DatalogicメーカーGryphon GM4130の使用説明書/サービス説明書
ページ先へ移動 of 364
Gr yphon™ F amily General Purpose Handheld Linear I mager or Laser Barc ode Readers Gr yphon I GD4100/GM4100 Gr yphon B T4100/ L GD4300 P roduc t Refe renc e Guide.
Datalogic Scanning, Inc. 959 T erry Street Eugene, Oregon 974 02 USA T elephone: (541) 683-57 00 F ax: (541) 345-7140 An Unpublished Work - All rights reser ved.
Prod u c t Re fe re nce G ui d e 1 T a ble of C ont ents INTRODUCTION ........... ........................................................................................................ ............................ ................................. 9 About t his Manual .
Contents 2 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 ACK Character ................................................................................ ................................. ............................. ....................................
Contents Prod u c t Re fe re nce G ui d e 3 Flash Off Time .............................. ................................................... ............................... .................... ........................................................
Contents 4 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Code 32 Feature Setting Exceptions ............................................................................... ............. ................................................ .................
Contents Prod u c t Re fe re nce G ui d e 5 Industrial 2 of 5 Check Charact er Calculation .......................................... ....................................... ...................... ............................................. 184 Industrial 2 of 5 Check Charact er Transmission .
Contents 6 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 GS1 DataBar™ Expanded Length Control .................. ............................................................. ........... ........................................ ......................
Contents Prod u c t Re fe re nce G ui d e 7 CONFIG URATIO N UPDATES ..... ........................................................................................ ............ ............................................. 263 Automatic Configuration Update .
Contents 8 Gryphon™ I GD4100/GM4100/GBT 4100/L GD4300 Display Settings ......................................... ..................................................................... ................... ..............................................
Pr oduc t Referenc e Guide 9 Chapter 1 Intr oduc tion About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming , maintenance and specifications.
Introduction 10 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Manual C on ven tions The following conventions are used in this document: The symbols listed below are used in this manual to n o t i f y.
About the Reader P roduc t Refere nce Guide 11 About the Reader Typically, units are factory-programmed for th e most common terminal and communications settings. If you need to modify any progra mmable settings, custom configuration can be accomplished by scanning the programming barcodes within this guide.
Introduction 12 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Th e BC40xx™ R adio Base Base LEDs LEDs on the Gryphon I Base provide informat ion about the Base’s status, as shown in Fi g u re 1 .
BC40XX UV Counterfeit Detection P roduc t Refere nce Guide 13 BC40XX UV C ounter f eit Detection The BC40XX Radio Base is available with a UV Counterfeit Money Detector, typically used to verify the authenticity of bank notes.
Introduction 14 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 3. The LEDs are set to switch off automatically after about 2 minutes. T o keep the UV LEDs in always-on mode, quickly press the Base button a second time within 10 seconds of the first press.
Battery Safet y P roduc t Refere nce Guide 15 Batt er y Safety To reinstall, charge and/or perform any other ac tion on the b attery, follow the inst ructions in this manual. Before installing the Ba ttery , read “Battery Safety” on this and the follo wing pages.
Introduction 16 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not.
Pr oduct Referenc e Guide 17 Chapter 2 Set u p Unpacking Check carefully t o ensure the reader and any a ccessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 10 .
Setup 18 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Installing the Inter face Cable For Corded versions, c onnect the reader cable by inserting th e cable into the handle as shown in Figure 3 . To remove it, insert a paper clip into the release aperture, then unplug the cable.
Installing the Interface Cable Product Reference Guide 19 Ke yboard W edge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. C onnect the female to the male end from the keyboard and the remaining en d at the keyboard port at the terminal/PC.
Setup 20 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 F igure 7. Other Inter face Connections RF Models The power supply connects directly to the base (not on the cable's jack) for all configurations. For all interfaces (except RS-2 32) a power supply is recommend ed but not necessary, because the base can be powered from the Host.
Configuring the Base St ation Product Reference Guide 21 Changing the Base Station Posit io n The base station is configured by installing one of two sets of mechanical parts that come with the cordless kit.
Setup 22 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 3. The stand can now be repositioned in ei ther horizontal or standing position. C onnec ting the Base Station Figure 8 shows how to connect the Base Station t o a terminal, PC or other host device.
Configuring the Base St ation Product Reference Guide 23 Securing the DC Po wer C ord ( Optional) The DC power cord for the adapter can be secured to the bottom of the base in order to maximize the mechanical retention of the cable itself.
Setup 24 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 F igure 11. Connecting to the Host Pow e r C o n n e c t i o n : Plug the AC Adapter in to an approved AC wall socket with the cable facing downwards (as shown in Figure 8 ) to preven t undue strain on the socket.
Configuring the Base St ation Product Reference Guide 25 BT M o d e l s on l y Remember: The mandat ory condit ion for establishing a new linking between a BT handheld and a BT base is that the handheld is unlinked and they share the same security configuration.
Setup 26 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 GR YPHON™ I S ystem and Netw ork Lay outs Stand Alone La y outs Fi g u re 1 3 . Single Reader Layout Fi g u re 1 4 . Multiple Reader Lay out In stand alone systems, each cradle is connected to a single Host.
GRYPHON™ I Sy stem and Netwo rk Layouts Product Reference Guide 27 Fi g u re 1 5 . Multiple Stand Alone Layouts Many stand alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses.
Setup 28 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Inte r fac e Selec tion Upon completing the physical connection between the reader and its host, proceed to Table 1 starting on pag e 29 to sele ct the interface t ype the reader is con nected to (for exampl e: RS-232, Keyboard Wedge, USB, etc.
Interface Selection Product Reference Guide 29 Table 1. Available Interfaces RS-232 FEA TURES RS-232 standard inter face Selec t RS232-STD Set RS-232 Int erfac e Fe a t u r e s starting on page 41 Sel.
Setup 30 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 KEY BOARD FEA TURES A T , PS/2 25-286, 30-28 6, 50, 50Z, 60, 70, 80 , 90 & 95 w/Standar d Key Enc oding Select KBD -A T Set KEY BOARD WEDGE I.
Interface Selection Product Reference Guide 31 KEYBO AR D — cont. FEA TURES Ke yboard W edge for IBM T erminals 31xx, 32xx, 34xx, 37xx mak e only key - board Select KBD-IBM-M Set KEY BOARD WEDGE Int.
Setup 32 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 C ustomizing C onfiguration Settings C onfigure Interface Settings If after scanning the interface barcode from the pr evious table, your install.
Customizing Conf ig uration Settings Product Reference Guide 33 Resetting the Pr oduc t C onfigura tion to Defaults Restore C ustom Defaults If you aren’t sure what programming options are in your i.
Setup 34 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Replacing the Battery To change the battery of your reader, complete the following instructions. 1. Wit h a s cre wdr iver , uns cre w th e ba tt er y c over sc rew . 2. U nscrew and remo ve the thr ee screws securing the battery holder , and unplug the white connector .
Customizing Conf ig uration Settings Product Reference Guide 35 4. Remo ve the old batter y from its place (if present), and insert the new batter y in the same position. 5. Replace the battery holder and three screws, plug in the connector , and return the contacts circuit to its pr evious location.
Setup 36 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 NO TES.
Pr oduct R efer ence Guide 37 Chapter 3 C onfigur ation U sing Barc odes This and following sections provide programmi ng barcodes to configure your reader by changing the default settings. For details about additional methods of programming, see Configur ation Methods on page 16 .
Configuration Using Barcodes 38 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Reading C onfigura tion Barcodes To program features: 1. Scan the ENTER/EXIT PR OGRAMMING barcode, available at the top of each pro - gramming page, when applicable. 2. Scan the barcode to set the desired programming feature.
ENTER/EXIT PROGRAMMING MODE Host Commands — Obey/Ignore Product Reference Guide 39 GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands.
Configuration Using Barcodes ENTER/EXIT PROGRAMMING MODE 40 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 NO TES.
Pr oduct R efer ence Guide 41 RS-232 ONLY INTERFACE Use the programming barcodes in this section if m odifications to the standard RS-232 interface settings are necessary to meet your system’s requirements.
RS-232 ONLY Interface ENTER/EXIT PROGRAMMING MODE 42 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Baud Rate See page 285 for information on this feature.
ENTER/EXIT PROGRAMMING MODE Data Bits Product Reference Guide 43 Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCI I protocol for sending and receiving data. Stop Bits Set the number of stop bits to match host device requirements.
