Operating Instructions & Parts Manual Description Dayton professional-duty generators ar e rugged and compact. These models provide dependable, trouble-fr ee service. The alternators are brushless with revolving fields. Y anmar diesel engines provide long life under heavy use.
Dayton Operating Instructions and Parts Manual 2 Dayton Diesel Electric Generator ® 4W315C 107358 Specifications Rated Maximum Rated Amperage Rated Amperage W attage* V A 120V 240V 5000 6500 41.7 20.8 ELECTRICAL SPECIFICA TIONS * Single-phase, 1.0 power factor NOTE: Ratings apply to SAE standard conditions.
Dayton Operating Instructions and Parts Manual 3 Model 4W315C Version B - For Reduction G016.J ® 107358 EF R U N S T O P E F 1 2 0 O N L Y F U L L P O W E R O U T P U T V O L T A G E A C V O L T S 0 .
Dayton Operating Instructions and Parts Manual 4 Dayton Diesel Electric Generator ® 4W315C 107358 General Safety Information Engine exhaust contains poisonous carbon monoxide gas. Overexposur e will cause loss of consciousness and will lead to death.
Dayton Operating Instructions and Parts Manual 5 Model 4W315C Version B - For Reduction G016.J ® 107358 Battery contains sulfuric acid. Battery acid is poisonous if swallowed. Contact with skin or eyes may cause severe burns. Do not tilt generator with battery installed.
Dayton Operating Instructions and Parts Manual 6 Dayton Diesel Electric Generator ® 4W315C 107358 Generator Features (Continued) FULL POWER SELECTOR SWITCH The full power selector switch is on the control panel. The switch has two posi- tions: 120 VOL T ONL Y , and 120/240 VOL T .
Dayton Operating Instructions and Parts Manual 7 Model 4W315C Version B - For Reduction G016.J ® 107358 RECEPT ACLE CIRCUIT BREAKER The circuit br eakers protect the r eceptacles and alternator . Overloading generator will trip circuit br eaker . A short circuit in item being powered will also trip br eaker .
Dayton Operating Instructions and Parts Manual 8 Dayton Diesel Electric Generator ® 4W315C 107358 • Do not overfill fuel tank. Always allow room for fuel to expand. If you overfill tank, fuel can overflow onto hot engine. This can cause fire. After r efueling, tightly close fuel tank cap.
Dayton Operating Instructions and Parts Manual 9 Model 4W315C Version B - For Reduction G016.J ® 107358 Oil Level At T op Of Filler Neck Dipstick Oil Figure 14 – Checking Oil Level Installation (Continued) Lube Oil Capacity: 4W315C 1.
Dayton Operating Instructions and Parts Manual 10 Dayton Diesel Electric Generator ® 4W315C 107358 IMPORT ANT : This generator will not power your entire home. Most home utility electric service is more than 60 amps. This will exceed generator output.
Dayton Operating Instructions and Parts Manual 11 Model 4W315C Version B - For Reduction G016.J ® 107358 TYPICAL ELECTRIC APPLIANCE WA TT AGES Chart to be used as a refer ence. Data may vary with size, make, and/or model. CHART 1 Starting Running W atts Equipment W atts (Max.
Dayton Operating Instructions and Parts Manual 12 Dayton Diesel Electric Generator ® 4W315C 107358 W (Neutral) X (Hot) Ground (Green) 120 Volt 30 Amp G W X L5-30P Plug Operation HIGH AND LOW TEMPERA TURE OPERA TION Air temperature af fects generator output.
Dayton Operating Instructions and Parts Manual 13 Model 4W315C Version B - For Reduction G016.J ® 107358 Operation (Continued) BLEEDING FUEL LINE 1. Loosen fuel line clamp and remove fuel line from engine. Place open end of fuel line over a clean container to catch any fuel spilled in step 3, below .
