DesaメーカーCCL3930NRの使用説明書/サービス説明書
ページ先へ移動 of 28
Save this manual for future reference. WARNING: Improper installation, ad- justment, alteration, service, or mainte- nance can cause injury or property dam- age. Refer to this manual for correct installation and operational procedures. For assistance or additional informa- tion consult a qualified installer, ser- vice agency, or the gas supplier.
2 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly.
3 107553 OWNER’S MANUAL For more information, visit www.desatech.com AUTO ON OFF COOLER WARMER TEMP PRODUCT IDENTIFICA TION Figure 1 - Yellow Flame Vent-Free Gas Log Heater Shown (Logs May Vary by Model) OPERATION This heater is clean burning. It requires no outside venting.
4 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes.
5 107553 OWNER’S MANUAL For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 107553 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION WARNING: A qualified ser- vice person must install heater. Follow all local codes.
8 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com INST ALLA TION Continued Heat Resistant Material (A) Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, go to If Using Mantel .
9 107553 OWNER’S MANUAL For more information, visit www.desatech.com INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf.
10 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY IMPORTANT: Make sure the heater burn- ers are level. If heater is not level, heater will not work properly.
11 107553 OWNER’S MANUAL For more information, visit www.desatech.com CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings. INST ALLA TION Continued Continued CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply.
12 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com INST ALLA TION Continued Figure 14 - Equipment Shutoff Valve ON POSITION OFF POSITION Open Equipment Shutoff Va.
13 107553 OWNER’S MANUAL For more information, visit www.desatech.com AUTO OFF ON 3 AUTO OFF ON INST ALLA TION Continued AUTO OFF O N WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
14 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com A U T O OFF ON INST ALLA TION Continued Figure 25 - Installing Crossover Log (#4) 4. Locate the notches in the bottom of the crossover log (#4). Place the crossover log on top of the middle log and front log.
15 107553 OWNER’S MANUAL For more information, visit www.desatech.com 1. STOP! Read the safety inf ormation in columns 1 and 2. 2. Make sur e equipment shutoff valve is fully open.
16 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com TO TURN OFF GAS TO APPLIANCE 1. Follow steps 1 thr ough 6 under Light- ing Instructions , pages 15 and 16. 2. Depress contr ol knob and light pilot with match. 3.
17 107553 OWNER’S MANUAL For more information, visit www.desatech.com OPERA TING HEA TER Continued Thermocouple Pilot Burner Figure 37 - Correct Pilot Flame Pattern Figure 38 - Incorrect Pilot Flame Pattern INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often.
18 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean.
19 107553 OWNER’S MANUAL For more information, visit www.desatech.com Continued TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
20 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com OBSERVED PROBLEM Burner does light after ODS/pilot is lit Delayed ignition burner Burner backfiring during comb.
21 107553 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
22 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN CGD3924NRA 7 16 16 17 25 16 3 2 1 4 11 21 10 9 12 15 8 19 18 20 6 14 5 13 27 26.
23 107553 OWNER’S MANUAL For more information, visit www.desatech.com This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIST CGD3924NRA KEY NO.
24 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com ILLUSTRA TED PAR TS BREAKDOWN CCL3924NR CCL3930NR 30 18 18 19 27 18 13 23 12 11 14 4 5 1 2 17 10 21 20 22 6 7 3.
25 107553 OWNER’S MANUAL For more information, visit www.desatech.com PAR TS LIST CCL3924NR CCL3930NR KEY CCL3924NR CCL3930NR NO. PART NUMBER PART NUMBER DESCRIPTION QTY.
26 107553 UNVENTED NA TURAL GAS LOG HEA TER For more information, visit www.desatech.com Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
27 107553 OWNER’S MANUAL For more information, visit www.desatech.com SPECIFICA TIONS CGD3924NRA Btu (Variable) 20,000/39,000 Type Gas Natural Gas Only Ignition Piezo Manifold Pressure 3.5" W.C. Inlet Gas Pressure (in. of water) Maximum 10.5" Shipping Weight 30 lbs.
LIMITED WARRANTY COMFORT GLOW VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスDesa CCL3930NRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CCL3930NRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CCL3930NRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CCL3930NRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CCL3930NRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CCL3930NRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CCL3930NRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CCL3930NRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CCL3930NRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。