RS-232 ONLY Interface ENTER/EXIT PROGRAMMING MODE 44 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Parity This feature specifies parity required for send ing and receiving data. Select the parity type according to host device requirements. See page 285 for more information.
ENTER/EXIT PROGRAMMING MODE Handshaking Control Product Reference Guide 45 Handshaking Control See page 285 for more information about this feature. Handshaking Control = RTS Handshaking Control = RTS.
Pr oduct R efer ence Guide 46 RS-232/USB-COM INTERFACES The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
ENTER/EXIT PROGRAMMING MO DE Intercharacter Delay Product Reference Guide 47 Intercharacter Delay This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set with in a range of zero (0) to 990 milliseconds in 10ms increments.
RS-232/USB-Com Interfaces ENTER/EXIT PROGRAMMING MODE 48 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Beep On Not on File This option enables/disables the action of th e reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
ENTER/EXIT PROGRAMMIN G MODE ACK NAK Options Product Reference Guide 49 ACK NAK Options This enables/disables the ability of the read er to support the RS-2 32 ACK/NAK protocol.
RS-232/USB-Com Interfaces ENTER/EXIT PROGRAMMING MODE 50 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
ENTER/EXIT PROGRAMMING MO DE ACK NAK Timeout Value Product Reference Guide 51 ACK NAK Timeout Value This option specifies the amount of time the re ader waits for an ACK character from the host following label transmission. The selectable time out range is 200 milliseconds to 15,000ms ( 15 seconds) in 200ms increments.
RS-232/USB-Com Interfaces ENTER/EXIT PROGRAMMING MODE 52 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 ACK NAK Error Handling This feature specifies the method the reader uses to handle receiv e errors detected while waiting for an ACK character from the host.
ENTER/EXIT PROGRAMMING MODE Disable Character Product Reference Guide 53 Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected . See page 291 for more information on setting this feature.
RS-232/USB-Com Interfaces ENTER/EXIT PROGRAMMING MODE 54 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 NO TES.
Pr oduct R efer ence Guide 55 KEYBOARD INTERFACE Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Referen ce Appendix B, Standard De faults for a listing of standard factory settings.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 56 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Country Mode This feature specifies the country/la nguage supported by the ke yboard.
ENTER/EXIT PROGRAMM ING MODE Country Mode Product Reference Guide 57 Country Mode — continued Countr y Mod e = Denm ark Supports only the interfaces li sted in the C ountry Mode fea - ture description. Cou ntr y M od e = France Cou ntr y M od e = Ge rm any Suppor ts only the inter faces listed in the Coun tr y Mode featur e des cription.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 58 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Country Mode — continued Countr y Mod e = Poland Suppor ts only the inter faces listed in the Country Mode fea - ture description. Suppor ts only the inter faces listed in the Coun tr y Mode featur e des cription.
ENTER/EXIT PROGRAMMING MODE Caps Lock State Product Reference Guide 59 Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 60 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the hos t. Reference Appendix E, S can co de T a bl es for more information about control characters.
ENTER/EXIT PROGRAMMING MODE Wedge Quiet Interval Product Reference Guide 61 Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 62 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Intercharacter Delay This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set with in a range of zero (0) to 990 milliseconds in 10ms increments.
ENTER/EXIT PROGRAMM ING MODE Intercode Delay Product Reference Guide 63 Intercode Delay Specifies the delay between labels transmitted to the hos t for this interface. The selectable range for this feature is from 0 to 99 seconds. See page 295 in “References” for detailed information and examples for setting this feature.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 64 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard.
ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed Product Reference Guide 65 USB Keyboard Speed — continued USB Keyboard Speed = 6ms USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed.
Keyboard Interface ENTER /EXIT PROGRAMMING MODE 66 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 NO TES.
Pr oduct R efer ence Guide 67 USB-OEM INTERFACE Feature settings for USB interfaces differ depend ing upon which host type the reader will be connected with. Use the feature settings in this chapter an d "IBM 46XX Interface"on page 69 to specifically configure for the USB-OEM inte rface.
USB-OEM Interface ENTER/EXIT PROGRAMMING MODE 68 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 USB-OEM Device Usage The USB-OEM protocol allows for the reader to be id entified as one of two different types of barcode scanners.
Pr oduct R efer ence Guide 69 IBM 46XX INTERFACE Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces.
IBM 46XX Interface ENTER/EXIT PROGRAMMING MODE 70 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 46xx Number of Host Resets Specifies how many consecutive resets are processe d before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader.
ENTER/EXIT PROGRAMMIN G MODE 46xx Number of Host Resets Product Reference Guide 71 46xx Number of Host Resets — cont. 46xx Number of Host Resets = 8 46xx Number of Host Resets = 9 46xx Number of Hos.
IBM 46XX Interface ENTER/EXIT PROGRAMMING MODE 72 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Transmit Labels in Code 39 Format This feature enable/disables tran slation to Code 39 before transmitting label data to an IBM- 46XX or a USB-OEM host. Only the symbology iden tifier is modified for the translation.
Pr oduct R efer ence Guide 73 WAND EMULATION INTERFACE This chapter provides feature/settings configuration for the Wand Emulation interface. Referenc e Appendix B, Standard Defaults for a listin g of standard factory settings.
Wand Emulation Interface E NTER/EXIT PROGRAMMING MODE 74 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Wand Signal Speed This feature specifies the speed of the Wand ou tput signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds Wand Polarity This option specifies the polarity of the Wand output signal.
ENTER/EXIT PROGRAMMING MODE Wand Idle State Product Reference Guide 75 Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle . Transmit Noise This option specifies the leading/trailing noise for the Wand interface.
Wand Emulation Interface E NTER/EXIT PROGRAMMING MODE 76 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barc ode labels are converte d to a single symbology.
Pr oduct R efer ence Guide 77 DATA FORMAT The features in this chapter can be used to build specific user-defined data into a message string. See “References” starting on page 298 for more detailed instructions on setting these features.
Data Format ENTER/EXIT PROGRAMMING MODE 78 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF.
ENTER/EXIT PROGRAMMIN G MODE Global AIM ID Product Reference Guide 79 Global AIM ID AIM label identifiers (as opposed to custom ch aracters you select yourself as with label identifiers) can be included with scanned barcode data.
Data Format ENTER/EXIT PROGRAMMING MODE 80 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-12 8 can be enable d/di sabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enable d/disabled independently as wel l.
ENTER/EXIT PROGRAMMING MODE Label ID Product Reference Guide 81 Label ID A Label ID is a customizable code of up to th ree ASCII characters (eac h can be one of hex 0x01- 0xFF), used to identify a barcode (symbology) type . It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled.
Data Format ENTER/EXIT PROGRAMMING MODE 82 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Label ID Control This option controls whether a Label ID is disabl ed, or sent as a prefix or suffix for a given symbology type.
ENTER/EXIT PROGRAMMING MODE La bel ID Symbology Selection Product Reference Guide 83 Label ID Symbology Selection This option selects the symbology for whic h a Label ID is to be configured. See "Label ID"on page 81 or page 303 in “References” for more detailed instructions.
Data Format ENTER/EXIT PROGRAMMING MODE 84 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Label ID Symbology Selection — continued Set UPC-E/GS1-128 Label ID Character(s) Set EAN 13 Label ID Characte.
ENTER/EXIT PROGRAMMING MODE La bel ID Symbology Selection Product Reference Guide 85 Label ID Symbology Selection — continued Set EAN 8/P5 Label ID Character(s) Set EAN 8/GS1-128 Label ID Char acter.
Data Format ENTER/EXIT PROGRAMMING MODE 86 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Label ID Symbology Selection — continued Set Code 32 Label ID Character(s) Set Code 39 CIP Label ID Character.
ENTER/EXIT PROGRAMMING MODE La bel ID Symbology Selection Product Reference Guide 87 Label ID Symbology Selection — continued Set Interl eaved 2 of 5 CIP HR La bel ID Character(s ) Set St andard 2 o.
Data Format ENTER/EXIT PROGRAMMING MODE 88 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Label ID Symbology Selection — continued Set Code 11 Label ID Character(s) Set DataBar Omnidirectional Label .
ENTER/EXIT PROGRAMMIN G MODE Set Global Mid Label ID Characters Product Reference Guide 89 Label ID Symbology Selection — continued Set Global Mid Label ID Characters Specifies mid-label ID that is added for transm ission between the labels of a two-label pair.
