobile Hybrid Computer NOTES.
Addendum 1 Falcon ® 5500 RFID Mobile Hybrid Computer Overview This document covers the following topics: Getting Start ed • Enabling RFID on page 2 • Reading RFID T ags on page 3 Configuration Se.
Getting Started 2 Falco n ® 5500 RFID Mobile Hybrid Computer Introduction The F alcon 5500 is a F alcon 4420 Windo ws ® CE Color M obil e Computer mounted with a special RFID unit.
Getting Started Addendum 3 4. In the Pistol T rigger column, select RFID . 5. T ap OK. F or information on other RFID configuration options, see Configuration Set- tings on page 8 . Reading RFID Tags For tag read de mo purposes: Once you have enabled the F alcon to read RFID tags, complete the following steps: 1.
Getting Started 4 Falco n ® 5500 RFID Mobile Hybrid Computer 5. The RFID tag data is enter ed into the application. 6. When the read is finished, the front LED turns off and a final beep is heard, indicating that the operation is complete. The RFID Antenna (in the RFID unit) should be positioned to face the tag location.
RFID Electrical Considerations Addendum 5 RFID Electrical Considerations Operating time U nder normal operating conditions, the RF ID batter y will last longer than the F alcon batter y . Extended continuous oper ation may result in the RFID batter y discharging before the F alcon batter y .
RFID Electrical Considerations 6 Falco n ® 5500 RFID Mobile Hybrid Computer LEDs/Indicato rs RFID Battery Charge LEDs These indicators are visible on the back of the RFID pod. The re d LED is on when the unit is in a dock and the RFID batter y is charging.
RFID Electrical Considerations Addendum 7 Figure 3. Falcon 5 500 Dock Falcon 5500 Dock Use only the correct battery c hargers and doc ks with the Falcon 5500 RFID . The technology used f or this model is incomp atible with other PSC Falcon chargers and docks, inc luding the Falcon 4410/4420 color and monochr ome models.
Configuration Settings 8 Falco n ® 5500 RFID Mobile Hybrid Computer Configuration Settings See Con figuration Examples on page 12 for samples of optimized settings for different usages. R efer to the F alcon 4400 S eries PRG for informat ion about setting other configuration items.
Configuration Settings Addendum 9 RFID Settings 1. Go to Star t > Settings > Control Pa ne l . Double-tap the Decoding icon. 2. Select Configure > RFID . 3. Choose one of the available options. Report Settings In the RFID Decoding P roperties, do the following to view or modify R epor t Set- tings: 1.
Configuration Settings 10 Falco n ® 5500 RFID Mobile Hybrid Computer Power 1. U nder Decoding Properties , go to Configure > RFID > Po wer 2. Enable/disable Gr owing Po wer by selecting the checkbox. When dis- abled, a constant level of RF po wer is output when reading tags.
Configuration Settings Addendum 11 • New T ag Timeout: The amount of time to wait between tags before painting will automatically stop. This is the maximum amount of time spent waiting for new tags after a tag has been read.
Configuration Settings 12 Falco n ® 5500 RFID Mobile Hybrid Computer Configuration Examples The follow ing examples illustrate ways to optimize RFID settings for specific situations. Reading tagged items fr om an entire shelf 1. P ress the trigger and mov e across the items on the shelf.
Configuration Settings Addendum 13 Class 1 Gen 2 Q value Q value sets the number of re spons e slots available for the tags being inventoried (number of slots = 2Q). I t is actively managed during an inventor y round, but starting wi th an appropriate Q decreases the time necessary to perform an inventory .
About RFID Tags 14 Falco n ® 5500 RFID Mobile Hybrid Computer About RFID Tags RFID Antenna When attempting to utilize the RFID re ad functionality of the F alcon 5500 RFID unit it is important to note that the antenn a is linearly polarized.
About RFID Tags Addendum 15 Tag Orientation Factors Affecting Performance • W ater or water-based products will inhibit (absorb) the signal. • M etal surfaces near the tags may affect per formance. • Misuse of tags (i.e. bending the tag antenna) could cause the tags to become dysfunctional.
Configuration Parameters 16 Falco n ® 5500 RFID Mobile Hybrid Computer Configuration Parameters The follow ing table lists the configurati on parameters which have been added to support RFID.