Dayton Operating Instructions and Parts Manual 14 Dayton Diesel Electric Generator ® 4W315C 107358 RUN STOP Engine Stop Lever Figure 23 - Pushing Down Engine Stop Lever Figure 22- Decompr ession Lever Decompression Lever b. Recoil Starter (1) Slowly pull starter rope until you feel strong r esistance.
Dayton Operating Instructions and Parts Manual 15 Model 4W315C Version B - For Reduction G016.J ® 107358 O S Fuel V alve Lever Figure 24 - Fuel V alve Lever In “S” Position Maintenance and Repairs Only a qualified electrical service person should service and repair the alternator on this generator .
Dayton Operating Instructions and Parts Manual 16 Dayton Diesel Electric Generator ® 4W315C 107358 NOTE: Much more fluid is lost during summer than in winter . Before starting, check for physical damage to the battery and also the electrolyte levels, and replenish with distilled water up to the upper mark if necessary .
Dayton Operating Instructions and Parts Manual 17 Model 4W315C Version B - For Reduction G016.J ® 107358 Special tools and skills requir ed. No special tools or skills requir ed. Service Service Service Service First Every Every Every Daily Service Month 3 Months 6 Months Y ear Item Check Monthly or 20 Hrs.
Dayton Operating Instructions and Parts Manual 18 Dayton Diesel Electric Generator ® 4W315C 107358 Wiring Diagrams Circuit Breaker 25A 120/240V 20A Receptacle T4 120V, 15A Receptacle 120V, 30A Recept.
Dayton Operating Instructions and Parts Manual 19 Model 4W315C Version B - For Reduction G016.J ® 107358 Tr oubleshooting Chart Only a qualified electrical service person should service and repair generator . Use only factory approved r eplacement parts.
Dayton Operating Instructions and Parts Manual 20 Dayton Diesel Electric Generator ® 4W315C 107358 For Repair Parts, call 1-800-323-0620 24 hours a day - 365 days a year 4W315C E F 3 1 2 4 5 18 19 14.
Dayton Operating Instructions and Parts Manual 21 Model 4W315C Version B - For Reduction G016.J ® 107358 Repair Parts List for Fuel T ank and Roll Cage 4W315C Reference Part No.
Dayton Operating Instructions and Parts Manual 22 Dayton Diesel Electric Generator ® 4W315C 107358 4W315C 1 6 2 10 12 15 16 13 14 17 18 19 20 21 23 23 22 3 9 8 4 7 5 11 24 Figure 29 – Repair Parts .
Dayton Operating Instructions and Parts Manual 23 Model 4W315C Version B - For Reduction G016.J ® 107358 Repair Parts List for Alternator Assembly 4W315C Reference Part No.
Dayton Operating Instructions and Parts Manual 24 Dayton Diesel Electric Generator ® 4W315C 107358 4W315C 1 3 14 11 1 2 0 V O L T S RESET TEST 2 4 2 1 2 0 /2 4 0 V O L T S R E S E T R E S E T 7 6 6 9.
Dayton Operating Instructions and Parts Manual 25 Model 4W315C Version B - For Reduction G016.J ® 107358 Repair Parts List for Contr ol Panel 4W315C Reference Part No.
Dayton Operating Instructions and Parts Manual 26 Dayton Diesel Electric Generator ® 4W315C 107358 4W315C 17 16 15 7 8 9 14 21 23 4 4 4 4 10 11 12 13 12 20 18 19 3 6 3 5 22 2 3 1 Figure 31 – Repair.
Dayton Operating Instructions and Parts Manual 27 Model 4W315C Version B - For Reduction G016.J ® 107358 4W315C Repair Parts List for Switch Contr ol Box Reference Part No.
Dayton Operating Instructions and Parts Manual Dayton Diesel Electric Generator ® 4W315C Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. NOTE: The five-year limited warranty below covers all non-engine parts of this generator including the alternator .
デバイスDayton 4W315Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dayton 4W315Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDayton 4W315Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dayton 4W315Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dayton 4W315Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dayton 4W315Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDayton 4W315Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dayton 4W315Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDayton 4W315Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。