Data Format ENTER/EXIT PROGRAMMING MODE 90 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Case Conversion This feature allows conversion of the case of a ll alphabetic characters to upper or lower case. Character Conversion Character conversion is an eight byte configura tion item.
Pr oduct R efer ence Guide 91 READING PARAMETERS D OUBLE R EAD T IMEOUT on page 92 G OOD R EAD LED D URA TION on page 100 L ABEL G ONE T IMEOUT on page 93 S CAN M ODE on page 101 S LEEP M ODE T IME OU.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 92 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Double Read Timeout Double Read Timeout prevents a double read of the same labe l by setting the minimum time allowed between reads of labels of the same symbology and data.
ENTER/EXIT PROGRAMMING MODE Label Gone Timeout Product Reference Guide 93 Double Read Timeout — continued Label Gone Timeout This feature sets the time after the last label segm ent is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 94 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Sleep Mode Timeout This feature sets the amount of time that the reader will be idle before it enters into a low power Sleep Mode.
ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout Product Reference Guide 95 Sleep Mode Timeout — continued Sleep Mode Timeout = 5 Seconds Sleep Mode Timeout = 6 Seconds Sleep Mode Timeout = 7 Seconds .
Reading Parameters ENTER/EXIT PROGRAMMING MODE 96 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power.
ENTER/EXIT PROGRAMMIN G MODE Good Read Beep Type Product Reference Guide 97 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. Good Read Beep Frequency Adjusts the good read beep to sound at a selectab le low, medium or high frequency, selectable from the list below.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 98 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Good Read Beep Length Good Read Beep Length = 60 msec Good Read Beep Length = 80 msec Good Read Beep Len.
ENTER/EXIT PROGRAMMIN G MODE Good Read Beep Volume Product Reference Guide 99 Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 100 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.
ENTER/EXIT PROGRAMM ING MODE Scan Mode Product Reference Guide 101 SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 308 in “References” for descriptions.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 102 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Stand Mode Triggered Timeout This feature specifies the time to remain in Tr i g g e r S i n g l e mode after the trigger is pulled while in Stand Mode . This timeout is only used when the Sc an Mode is configured as Stand Mode.
ENTER/EXIT PROGRAMMIN G MODE Stand Detection Product Reference Guide 103 Stand Detection Specifies the behavior of the scanner when p lac ed in a stand that co ntains autorecognition hardware.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 104 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered.
ENTER/EXIT PROGRAMMIN G MODE Flash On Time Product Reference Guide 105 Flash On Time This feature specifies the ON time for the indi cator LED while in Flash Mode. The selectable range is 100 to 9,900 millise conds (0.1 to 9.9 seconds), in 100 millisecond incr ements.
Reading Parameters ENTER/EXIT PROGRAMMING MODE 106 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Green Spot Duration Specifies the duration of the good re ad pointer beam after a good read.
Pr oduct R efer ence Guide 107 CODE SELECTION The reader supports the follow ing symbologies (barcode types) . Symbology-dependent options for each symbology are in cluded in this chapter. Default settings are indicated at each feature/ op tion with a gr een arrow.
Disable All Symbologies 108 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 3. If additional input parameters are needed, go to Appendix D , Keypad , and scan the appro - priate characters from the keypad. 4. Complete the programming sequence b y scanning the ENTER/EXIT PR OGRAM - MING barcode to exit P rogramming Mode.
ENTER/EXIT PROGRAMMIN G MODE Coupon Control Product Reference Guide 109 CODE EAN/UPC Coupon Control This feature is used to control the reader ’s method of processing coupon labels.
Code EAN/UPC ENTER/EXIT PROGRAMMING MODE 110 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 UPC-A The following options appl y to the UPC-A symbology . UPC-A Enable/Disable When disabled, the reade r will not read UPC-A barcodes. UPC-A Check Character Transmission Enable this option to trans mit the che ck character along with UPC-A barcode data.
ENTER/EXIT PROGRAMMING MO DE Expand UPC-A to EAN-13 Product Reference Guide 111 Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data form at. Selecting this feature also changes the symbology ID to match those required for EAN-13.
Code EAN/UPC ENTER/EXIT PROGRAMMING MODE 112 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A lab el must be decoded before it is a ccepted as a good read.
ENTER/EXIT PROGRAMMING MODE UPC-E Enable/Disable Product Reference Guide 113 UPC-E The following options appl y to the UPC-E symb ology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. UPC-E Check Character Transmission Enable this option to trans mit the che ck character along with UPC-E barcode data.
UPC-E ENTER/EXIT PROGRAMMING MODE 114 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data form at. Selecting this feat ure also changes the symbology ID to match those required for EAN-13. Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
ENTER/EXIT PROGRAMMING MODE UPC-E Nu mber System Character Transmission Product Reference Guide 115 UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number characte r.
GTIN Formatting ENTER/EXIT PROGRAMMING MODE 116 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GTIN FORMATTING This feature enables/disables the ability to co nvert UPC-E, UP C-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
ENTER/EXIT PROGRAMMING MODE EAN 13 Enable/Disable Product Reference Guide 117 EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symb ology.
EAN 13 (Jan 13) ENTER/EXIT PROGRAMMING MODE 118 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character.
ENTER/EXIT PROGRAMMING MODE EAN 13 Minimum Reads Product Reference Guide 119 EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.
ISSN ENTER/EXIT PROGRAMMING MODE 120 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookla nd labels star ting with 977 to ISSN labels.
ENTER/EXIT PROGRAMMING MODE EAN 8 Enable/Disable Product Reference Guide 121 EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reade r will not read EAN 8/JAN 8 barcodes .
EAN 8 (Jan 8) ENTER/EXIT PROGRAMMING MODE 122 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. EAN 8 Minimum Reads This feature specifies the minimum number of consec utive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MO DE UPC/EAN Decoding Level Product Reference Guide 123 UPC/EAN GLOBAL SETTINGS This section provides configuration settin gs for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for ea ch feature description.
UPC/EAN Global Settings ENTER/EXIT PROGRAMMING MODE 124 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 UPC/EAN Correlation When correlation is enabled, the reader will combine label data from multiple scans when decoding. This will help the scanner read labels that have spots, voids and/or damaged areas.
ENTER/EXIT PROGRAMM ING MODE In-Store Minimum Reads Product Reference Guide 125 In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read.
Add-Ons ENTER/EXIT PROGRAMMING MODE 126 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ADD-ONS Contact Customer Support for advanced progra mming of optional an d conditional add-ons.
ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Product Reference Guide 127 Optional Add-On Timer This option sets the time the r eader will look for an add-on whe n an add-on fragment has be en seen and optional add-ons are enabled. (Also see "Optional G S1-128 Add-On Timer"on page 130 .
Add-Ons ENTER/EXIT PROGRAMMING MODE 128 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Optional Add-On Timer — con t. Optional Add-on T imer = 60ms Optional Add-on Timer = 70ms Optional Add-on Timer = .
ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Product Reference Guide 129 Optional Add-On Timer — con t. Optional Add-on Timer = 180ms Optional Add-on Timer = 200ms Optional Add-on Timer = 220ms.
Add-Ons ENTER/EXIT PROGRAMMING MODE 130 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons othe r than those of that type, see "Optional Add-On Timer"on page 127 .
ENTER/EXIT PROGRAMMING MODE Op tional GS1-128 Add-On Timer Product Reference Guide 131 Optional GS1-128 Add-On Timer — cont. Optional GS1-128 A dd- On Timer = 60ms Optional GS1-128 Ad d-On Timer = 7.
Add-Ons ENTER/EXIT PROGRAMMING MODE 132 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Optional GS1-128 Add-On Timer — cont. Optional GS1-128 Add-On Timer = 180ms Optional GS1-128 Ad d-On Timer = 200ms.
ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads Product Reference Guide 133 P2 Add-Ons Minimum Reads This feature specifies the minimum number of ti mes a P2 add-on must be read before it is marked as valid and then combined with a base labe l.
Add-Ons ENTER/EXIT PROGRAMMING MODE 134 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 P5 Add-Ons Minimum Reads This feature specifies the minimum number of ti mes a P5 add-on must be read before it is marked as valid and then combined with a base labe l.
ENTER/EXIT PROGRAMMING MODE GS1 -128 Add-Ons Minimum Reads Product Reference Guide 135 GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of time s an GS1-128 add- on must be read before it is marked as valid and then combined with a base labe l.