Configuration Parameters Addendum 17 T ag Read Beep To n e Adjusts the pitc h of the tag read bee p frequency . 0D20 V alue 00 - 08 (00 = Low est; 07 = Highest; 08 = User Def .) 00 00 00 T ag Read Beep Dura tion Deter mines th e duration of a tag read beep .
Configuration Parameters 18 Falco n ® 5500 RFID Mobile Hybrid Computer To t a l Read Timeout Sets the dur ation of the read operation be f ore it stops.
RFID Programming Labels Addendum 19 RFID Programming Labels CLASS 0 EN ABLE O n O f f CLASS 1 EN ABLE O n O f f CLASS 1 GENERAT ION 2 ENABLE O n O f f TAG READ BEEP ENABLE O n O f f READ POWER MODE G .
RFID Programming Labels 20 Falco n ® 5500 RFID Mobile Hybrid Computer TAG READ BEEP TONE 0 0 0 4 0 1 0 5 0 2 0 6 0 3 0 7 TAG READ BEEP DURATION 0 0 0 2 0 1 0 3 */ / 0 D 2 0 0 0 F F 3 E * */ / 0 D 2 0.
RFID Programming Labels Addendum 21 MINIMUM READ POWER 1 3 % 6 3 % 2 5 % 7 5 % 3 8 % 8 8 % 5 0 % 1 0 0 % MAXIMUM READ POWER 1 3 % 6 3 % 2 5 % 7 5 % 3 8 % 8 8 % 5 0 % 1 0 0 % */ / 0 D 2 9 0 1 F F 3 E *.
RFID Programming Labels 22 Falco n ® 5500 RFID Mobile Hybrid Computer CLASS 1 GENERATI ON 2 Q 0 0 0 9 0 3 1 2 0 6 1 5 * / / 0 D 3000 F F3 E * * / / 0 D 3009F F3 E * * / / 0 D 3003 F F3 E * * / / 0 D .
RFID Programming Labels Addendum 23 TOTAL READ TIMEOUT Infinite 10 seconds 25 seconds 50 seconds 70 seconds 85 seconds 99 seconds * / / 0 D 2 C 0000F F3 E * * / / 0 D 2 C 1000F F3 E * * / / 0 D 2 C 25.
RFID Programming Labels 24 Falco n ® 5500 RFID Mobile Hybrid Computer NEW TAG READ TIME OUT Infinite 1000 2500 5000 7000 8500 9999 * / / 0 D 2 D 0000F F3 E * * / / 0 D 2 D 1000F F3 E * * / / 0 D 2 D .
RFID Programming Labels Addendum 25 MINIMUM TAG READ COUNT Inifinite 1 50 100 150 200 250 * / / 0 D 2 E 0000F F 3 E * * / / 0 D 2 E 0001F F 3 E * * / / 0 D 2 E 0050F F 3 E * * / / 0 D 2 E 0100F F 3 E .
RFID Programming Labels 26 Falco n ® 5500 RFID Mobile Hybrid Computer READ REPORT FREQUENCY Inifinite 01 50 100 150 200 250 * / / 0 D 2 F0000 F F3 E * * / / 0 D 2 F0001 F F 3 E * * / / 0 D 2 F0050 F .
Safety Information Addendum 27 Safety Information FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interfer ence received, including interference that may caus e undesired operation.
Safety Information 28 Falco n ® 5500 RFID Mobile Hybrid Computer NOTES.
Safety Information Addendum 29 NOTES.
Safety Information 30 Falco n ® 5500 RFID Mobile Hybrid Computer NOTES.
.
Asia P acific PSC Hong K ong Hong K ong T elephone: [852]-2-584-6210 F ax: [852]-2-521-0291 A ustralia PSC Asia P acific Pty Ltd. Nor th Ryde, A ustralia T elephone: [61] 0 (2) 9878 8999 F ax: [61] 0 (2) 9878 8688 France PSC S.A.R.L. LES ULIS Cedex, F rance T elephone: [33].
デバイスDatalogic Falcon 5500の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Datalogic Falcon 5500をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDatalogic Falcon 5500の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Datalogic Falcon 5500の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Datalogic Falcon 5500で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Datalogic Falcon 5500を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDatalogic Falcon 5500の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Datalogic Falcon 5500に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDatalogic Falcon 5500デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。