Save this manual for future reference. ® YELLO W FLAME DESIGN UNVENTED (VENT -FREE) PR OP ANE/LP GAS LOG HEA TER (Also Designed Certified as Vented Decorative Appliance) This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
2 102989 CONTENTS SECTION PAGE SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
3 102989 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 102989 PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Gas Log Heater LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*.
5 102989 AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
6 102989 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
7 102989 AIR FOR COMBUSTION AND VENTILA TION Continued WARNING ICON G 001 W ARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
8 102989 WARNING ICON G 001 W ARNING Never install the heater • in a bedroom or bathroom except as a vented appliance (see page 13) • in a recreational vehicle • where curtains, furniture, cloth.
9 102989 INST ALLING Continued Continued INSTALLATION AND CLEARANCES (Vent-Free Operation Only) W ARNING Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining wall. Carefully follow the instructions below.
10 102989 Heat Resistant Material (A) INST ALLING Continued NOTICE You may use this heater as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fire- place opening is not needed.
11 102989 INST ALLING Continued Minimum Non Combustible Material Clearances If Using Mantel You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick.
12 102989 14" Min. Combustible Material Non-Combustible Material Hearth 5" Min. Combustible Material INST ALLING Continued Floor Clearances A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
13 102989 INST ALLING Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of non combustible material.
14 102989 INST ALLING Continued INSTALLING HEATER BASE ASSEMBLY WARNING ICON G 001 W ARNING If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against soot- ing.
15 102989 INST ALLING Continued CONNECTING TO GAS SUPPLY NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. WARNING ICON G 001 CAUTION Never connect heater directly to the propane supply. This heater requires an external regulator (not supplied).
16 102989 INST ALLING Continued The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur.
17 102989 WARNING ICON G 001 CAUTION Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings. Figure 14 - Gas Connection * Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer.
18 102989 ON POSITION OFF POSITION 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
19 102989 INST ALLING Continued WARNING ICON G 001 W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Each log is marked with a number.
20 102989 OPERA TING HEA TER 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Press in and turn control knob clockwise Clockwise to the OFF position. Figure 20 - Control Knob and Ignitor Button Location 4.
21 102989 OPERA TING HEA TER Continued T O TURN OFF GAS T O APPLIANCE Shutting Off Heater 1. Press in and turn control knob clockwise Clockwise to the HIGH position. 2. Turn control knob clockwise Clockwise to the pilot position. 3. Press in control knob and turn clockwise Clockwise to the OFF position.
22 102989 INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple.
23 102989 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use.
24 102989 TROUBLE- SHOOTING Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3 . Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5.
25 102989 TROUBLE- SHOOTING Continued OBSERVED PROBLEM Burner does light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensa- tion noticed on windows Heater produces a whistling noise when burner is lit REMEDY 1.
26 102989 TROUBLE- SHOOTING Continued W ARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
27 102989 TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
28 102989 Note: Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty. Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replace- ment part(s), call DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).
29 102989 ACCESSORIES MANUAL SHUTOFF VALVE - GA5010 For all models. Manual shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. BLACK FIREPLACE HOOD - GA6050 For all models. Helps deflect heat away from mantel or wall above fireplace. BRASS FIREPLACE HOOD - GA6052 For all models.
30 102989 ILLUSTRA TED P ARTS BREAKDOWN 4 2 1 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20-2 20-1 20 18 23 CGS2718P CGS3124P.
31 102989 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 28 of this manual.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
デバイスDesa CGS2718Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa CGS2718Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa CGS2718Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa CGS2718Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa CGS2718Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa CGS2718Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa CGS2718Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa CGS2718Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa CGS2718Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。