Code 39 ENTER/EXIT PROGRAMMING MODE 136 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable Code 39 Check Character Calculation Enable this option t o enables/disables calc ulatio n and verification of an optional Code 39 check character.
ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Transmission Product Reference Guide 137 Code 39 Check Character Transmission Enable this option to trans mit the check character along with Code 39 barcode data. Code 39 Check Character Calculation — cont.
Code 39 ENTER/EXIT PROGRAMMING MODE 138 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 39 Start/Stop Character Transmission Enable this option to enable/disable transm ission of Code 39 start and stop characters . Code 39 Full ASCII Enables/disables the translatio n of Code 39 characters to Code 39 full-ASCII characters.
ENTER/EXIT PROGRAMMING MODE Code 39 Quiet Zones Product Reference Guide 139 Code 39 Quiet Zones This feature specifies the number of quiet zone s for Cod e 39 labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label.
Code 39 ENTER/EXIT PROGRAMMING MODE 140 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 39 Minimum Reads This feature specifies the minimum number of consec utive times a Code 39 labe l must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MO DE Code 39 Decoding Level Product Reference Guide 141 Code 39 Decoding Level Decoding Levels are u sed to configure a barc ode symbology decoder to be ve ry aggressive to very conservative depending on a particul ar customer’s needs.
Code 39 ENTER/EXIT PROGRAMMING MODE 142 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 39 Length Control This feature specifies either vari able length decoding or fixed le ngth decoding for the Code 39 symbology. Va r i a b l e L e n g t h . For variable length decoding, a minimum and maximum length may be set.
ENTER/EXIT PROGRAMMING MODE Code 39 Set Length 1 Product Reference Guide 143 Code 39 Set Length 1 This feature specifies one of the barcode lengths for Cod e 3 9 Le n gt h Co nt ro l . Leng th 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xe d Len g t h Mode.
Code 39 ENTER/EXIT PROGRAMMING MODE 144 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 39 Set Length 2 This feature specifies one of the barcode lengths for Cod e 3 9 Le n gt h Co nt ro l . Leng th 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Product Reference Guide 145 Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels.
Code 39 ENTER/EXIT PROGRAMMING MODE 146 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 39 Interdigit Ratio — cont. Code 39 Inter digit Ratio = 6 Code 39 Interdigit Ratio = 7 Code 39 Inter digit Ra.
ENTER/EXIT PROGRAMMING MODE Co de 39 Character Cor relation Product Reference Guide 147 Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
Code 32 (ITAL Pharmaceutical Co de) ENTER/EXIT PROGRAMMING MODE 148 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes.
ENTER/EXIT PROGRAMMING MODE Co de 32 Check Char Transmission Product Reference Guide 149 Code 32 Check Char Transmission Enable this option to trans mit the check character along with Code 32 barcode data. Code 32 Start/Stop Character Transmission This option enables/disables transmission of Code 32 start and stop characters .
Code 39 CIP (French Pharmaceutic al) ENTER/EXIT PROGRAMMING MODE 150 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels.
ENTER/EXIT PROGRAMMING MO DE Code 128 Enable/Disable Product Reference Guide 151 CODE 128 The following options apply to the Cod e 128 symbology. Code 128 Enable/Disable When disabled, the reade r will not read Code 128 barcodes . Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Code 128 ENTER/EXIT PROGRAMMING MODE 152 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 128 Check Character Transmission Enable this option to trans mit the check character along with Code 128 barcode data. Code 128 Function Character Transmission Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4.
ENTER/EXIT PROGRAMMIN G MODE Code 128 Sub-Code Change Transmission Product Reference Guide 153 Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Cod e exchange” characters (NOT transmitted by standard decoding).
Code 128 ENTER/EXIT PROGRAMMING MODE 154 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 time s the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MO DE Code 128 Minimum Reads Product Reference Guide 155 Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 12 8 label must be decoded before it is accepted as good read.
Code 128 ENTER/EXIT PROGRAMMING MODE 156 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 128 Decoding Level Decoding Levels are used to configure a barcod e symbology decoder to be very aggressive to very conservative depending on a particul ar customer’s needs.
ENTER/EXIT PROGRAMMING MO DE Code 128 Length Control Product Reference Guide 157 Code 128 Length Control This feature specifies either variable length deco ding or fixed length decoding for the Code 128 symbology.
Code 128 ENTER/EXIT PROGRAMMING MODE 158 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 128 Set Length 1 Specifies one of the barcode lengths for Co d e 1 2 8 Le n g th Co n tr o l . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Len g t h Mode.
ENTER/EXIT PROGRAMMING MODE Code 128 Set Length 2 Product Reference Guide 159 Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 12 8 Length C ontrol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
Code 128 ENTER/EXIT PROGRAMMING MODE 160 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
ENTER/EXIT PROGRAMM ING MODE GS1-128 Enable Product Reference Guide 161 GS1-128 The following options apply to the GS1-128 sy mbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-12 8, EAN-128.) GS1-128 Enable This option enables/disables the ability of the re ader to translate GS1-128 labe ls to the GS1-128 data format.
Code ISBT 128 ENTER/EXIT PROGRAMMING MODE 162 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE ISBT 128 The following options apply to the ISB T 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concaten ation of 2 labels.
ENTER/EXIT PROGRAMMING MODE ISBT 128 Concatenation Mode Product Reference Guide 163 ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 C oncatenation is enabled (see page 162 ).
Code ISBT 128 ENTER/EXIT PROGRAMMING MODE 164 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
ENTER/EXIT PROGRAMMING MODE Codablock F Enable/Disable Product Reference Guide 165 CODABLOCK F The following options apply to the Codablock F symbology.
Codablock F ENTER/EXIT PROGRAMMING MODE 166 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not. Codablock F Length Control This feature specifies either variable length deco ding or fixed length de coding for the Codabl ock F symbology.
ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 1 Product Reference Guide 167 Codablock F Set Length 1 Specifies one of the barcode lengths for Codablock F L ength Control . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xed Le ng t h Mode.
Codablock F ENTER/EXIT PROGRAMMING MODE 168 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codablock F Set Length 2 This feature specifies one of the barcode lengths for Codablock F L ength Contr ol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMM ING MODE I 2 of 5 Enable/Disable Product Reference Guide 169 INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 170 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 I 2 of 5 Check Character Transmission Enable this option to trans mit the check character along with I 2 of 5 barcode data. I 2 of 5 Check Character Calculation - cont.
ENTER/EXIT PROGRAMMIN G MODE I 2 of 5 Minimum Reads Product Reference Guide 171 I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 172 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 2 of 5 Decoding Level Decoding Levels are used to configure a barcod e symbology decoder to be very aggressive to very conservative depending on a particul ar customer’s needs.
ENTER/EXIT PROGRAMMING MODE I 2 of 5 Length Control Product Reference Guide 173 I 2 of 5 Length Control This feature specifies either vari able length decoding or fixed length decoding for the I 2 of 5 symbology. Va r i a b l e L e n g t h . For variable length decoding, a minimum and maximum length may be set.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 174 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length C ontrol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xe d Len g t h Mode.
ENTER/EXIT PROGRAMM ING MODE I 2 of 5 Set Length 2 Product Reference Guide 175 I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 L ength Con trol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 176 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
ENTER/EXIT PROGRAMMING MODE Follett 2 of 5 Enable/Disable Product Reference Guide 177 FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager t o decode Follett 2 of 5 labels.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE 178 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reade r will not read Standard 2 of 5 barcodes.
ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Transmission Product Reference Guide 179 Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE 180 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard 2 of 5 Decoding Level Standard 2 of 5 Length Control This feature specifies either variable length deco ding or fixed length decoding for the Standard 2 of 5 symbology.
ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Set Length 1 Product Reference Guide 181 Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length C ontrol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Le ng t h Mode.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE 182 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length C ontrol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fi xe d Len g th Mode.
ENTER/EXIT PROGRAMMING MODE Standa rd 2 of 5 Character Correl ation Product Reference Guide 183 Standard 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
Industrial 2 of 5 ENTER /EXIT PROGRAMMING MODE 184 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 label s.
ENTER/EXIT PROGRAMM ING MODE Industrial 2 of 5 Check Character Transmission Product Reference Guide 185 Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character.
Industrial 2 of 5 ENTER /EXIT PROGRAMMING MODE 186 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length C ontrol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMM ING MODE Industrial 2 of 5 Set Length 2 Product Reference Guide 187 Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length C ontrol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fi xe d Len g th Mode.
