UNVENTED (VENT -FREE) GAS COMP ACT CLASSIC HEAR TH ® DUAL BURNER FIREPLACE OWNER’S OPERATION AND INSTALLATION MANUAL Save this manual for future reference.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 2 WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace. WARNING: Do not allow fans to blow directly into the fireplace.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 SAFETY INFORMA TION Continued SAFETY INFORMATION PRODUCT IDENTIFICATION 1. This appliance is only for use with the type of gas indicated on the rating plate.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 4 LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation Determining Fresh-Air Flow for Fireplace Location AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy efficient than ever.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 6 3. Add the Btu/Hr of all fuel burning appliances in the space.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 Figure 5 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 8 FIREPLACE CLEARANCES WARNING: Maintain the minimum clearances shown in Figure 6. If you can, provide greater clear- ances from floor, ceiling, and joining wall.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 Actual Framing Height 26" 26 7 / 8 " Front Width 26 3 / 4 " 26 7 / 8 " Depth 14 1 / 4 " 15 1 / 4 " 1. Frame in rough opening.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 10 INST ALLA TION Continued Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 O F F P I L O T O N H I L O Figure 12 - Attaching Brass Trim to Fireplace Shoulder Screw Asse.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 12 3 2 1 O F F P I L O T O N H I L O Installing Blower Accessory Note: If you are using a mantel with your fireplace, use the following instructions. If your fireplace is built-in, see For Built-In Installation, page 13.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 3 2 1 O F F P I L O T O N H I L O Red Red Fan Switch (Auto/Off/On) Blue Blue Thermostat Switch (N.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 14 Installation must include an equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figures 20).
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 NOTICE: Most building codes do not permit con- cealed gas connections. A flexible gas line is pro- vided to allow accessibility from the fireplace (see Figure 31).
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 16 Figure 24 - Checking Gas Joints (Propane/LP Only) Propane/LP Supply Tank Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Figure 25 - Checking Gas Joints (Natural Gas Only) 3.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 INST ALLA TION Continued INSTALLATION Optional Wireless Hand-Held Remote Control Accessories .
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 18 OPTIONAL WALL SWITCH - GWMS2 (Remote-Ready Models Only) WARNING: Do not connect this switch to any electri- cal source! Electrical shock and/or fire hazard will occur.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 INSTALLING LOG SET AND SCREEN 1. Remove log packaging material and discard packaging. Gen- tly place log over burner (see Figure 34). Do not allow log to contact flame.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 20 TO TURN OFF GAS TO APPLIANCE 1. F ollo w steps 1 through 5 under Lighting Instructions , begin- ning on page 19. 2. W ith control knob pr essed in, strike match.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 OPERATING FIREPLACE (REMOTE-READY MODELS) For Your Safety Read Before Lighting Lighting Instr.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 22 Figure 42- Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Remote Operat.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 OPERA TING FIREPLACE Continued OPERATING FIREPLACE (REMOTE-READY MODELS) Optional Hand-Held Remote Operation (Cont.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 24 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 46 shows a correct pilot flame pattern. Figure 47 shows an incorrect pilot flame pattern.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 CLEANING AND MAINTENANCE Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.) Log Set Cabinet WIRING DIAGRAM Figure 50 - Injector Holder On Outlet Burner Tube Burner Tube Injector Holder Primary Air Inlet Holes 5.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 26 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and unplug fireplace and let cool before servic- ing.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delay.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 28 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 Thermostat Models: Thermostat Models: Remote-Ready Models: Remote-Ready Models: CDCFTP, VDCFT.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 30 ILLUSTRA TED P ARTS BREAKDOWN FIREBOX ILLUSTRATED PARTS BREAKDOWN Firebox 8 8 19 19 19 19 19 19 .
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 32 ILLUSTRA TED P ARTS BREAKDOWN THERMOSTAT MODELS FDCFTP, FDCFTN, VDCFTP, VDCFTN, CDCFTP and CDCFT.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 P AR TS LIST THERMOSTAT MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 34 ILLUSTRA TED P ARTS BREAKDOWN REMOTE-READY MODELS FDCFRN, FDCFRP, VDCFRN and VDCFRP ILLUSTRATED .
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 35 35 P AR TS LIST REMOTE-READY MODELS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 36 CORNER MANTEL WITH FULL HEARTH BASE CMA208F Series - French Walnut CMA209U Series - Unfinished For all models. Space-saving mantel and hearth base corner design features clean, classic lines.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 37 37 RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTB AND CGHRCTB For all remote-r eady m odels. Allows the fireplace to be operated in a manually or thermostatically controlled mode.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 38 NOTES __________________________________________________________________________________________.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 39 39 • ACCESSORIES 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 40 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 41 41 NOTES _______________________________________________________________________________________.
111244-01A For more information, visit www.desatech.com For more information, visit www.desatech.com 42 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.
デバイスDesa CDCFTNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CDCFTNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CDCFTNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CDCFTNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CDCFTNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CDCFTNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CDCFTNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CDCFTNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CDCFTNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。