DeLonghiメーカーDEFSGG 24 SSの使用説明書/サービス説明書
ページ先へ移動 of 20
IMPORT ANT - PLEASE READ AND FOLLOW ✓ Before beginning, please r ead these instructions completely and carefully . ✓ Do not remove permanently af fixed labels, warnings, or plates from the product. This may void the warranty . ✓ Please observe all local and national codes and ordinances.
2 ✓ Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
3 DA T A PLA TE CONVERSION LABEL This appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any none domestic application and therefor e should not be used in a commercial envir onmement. The appliance guarantee will be void if the appliance is used within a none domestic environnement i.
4 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier .
5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition.
6 (303 m m ) (303 m m ) 11" 15/16 11" 15/16 (150 mm) 5" 57/64 installation PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. Range dimensions: • width: 23” 7/8 (606.
7 A B A (914 mm) 36" 30" min. (762 mm) (457 mm) 18" min. 0" 0" (0 m m ) (0 m m ) 20" min. (500 mm) 1 1 " 13/16 m in . (3 0 0 m m ) 13" max. (330 mm) 0" (0 m m ) 3" min. (76 mm) 13" max. (330 mm ) (914 mm) 36" 0" (0 m m ) 2 0 " m in .
8 LEVELLING THE RANGE The range is equipped with 4 LEVELLING FEET and may be levelled by scr ewing or unscrewing the feet with a spanner (fig. 1.8). It is important to observe the directions of figures 1.6, 1.7a, 1.7b . + 8 mm + 5/16" + 8 mm + 5/16" 0 mm 0" + 20 mm + 25/32" Fig.
9 gas connection Gas supply line Shutoff valve “open” position To range Explosion Hazard Use a new CSA or UL approved gas supply line. Install a shut-off valve. Securely tighten all gas connec- tions. If connected to LP , have a quali- fied person make sure gas pr es- sure does not exceed 14" water column.
10 PRESSURE REGULA TOR INST ALLA TION LOCK Arrow STEP 1 Mount the 1/2” NPT (conical) male connector to the pressur e r egulator and tighten by using a wr ench.
11 To mains connection Manifold test point pressure 1/8” NPT To range Range manifold Manifold male pipe fitting Connector Pressure regulator 1/2” G cylindrical (ISO 228-1) male 1/2” G cylindrical (ISO 228-1) female 1/2” NPT (conical) male 1/2” NPT female 1/2” NPT female WARNING: check the right positioning of the gas regulator.
12 To mains connection To range Manifold test point pressure 1/8” NPT Screw Unscrew Fig. 2.5 5. Leak T esting: IMPORT ANT : Leak testing of the appliance shall be conducted as follows: • After.
13 1 2 3 4 Fig. 2.6b Fig. 2.6a REGULA TOR COVER Pressur e r egulator CONVERSION TO LP/PROP ANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced accor ding to the “INJECTORS T ABLE”.
14 SETTING THE BURNER MINIMUM When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame.
15 OPERA TIONS TO BE EXECUTED FOR THE REPLACEMENT OF THE INJECTORS OF THE OVEN AND BROIL BURNERS a) Oven Burner – Lift and remove the lower panel inside the oven. – Remove the burner securing screw (fig. 2.10). – Withdraw the burner as shown in figure 2.
16 After regulation r epeat the operations indicated in paragraph “2. Pressure r egulator” at page 9. If the range has been disconnected and then connected again to the gas supply line r epeat the operations indicated in paragraph “5. Leak T esting” at page 12.
17 electrical connection If codes permit and a separate ground wir e is used, it is recommended that a qualified electrician determine that the ground path is adequate. Check with a qualified electrician if you are not sur e whether the range is proper- ly grounded.
18 WIRING DIAGRAM Fig. 3.2 P1 F1 MS AS CF N/7 L/8 S1 PA TL3 V T LF EC A M N L ELECTRIC DIAGRAM KEY F1 Switch MS Security microswitch S1 Cooling fan safety lamp LF Oven lamp AS Air switch V Fan TL3.
19.
Cod. 1102749 - ß3 The manufacturer cannot be held responsible for possible inaccuracies due to printing or transcription err ors in the present booklet.
デバイスDeLonghi DEFSGG 24 SSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
DeLonghi DEFSGG 24 SSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDeLonghi DEFSGG 24 SSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。DeLonghi DEFSGG 24 SSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。DeLonghi DEFSGG 24 SSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
DeLonghi DEFSGG 24 SSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDeLonghi DEFSGG 24 SSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、DeLonghi DEFSGG 24 SSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDeLonghi DEFSGG 24 SSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。