Industrial 2 of 5 ENTER /EXIT PROGRAMMING MODE 188 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of cons ecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Character Correlation Product Reference Guide 189 Industrial 2 of 5 Character Correlation Enable/disables character correlation for Industrial 2 of 5.
Code IATA ENTER/EXIT PROGRAMMING MODE 190 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of th e reader to decode IATA labels.
ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Enable/Disable Product Reference Guide 191 DATALOGIC 2 OF 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes.
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE 192 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of co nsecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE Data logic 2 of 5 Length Control Product Reference Guide 193 Datalogic 2 of 5 Length Control This feature specifies either variable length deco ding or fixed length decoding for the Datalogic 2 of 5 symbology. Va r i a b l e L e n g t h .
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE 194 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Datalogic 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Datalogic 2 of 5 L ength Con trol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Set Length 2 Product Reference Guide 195 Datalogic 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Datalogic 2 of 5 L ength Con trol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fi xe d Len g th Mode.
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE 196 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
ENTER/EXIT PROGRAMMING MO DE Codabar Enable/Disable Product Reference Guide 197 CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reade r will not read Codabar barcodes.
Codabar ENTER/EXIT PROGRAMMING MODE 198 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Check Character Transmission Enable this option to trans mit the check character along with Codabar barcode data. Codabar Start/Stop Character Transmission Enable this option to enable/disable transm issi on of Codabar star t and stop characters .
ENTER/EXIT PROGRAMMIN G MODE Codabar Start/Stop Character Set Product Reference Guide 199 Codabar Start/Stop Character Set This option specifies the format of tr ansmitted Codabar start/stop characters . Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match .
Codabar ENTER/EXIT PROGRAMMING MODE 200 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Quiet Zones Specifies the number of quie t zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the widt h of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MO DE Codabar Minimum Reads Product Reference Guide 201 Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Cod abar label must be decoded before it is accepted as good read.
Codabar ENTER/EXIT PROGRAMMING MODE 202 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Decoding Level Decoding Levels are used to configure a barcod e symbology decoder to be very aggressive to very conservative, depending on a particular customer’s needs.
ENTER/EXIT PROGRAMMING MO DE Co dabar Length Control Product Reference Guide 203 Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Va r i a b l e L e n g t h . For variable length decoding, a minimum and maximum length may be set.
Codabar ENTER/EXIT PROGRAMMING MODE 204 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Set Length 1 This feature specifies one of the barcode lengths for Cod a b ar Le ng t h Co nt ro l . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xe d Len g t h Mode.
ENTER/EXIT PROGRAMMING MODE Codabar Set Length 2 Product Reference Guide 205 Codabar Set Length 2 This feature specifies one of the barcode lengths for Cod a b ar Le ng t h Co nt ro l . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
Codabar ENTER/EXIT PROGRAMMING MODE 206 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Interdigit Ratio This feature specifies the ratio between an inte rcharacter space and module for Codabar labels.
ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio Product Reference Guide 207 Codabar Interdigit Ratio — cont. Codabar Interdigit Ratio = 6 Codabar Interdigit Ratio = 7 Codabar Interdigit Ratio =.
Codabar ENTER/EXIT PROGRAMMING MODE 208 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
ENTER/EXIT PROGRAMMING MODE ABC Codabar Enable/Disable Product Reference Guide 209 ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
ABC Codabar ENTER/EXIT PROGRAMMING MODE 210 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
ENTER/EXIT PROGRAMMING MODE ABC Codabar Force Concatenation Product Reference Guide 211 ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
Code 11 ENTER/EXIT PROGRAMMING MODE 212 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes.
ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission Product Reference Guide 213 Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character.
Code 11 ENTER/EXIT PROGRAMMING MODE 214 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 11 Length Control This feature specifies either vari able length decoding or fixed le ngth decoding for the Code 11 symbology. Va r i a b l e L e n g t h . For variable length decoding, a minimum and maximum length may be set.
ENTER/EXIT PROGRAMMING MODE Code 11 Set Length 1 Product Reference Guide 215 Code 11 Set Length 1 This feature specifies one of the barcode lengths for Cod e 1 1 Le n gt h Co nt ro l . Leng th 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xe d Len g t h Mode.
Code 11 ENTER/EXIT PROGRAMMING MODE 216 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 11 Set Length 2 This feature specifies one of the barcode lengths for Cod e 1 1 Le n gt h Co nt ro l . Leng th 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Product Reference Guide 217 Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels.
Code 11 ENTER/EXIT PROGRAMMING MODE 218 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 11 Interdigit Ratio — cont. Code 11 Inter digit Ratio = 6 Code 11 Interdigit Ratio = 7 Code 11 Inter digit Ra.
ENTER/EXIT PROGRAMMING MO DE Code 11 Decoding Level Product Reference Guide 219 Code 11 Decoding Level Decoding Levels are u sed to configure a barc ode symbology decoder to be ve ry aggressive to very conservative depending on a particul ar customer’s needs.
Code 11 ENTER/EXIT PROGRAMMING MODE 220 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help th e scanner read labels th at have some spots and/ or voids.
ENTER/EXIT PROGRAMMING MODE GS1 Data Bar™ Omnidirectional Enable/Disable Product Reference Guide 221 GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 Da taBar™ Omnidirectional (formerly RSS-14) symbology.
GS1 DataBar™ Omnidirectiona l ENTER/EXIT PROGRAMMING MODE 222 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GS1 DataBar™ Omnidirectional Minimum Reads This feature specifies the minimum number of consec utive times a GS1 DataBar™ Omnidirectional label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MODE GS1 Da taBar™ Expanded Enable/Disable Product Reference Guide 223 GS1 DATABAR™ EXPANDED The following options apply to the GS1 Da taBar™ Expanded (formerly RSS Expanded) symbology. GS1 DataBar™ Expanded Enable/Disable When disabled, the reade r will not re ad GS1 DataBar™ Expanded barcodes.
GS1 DataBar™ Expanded ENTE R/EXIT PROGRAMMING MODE 224 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GS1 DataBar™ Expanded Minimum Reads This feature specifies the minimum number of consec utive times a GS1 DataBar™ Expanded label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Set Length 1 Product Reference Guide 225 GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length C ontrol .
GS1 DataBar™ Expanded ENTE R/EXIT PROGRAMMING MODE 226 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length C ontrol .
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Enable/Disable Product Reference Guide 227 GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reade r will not read GS1 DataBar™ Limited barcodes.
GS1 DataBar™ Limited ENT ER/EXIT PROGRAMMING MODE 228 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consec utive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read .
ENTER/EXIT PROGRAMMING MO DE Code 93 Enable/Disable Product Reference Guide 229 CODE 93 The following options apply to the Code 93 symbology. Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels. Code 93 Check Character Calculation Enables/disables calculat ion and verification of an optional Code 93 check character.
Code 93 ENTER/EXIT PROGRAMMING MODE 230 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. Code 93 Length Control This feature specifies either vari able length decoding or fixed le ngth decoding for the Code 93 symbology.
ENTER/EXIT PROGRAMMING MODE Code 93 Set Length 1 Product Reference Guide 231 Code 93 Set Length 1 Specifies one of the barcode lengths for Cod e 93 Len g th Con tr ol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Le ng t h Mode.
Code 93 ENTER/EXIT PROGRAMMING MODE 232 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 93 Set Length 2 This feature specifies one of the barcode lengths for Cod e 9 3 Le n gt h Co nt ro l . Leng th 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMMING MO DE Code 93 Minimum Reads Product Reference Guide 233 Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.
Code 93 ENTER/EXIT PROGRAMMING MODE 234 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 93 Decoding Level Specifies the decoding level for Code 93. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending o n a particular customer’s needs.
ENTER/EXIT PROGRAMMING MODE Code 93 Quiet Zones Product Reference Guide 235 Code 93 Quiet Zones Enables/disables quiet zones for Code 93. Code 93 Quiet Z ones = No Quiet Zones Code 9 3 Quiet Z ones = .
Code 93 ENTER/EXIT PROGRAMMING MODE 236 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93.
ENTER/EXIT PROGRAMMING MODE MSI Enable/Disable Product Reference Guide 237 MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of re ader to decode MSI labels. MSI Check Character Calculation Enables/Disables calculation and verificat ion of an optional MSI check character.
MSI ENTER/EXIT PROGRAMMING MODE 238 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 MSI Check Character Transmission Enables/disables transm ission of an MSI check character. MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology.
ENTER/EXIT PROGRAMMING MODE MSI Set Length 1 Product Reference Guide 239 MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length C ontrol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fixe d Len gt h Mode.
