Dell Storage Center SC100 and SC120 Expansion Enclosure Getting Started Guide Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Before You Begin Consider the following best practices before setting up your SC100/SC120 expansion enclosure. • Before connecting any cables between the storage system and expansion enclosure, physically label each port and connector. • Always follow proper power-up and power-down procedures when cycling power across the network.
Figure 1. SC100/SC120 Expansion Enclosure Components 1. Documentation 2. Expansion enclosure 3. Rack rails 4. Front bezel Installing the Expansion Enclosure in a Rack Install the SC100/SC120 expansion enclosure in a rack.
For more information about installing the expansion enclosure, see the Dell Storage Center SCv2000/SCv2020 Storage System Deployment Guide . Installing the Front Bezel Install the bezel on the front of the expansion enclosure. 1. Hook the right end of the bezel onto the expansion enclosure.
Figure 4. Cabling an SC100/SC120 Expansion Enclosure to an SCv2000/SCv2020 Storage System 1. Storage system 2. Storage controller 1 3. Storage controller 2 4. SC100/SC120 expansion enclosure 1 5. SC100/SC120 expansion enclosure 2 Connecting the Power Cables Connect power cables to the expansion enclosure.
Turning on the Expansion Enclosure Turn on the SC100/SC120 expansion enclosure after racking and cabling all of the Storage Center components. Turn on the expansion enclosure by pressing both power switches at the same time.
Enclosure Management Modules (EMMs) EMMs Two hot-swappable IO modules Connectivity Configurations Storage Center supports up to 168 drives in one redundant-path SAS chain • An SCv2000 supports up to.
Power Supplies AC power supply (per power supply) Wattage 700 W Voltage 100–240 VAC (8.6–4.3 A) Heat dissipation SC100 : 191–147 W SC120 : 133–114 W Maximum inrush current Under typical line c.
Environmental Operating 5° to 40°C (41° to 104°F) with a maximum temperature gradation of 10°C per hour NOTE: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F per 550 ft.
デバイスDell SC120の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dell SC120をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDell SC120の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dell SC120の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dell SC120で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dell SC120を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDell SC120の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dell SC120に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDell SC120デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。