MSI ENTER/EXIT PROGRAMMING MODE 240 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Co ntrol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fi xed Len g th Mode.
ENTER/EXIT PROGRAMMING MODE MSI Minimum Reads Product Reference Guide 241 MSI Minimum Reads This feature specifies the mini mum number of consecutive tim es an MSI label must be decoded before it is accepted as good read.
MSI ENTER/EXIT PROGRAMMING MODE 242 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 MSI Decoding Level Specifies the decoding level for MSI. Decodi ng Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending o n a particular customer’s needs.
ENTER/EXIT PROGRAMMIN G MODE MSI Stitching Product Reference Guide 243 MSI Stitching Enables/disables fixed length stitching for MSI. MSI Character Correlation Enables/disables Character Correlation for MSI.
Plessey ENTER/EXIT PROGRAMMING MODE 244 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of read er to decode Plessey labels.
ENTER/EXIT PROGRAMMING MODE Plessey Check Character Calculation Product Reference Guide 245 Plessey Check Character Calculation Enables/Disables calculation and verificatio n of an optional Plessey check character. Plessey Check Character Transmission Enables/disables transmission of an MSI check character.
Plessey ENTER/EXIT PROGRAMMING MODE 246 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Va r i a b l e L e n g t h . For variable length decoding, a minimum and maximum length may be set.
ENTER/EXIT PROGRAMMING MO DE Plessey Set Length 1 Product Reference Guide 247 Plessey Set Length 1 This feature specifies one of the barcode lengths for Plessey Length C ontrol . Length 1 is the minimum label length if in Va r i a b l e L e n g t h Mode, or the first fixed length if in Fi xe d Len g t h Mode.
Plessey ENTER/EXIT PROGRAMMING MODE 248 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Plessey Set Length 2 This feature specifies one of the barcode lengths for Plessey Length C ontrol . Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fixe d Le ng t h Mode.
ENTER/EXIT PROGRAMMING MO DE Pl essey Minimum Reads Product Reference Guide 249 Plessey Minimum Reads This feature specifies the minimum number of conse cutive times a Plessey label must be decoded before it is accepted as good read.
Plessey ENTER/EXIT PROGRAMMING MODE 250 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Plessey Decoding Level Specifies the decoding level for Plessey. Deco ding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending o n a particular customer’s needs.
ENTER/EXIT PROGRAMMING MODE Plessey Stitching Product Reference Guide 251 Plessey Stitching Enables/disables fixed length stitching for Plessey. Plessey Character Correlation Enables/disables Character Correlation for Plessey.
Code 4 ENTER/EXIT PROGRAMMING MODE 252 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 CODE 4 The following options apply to the Cod e 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager t o decode Code 4 labels. Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character.
ENTER/EXIT PROGRAMMIN G MODE Code 4 Hex to Decimal Conversion Product Reference Guide 253 Code 4 Hex to Decimal Conversion This feature enables/disables the conver sion of hexidecimal label data to decimal label data. CODE 5 The following options apply to the Cod e 5 symbology.
Code 5 ENTER/EXIT PROGRAMMING MODE 254 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. Code 5 Hex to Decimal Conversion This feature enables/disables the conver sion of hexidecimal label data to decimal label data.
ENTER/EXIT PROGRAMMING MODE Co de 4 and 5 Decoding Level Product Reference Guide 255 CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS The following options apply to both Code 4 and Code 5 symbologies.
Code 4 and Code 5 Common Configurati on Items ENTER/EXIT PROGRAMMING MODE 256 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Code 4 and Code 5 Minimum Reads This feature specifies the minimum number of co nsecutive times a Cod e 4 or Code 5 label must be decoded before it is accepted as good read.
Pr oduct R efer ence Guide 257 Chapter 4 W ireless F eatur es This section provides options and programming related to the reader’s STAR and Bluetooth communication features. Reference Appendix B, Standar d Defaults for a list ing of standard factory settings.
Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE 258 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 WIRELESS BEEPER FEATURES Several options are a vailable to configure beeper behavior for RF operation. Good Transmission Beep Enables/disables the Good Tr ansmission Beep in dication.
ENTER/EXIT PROGRAMMIN G MODE Beep Duration Product Reference Guide 259 Beep Duration This feature controls the duration of radio-specific beep indications .
Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE 260 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Beep Volume Selects the beeper volume (loudness) of radio-specific beep indications.
ENTER/EXIT PROGRAMMING MODE Base Station Beep Product Reference Guide 261 Base Station Beep Enables/disables a beep indicat ion when the handheld is placed in the Base Station . Leash Alarm This setting specifies the number of seconds to sound the Leash Mode beeps (th ree per second) when the handheld go es out of range.
Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE 262 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Leash Alarm — cont. Leash Alar m = 3 Seconds Leash Alar m = 4 Seconds Leash Alar m = 5 Seconds .
ENTER/EXIT PROGRAMMIN G MODE Automatic Configuration Update Product Reference Guide 263 CONFIGURATION UPDATES See page 312 in “References” for detailed information and examples of these features.
Configuration Updates ENTER/EXIT PROGRAMMING MODE 264 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Copy Configuration to Base Station Scan the following label to copy the current scanner configuration to the Base Station.
ENTER/EXIT PROGRAMMING MODE Request Flash Update Product Reference Guide 265 Request Flash Update Scan this barcode to request a flash update from a Base Station Powerdown Timeout The Powerdown Timeout feature sets the time for automatically switching the unit off when the imager has been idle.
Configuration Updates ENTER/EXIT PROGRAMMING MODE 266 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Powerdown Timeout — continued Po werdown T imeout = 60 Minutes (1 Hour) P owerdo wn Timeout = 120 .
ENTER/EXIT PROGRAMMING MODE Batch Mode Product Reference Guide 267 BATCH FEATURES Batch Mode This option specifies whether to store labels in the handheld while disconnected from the base. Options are as follows: • Disabled — The handheld will not store/batch labels.
Batch Features ENTER/EXIT PROGRAMMING MODE 268 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Erase Batch Memory Use this barcode to erase any labels stored in batch memory. RF Batch Mode Transmit Delay Specifies the delay in 10 msec increments between transmitting labels stored in batch memory .
ENTER/EXIT PROGRAMMIN G MODE Source Radio Address Transmission Product Reference Guide 269 RF ADDRESS STAMPING These features allow configuration of source radio data inclusion.
RF Address Stamping ENTER/EXIT PROGRAMMING MODE 270 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Features for Star Models Only The features in this section are valid only for the Gryphon I GM4100 Sta.
ENTER/EXIT PROGRAMMING MODE STAR Radio Transmit Mode Product Reference Guide 271 Options are: • ACK from cradle to scanner — signals a good transmission as soon as the Base S tation receiv es a la.
Display Features ENTER/EXIT PROGRAMMING MODE 272 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 DISPLAY FEATURES Contrast Read the code until the desired contrast is reached.
ENTER/EXIT PROGRAMM ING MODE Backlight Product Reference Guide 273 Backlight Display Mode The user can control the reader d isplay behavior according to various selections.
Display Features ENTER/EXIT PROGRAMMING MODE 274 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Display Timeout Specifies how long the display will remain on after a display write. Display is forced on after any display write or after any reading phase.
ENTER/EXIT PROGRAMMING MODE Display Timeout Product Reference Guide 275 Display Timeout - cont. Display Timeout = 5 Seconds Display Timeo ut= 6 Se conds Display Timeout = 7 Seconds Display T imeout = 8 Seconds Display Timeout = 9 Seconds Display T imeout = 9.
Display Features ENTER/EXIT PROGRAMMING MODE 276 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Keypad Select This parameter specifies the character that has to be sent from the scanner when one of the three keys are pressed. For example, when key1 is pressed a 0x3C '< ' character is sent.
ENTER/EXIT PROGRAMMING MODE BT Security Mode Product Reference Guide 277 Bluetooth-Only Features The features in this section are valid only for Gryphon Bluetooth mode ls. Also reference the Setup section for instructions on Linking a B T Reader to a PC, star ting on page 25 .
BT Security Features ENTER/EXIT PROGRAMMING MODE 278 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 BT Pin Code This option specifies the 4-character pin code to be used for authentication of the BT link. "BT Security Mode"on page 277 mu st first be enabled to require the pin code.
ENTER/EXIT PROGRAMMING MODE BT Poll Rate Product Reference Guide 279 OTHER BT FEATURES BT Poll Rate This feature specifies th e time between BT polls. BT Poll Rate = Maximu m BT Poll Rate BT P oll Rat.
Other BT Features ENTER/EXIT PROGRAMMING MODE 280 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 BT Poll Rate (continued) BT P oll Rate = 150 ms BT P oll Rate = 200 ms BT P oll Rate = 500 ms BT P oll R.
Pr oduct R efer ence Guide 281 Chapter 5 Laser F eatur es The features in this section are valid for the Gryphon L GD4300 model only. This section provides options and programming related to the reader’s laser features. Referenc e Appendix B, Standard Defaults for a listin g of standard factory settings.
Laser Features ENTER/EXIT PROGRAMMING MODE 282 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Laser Scan Angle This feature se ts the scan angle for the laser. The Narrow scan angle is helpful for selecting and reading a specific barcode amon g a tight grouping of labels.
ENTER/EXIT PROGRAMMING MODE Bi-Directional Read Decoding Product Reference Guide 283 Bi-Directional Read Decoding This configuration provides control over the good read and barcode label requirement. This programming option for Gyphon Laser affects all barcode symbologies.
Laser Features ENTER/EXIT PROGRAMMING MODE 284 Gryphon™ I GD4100/GM4100/GBT 4100 /L GD4300 Always On Scan Mode Timeout When the Gryphon Laser is in Always On scanni ng mode, timeout periods can be configured. If the programmed Always On Timeout elapses, th e reader will shut down and a trigger pull is required to resume operation.
Pr oduct Referenc e Guide 285 Chapter 6 Ref erenc es This section contains explanations and exam ples of selected barcode features. See the Configuration section for the actual barcod e labels used to configure the reader. RS-232 Par ameters RS-232 Only Baud Rate Baud rate is the number of bits of data transmitted per second.
References 286 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 • R TS/XON/X OFF — R TS is asse rted during transmissions. CTS is ignor ed. XON and X OFF gate transmissions. • R T S On/CTS — R TS is always asserted. CTS gates transmissions. R T S/CTS Scan Control — R TS is asserted during transmissions.
RS-232 Parameters Product Reference Guide 287 A CK NAK Options This enables/disables the ability of the read er to support the RS-2 32 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” wh en it receives data properly, and sends “NAK” when the data is in error.
References 288 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. To set this feature: 1. Determine the desire d character or value.
RS-232 Parameters Product Reference Guide 289 2. Divide the desired setting by 200 (setting is in 200ms increme nts). P ad the result with leading zeroes to yield two digits. F or example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 51 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter P rogramming M ode.
References 290 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 5. Scan the appropriate three digits from the keypad in Appendix D Keypad , that represent the number which was determined in the steps abo ve. Y ou will hear a two-beep indication after the last character .
RS-232 Parameters Product Reference Guide 291 Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected . To set the value: 1. Determine the desired character or value.
References 292 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Enable Character Specifies the value of the RS -232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selecte d. To set this feature: Determine the desired character or value.
Keyboard Interface Product Reference Guide 293 Key b o a r d I n t e r f a c e We d g e Q u i e t I n t e r v a l Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host.
References 294 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Inte rchar acter Delay This parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set with in a range of zero (0) to 990 milliseconds in 10ms increments.
Keyboard Interface Product Reference Guide 295 Inte rc ode Delay Specifies the delay between labels transmitted to the hos t for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feat ure: 1.
References 296 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 S ymbologies Decoding Le vel Decoding Levels are used to configure a barcod e symbology decoder to be very aggressive to very conservative depending on a particul ar customer’s needs.
Symbologies Product Reference Guide 297 Set Length 2 This feature allows you to set one of the barcod e lengths for the specifie d symbology. Length 2 is the maximum label length if in Va r i a b l e L e n g t h Mode, or the second fixed length if in Fi x e d Length Mode.
References 298 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Data Editing When a barcode is scanned, additional informatio n can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.
Data Editing Product Reference Guide 299 Global Pr efix/Suffix Up to 20 ASCII characters may be added as a prefix (in a positi on before the barcode data) and/ or as a suffix (in a position following the barcode data) as indicated in Figure 17 . F igure 17.
References 300 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Global AIM ID AIM label identifiers (as opposed to custom ch aracters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), follo wed by .
Data Editing Product Reference Guide 301 Label ID A Label ID is a customizable code of up to th ree ASCII characters (eac h can be one of hex 0x01- 0xFF), used to identify a barcode (symbology) type . It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled.
References 302 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Label ID Pre-Loaded Sets (continued ) Symbology USA Label ID set EU Label ID set ASCII character Hexidecimal value ASCII character Hexidecima.
Data Editing Product Reference Guide 303 Label ID: Set Individually Pe r Symbology To configure a Label ID individually for a single symbology: 1. Go to page 81 and scan the ENTER/EXIT barcode.
References 304 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Ta b l e 39 . Label ID Examples STEP AC T I O N EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2.
Data Editing Product Reference Guide 305 Character C onv ersion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted.
References 306 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Reading P arameters Label Gone T imeout This feature sets the time after the last label segm ent is seen before the reader prepares for a ne w label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.
Reading Parameters Product Reference Guide 307 Good Read LED Dura tion This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.
References 308 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Scanning F eatures Scan Mod e This mode is associated with typical handheld re ader operation. Sele cts the scan operating mode for the reader. The following selections are valid for all models: T rigger Sing le.
Scanning Features Product Reference Guide 309 Scanning Activ e T ime This setting specifies the amount of time t hat the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
References 310 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Fl as h O n Tim e This feature specifies the ON time for the indi cator LED while in Flash Mode. The selectable range is 100 to 9,900 millise conds (0.1 to 9.9 seconds), in 100 millisecond incr ements.
Scanning Features Product Reference Guide 311 Fl as h O f f Tim e This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 millise conds (0.1 to 9.9 seconds), in 100 millisecond incr ements. Follow these instructions to set this feat ure.
References 312 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Displa y Settings Display Mode The user can control the reader display beha vior according to the following selections: Local Echo mode: When a barcode is read with the reader: • The code is sent to the Host.
RF Features Product Reference Guide 313 Follow these instructions to select the delimiter character: 1. Determine the desired character , then find its hexadecimal equivalent on the ASCII Char t on the inside back cover . A settin g of 00 specifies no delimiter character .
References 314 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ST AR Radio Protocol T imeout This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed. When setting this parameter, take into consider ation the radio traffic (n um ber of readers in the same area).
RF Features Product Reference Guide 315 BT - O n l y Fe a t u re s BT Pi n Co d e This option specifies the 4-character pin code to be used for authentication of the BT link. "BT Sec ur i ty Mode "o n pa ge 277 must first be enabled to require the pin code.
References 316 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NO TES.
Pr oduct Referenc e Guide 317 Chapter 7 Message F ormatting Message F ormatting A message from the Host to the base must follow these rules: • If Address stamping options or address delimi ter are enabled on the base, the H ost replay must have address field and delimiter too.
Message Formatting 318 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 • If you want to control the Scanner's beeper fr om the host, you will also probably want to disable the good transmission beep that is em itted when the code is received from the cra - dle.
Message Formatting Product Reference Guide 319 Clearing Di splay LED and Beeper Con trol The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper . The LED and Beeper will be controlled by the system after the entire comman d sequence is interpreted.
Message Formatting 320 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Messages from Scanner C ommand K ey s T h e G r y p h o n ™ I s e r i e s s c a n n e r s w i t h d i s p l ay h a v e 3 c o m m a n d k e y s t h a t c a n e a c h b e a s s o c i a t e d with a character to send to the host.
Prod u c t Re fer e nce G ui d e 321 Ap pe nd i x A T echnical Specifications Table 48 contains Physical and Perf ormance Characteristics, User Environment and Regulatory information.
Technical Specifications 322 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Operating autonomy (continuous reading) GM4100: 50,000 reads (typical) GB T4100: 30,000 reads (typical) Performanc e Charac.
Technical Specifications P roduc t Refere nce Guide 323 Regulatory Electrical Safety See the Quick Reference Guide f or each specific product for details. EMI/RFI Laser Safety LED class safety a. T ypical input curr ent measur ed under factory default configura tion.
Technical Specifications 324 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Standard C able Pinouts Fig u r e 20 and Table 49 provide standard pinout informatio n for the Base Station’s interface cable. Figure 2 0. Stand ard Ca ble Pinout s The signal descriptions in Table 49 apply to the connector on th e reader and are for reference only.
Technical Specifications P roduc t Refere nce Guide 325 LED and Beeper Indications The reader’s beeper sounds and its LED illuminate s to indicate various functions or errors on the reader. An optional “Green Sp ot” also performs useful functions.
Technical Specifications 326 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Ta b l e 51 . Programming Mode Indications Error C o des Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field R epl aceable Unit) isolation mode.
Technical Specifications P roduc t Refere nce Guide 327 Base Station Indica tions INDICA TION LEDS Pow e r- u p C o mp l e t e Ye l l o w L E D o n Reader Disabled by the HOST or the communication wit.
Technical Specifications 328 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NO TES.
Pr oduc t Referenc e Guide 329 Ap p e n di x B Standa rd Defa ult s The most common configuration settings are listed in the “Default” column of the table below. Page references are also provid ed for feature descriptions and programming barcodes for each parameter.
Standard Defaults 330 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 ACK NAK Err or Handling Ign o re Er ro rs D ete c te d 52 Indicate T ransmission F ailur e Enable 52 Disable Character ‘D’ 53 Enable Character ‘E’ 53 KEYBO ARD WEDGE Cou n t r y M od e U.
Standard Defaults P roduc t Refere nce Guide 331 Global AIM ID Disabl e 79 GS1-128 AIM ID Enable 80 Label ID: Pre-lo aded Sets USA Set 81 Label ID Contr ol Disabl e 82 Set Global M id Label ID Charac ters No Mid Label ID Character 89 Case C onv ersion Disabl e 90 Character Con version No Char Conversion 90 READING P ARAMETERS Double Read Timeout 0.
Standard Defaults 332 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 UPC-A Check Character T ransmission Enable 110 Expand UPC-A to EAN-13 Don’ t Expand 111 UPC-A Number S ystem Character T ransmission.
Standard Defaults P roduc t Refere nce Guide 333 Add-Ons Optional Add-ons Disable P2, P5 and P8 126 Optional Add-On Timer 70 ms 127 Optional GS1-128 A dd-On Timer Disabl e 130 P2 Add-Ons Minimum Read .
Standard Defaults 334 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Expand Code 128 to Code 3 9 Don’ t Expand 151 Code 128 Check Character T ransmission Send 152 Code 128 F unction Character T ransmis.
Standard Defaults P roduc t Refere nce Guide 335 I 2 of 5 Minimum Reads 2 192 2 of 5 Decoding L evel 3 192 I 2 of 5 Length Control Va r i a b l e 173 I 2 of 5 Set Length 1 12 174 I 2 of 5 Set Length 2.
Standard Defaults 336 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Industrial 2 of 5 Character C orrela tion Disabl e 189 Cod e I A T A IA T A Enable/Disable Disabl e 190 IA T A Check Character T ransm.
Standard Defaults P roduc t Refere nce Guide 337 ABC Codabar ABC Codabar Enable/Disable Disabl e 209 ABC Codabar C oncatenation Mode Static 209 ABC Codabar Dynamic C oncatenation Timeout 200 msec 210 .
Standard Defaults 338 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 GS1 DataBar™ Limit ed Minimum Reads 1 228 Cod e 9 3 Code 93 Enable/Disable Disabl e 229 Code 93 Check Character Calculat ion Enable .
Standard Defaults P roduc t Refere nce Guide 339 Plessey Set Le ngth 2 50 248 Plessey Minimum Reads 4 249 Plessey Decoding L evel 3 250 Plessey Stitching Disabl e 251 Plessey Character Correlation Dis.
Standard Defaults 340 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Source Radio A ddress Delimiter Char ac ter Enable 269 Features for Star Models On ly ST AR Radio Protocol Timeout 2 seconds 270 ST AR.
Pr oduc t Referenc e Guide 341 Ap pe nd i x C Sample Barc odes The sample barcodes in this appendix are typical representations for their symbology types.
Sample Barcodes 342 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Sampl e Bar code s — c on tinued Code 32 Codabar Code 93 Code 1 1 A 0200 96020.
Sample Barcodes P roduc t Refere nce Guide 343 GS1 DataBar™ (RSS ) GS1 DataBar™-14 GS1 DataBar™ variants must be enabled t o read the barcodes belo w (see GS1 DataBar™ Omnidirectional on page 221 ).
Sample Barcodes 344 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NO TES.
Pr oduc t Referenc e Guide 345 Ap p e n di x D Ke y p a d Use the barcodes in this appendix to enter numbers as you would sel ect digits/characters from a keypad.
Keypad 346 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 6 7 8 9.
Keypad P roduc t Refere nce Guide 347 A B C D E F.
Keypad 348 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NO TES.
Pr oduct Referenc e Guide 349 Ap pe nd i x E Sc ancode T ables C ontrol Char ac ter Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detail ed by interface type in the tables.
350 Gryphon™ I GD4100/GM4 100/GBT4100/L GD4300 Inter face T ype PC A T PS/2, USB -Ke yboard or USB-Ke yboard f or APPLE Ta b l e 53. Sc ancode Set When Con trol Charac ter is 00 or 01 Extended ch aracters (sky bl ue) are sent through dedicated keys (when availabl e in the selec ted countr y mode) or by using an Alt Mode sequence.
351 Gryphon™ I GD4100/GM4 100/GBT4100/L GD4300 Inter face T ype PC A T PS/2, USB -Keyboa rd or USB -Ke yboard for APPLE — cont. Ta b l e 54. Sc ancode Set When Control Char ac ter is 02 x0 x1 x2 x.
Pr oduc t Refer ence Guide 352 Inter face type PC A T PS/2 Alt Mode or USB-Ke yboard Alt Mode Ta b l e 55. Sc ancode Set When Con trol Charac ter is 00 or 01 x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB xC xD .
353 Gryphon™ I GD4100/GM4 100/GBT4100/L GD4300 Inter face typ e PC A T PS/2 Alt Mode or USB -Ke yboard Alt Mode — c ont . Ta b l e 56. Sc ancode Set When Control Char ac ter is 02 x0 x1 x2 x3 x4 x.
Pr oduc t Refer ence Guide 354 Digital Inter face Ta b l e 57. Sc ancode Set When Con trol Character is 00 or 01 Ta b l e 58. Sc ancode Set When Control Char ac ter is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9.
355 Gryphon™ I GD4100/GM4 100/GBT4100/L GD4300 IBM31xx 102-ke y Ta b l e 59. Sc ancode Set When Con trol Character is 00 or 01 Ta b l e 60. Sc ancode Set When Control Char ac ter is 02 X0 x1 x2 x3 x.
Pr oduc t Refer ence Guide 356 IBM XT Ta b l e 61. Sc ancode Set When Con trol Character is 00 or 01 Ta b l e 62. Sc ancode Set when Control Charac ter 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE .
Scancode Tables Product Reference Guide 357 Microsoft W indow s C odepage 1252 Windows-1252 is a character encoding of th e Latin alphabet, used by default in the legacy components of Microsoft Window s in English and some other Western languages.
Scancode Tables 358 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 NO TES.
Prod u c t R e fer en ce G ui de 359 Ind e x A Aladdin™ 16 B barcodes cancel 3 45 numeric barcodes 3 45 RS-232 bau d r a te 64 RS-232 parameters p a rit y 5 8 , 177 , 252 , 25 3 , 256 battery WARNIN.
360 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300 Index N numbers lock key 59 P Performance Characteristics 3 22 Physical Characteristics 3 21 Pitch – Good Read, Beeper 97 Polarity (wand) 74 Prefix/Su.
ASCII Char t ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . Hex No . ASCII Char . He x No . NUL SOH STX ETX EO T ENQ AC K BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM S.
Datalogic Scanning, Inc. 959 T err y Street Eugene, OR 97402 USA T elephone: (541) 683-5700 F ax: (541) 345-7140 ww w .scanning.da talogic.com Austr alia Datalogic Scanning Pt y Ltd T elephone: [61] (2) 9870 3200 australia.scanning@datalogic .com F rance and Benelux Datalogic Scanning SAS T elephone: [33].
デバイスDatalogic Gryphon GM4130の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Datalogic Gryphon GM4130をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDatalogic Gryphon GM4130の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Datalogic Gryphon GM4130の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Datalogic Gryphon GM4130で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Datalogic Gryphon GM4130を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDatalogic Gryphon GM4130の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Datalogic Gryphon GM4130に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDatalogic Gryphon GM4130デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。