DesaメーカーFSBVBNCの使用説明書/サービス説明書
ページ先へ移動 of 32
CAST IRON STOVE AND B-VENT (FREEST ANDING FIREPLACE HEA TER) BURNER SYSTEM OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS BURNER SYSTEM MODEL FSBVBNC PROP ANE/LP GAS BURNER SYSTEM MODEL FSBVBPC REMOTE READY Save this manual for future reference.
2 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
3 107600 OWNER’S MANUAL For more information, visit www.desatech.com PRODUCT IDENTIFICA TION Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA- B149[.
4 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your FMI B-vent freestanding stove. Make sure that rafters and wall studs are not in the way of the venting system.
5 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body .
6 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBL Y Continued 9. Attach stove door by inserting step bolt through door hinge pivot hole and into threaded hole in stove body (see Fig- ure 9, page 5 and Figure 1 1).
7 107600 OWNER’S MANUAL For more information, visit www.desatech.com CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBL Y Continued Continued INSTALLING B-VENT BURNER SYSTEM INTO STOVE BODY 1. Carefully lift burner system and place into stove body from the rear of stove (see Figure 16).
8 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CAST IRON STOVE AND B-VENT BURNER SYSTEM ASSEMBL Y Continued WARNING: Never touch the blower wheel while in operation.
9 107600 OWNER’S MANUAL For more information, visit www.desatech.com INSTALLING REAR COVER 1 . Place rear cover behind stove body . Rear cover will rest on the bottom ledge of the stove body . 2 . Place wire harness from ON/OFF switch under the cast of stove body .
10 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com Figure 23 - Typical B-Vent Installation WARNING: Installation should only be made by qualified per- sons who ar.
11 107600 OWNER’S MANUAL For more information, visit www.desatech.com VENTING INST ALLA TION Continued Figure 25 - Vertical Venting Configuration Through Chimney Figure 26 - Venting Through a Side Wall Continued CHECKING VENT CAPACITY Complete all gas piping, electrical, and vent connections.
12 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com HIGH ALTITUDE INSTALLATION Your FM I B-vent freestanding stove and burner system has been AGA tested and approved for elevations from 0-2000 feet and CGA certified for elevations from 0-4500 feet.
13 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE AND B-VENT BURNER SYSTEM INST ALLA TION INSTALLING GAS PIPING TO FIREPLACE LOCATION WARNING: A qualified in- staller or service person must connect burner system to gas supply.
14 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com Cap Pipe Nipple Tee Joint Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping systems.
15 107600 OWNER’S MANUAL For more information, visit www.desatech.com STOVE AND B-VENT BURNER SYSTEM INST ALLA TION Continued Continued 4. Check all joints of gas supply piping system. Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak.
16 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1, GWMS2 WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.
17 107600 OWNER’S MANUAL For more information, visit www.desatech.com REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see Replacement Parts , page 26.
18 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding stove with burner system. 1. Remove glass door .
19 107600 OWNER’S MANUAL For more information, visit www.desatech.com TO TURN OFF GAS TO APPLIANCE 1. Set selector switch, located on side of rear co ver , i n the “OFF” position. 2a. Open lower door panel. 2b . If Using Optional Hand-Held Remote: Set selector switch in the OFF posi- tion to pre vent draining battery .
20 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com 1. After lighting, let pilot flame bur n f or about one minute. T urn control knob on the control valv e to ON position. T urn flame adjustment knob any- where between HI and LO.
21 107600 OWNER’S MANUAL For more information, visit www.desatech.com INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling.
22 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: Turn off burner sys- tem and let cool before cleaning. CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of stove and burner system clean.
23 107600 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
24 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during comb.
25 107600 OWNER’S MANUAL For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
26 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com SER VICE HINTS When Gas Pressure is Too Low • pilot will not stay lit • burners will have delayed ignition .
27 107600 OWNER’S MANUAL For more information, visit www.desatech.com SPECIFICA TIONS FSBVBNC FSBVBPC 21,000-30,000 Btu/h 20,000-28,000 Btu/h Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.
28 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN FSBVBNC FSBVBPC L O H I P I L O T OFF ON 4 4 17 18 19 21 23 -1 23-4 23-2 23-3 2.
29 107600 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST FSBVBNC FSBVBPC This list contains replaceable parts used in your burner system. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
30 CAST IRON STOVE AND BURNER SYSTEM 107600 For more information, visit www.desatech.com ILLUSTRA TED PA R T S BREAKDOWN FMI STOVE (P)FC SERIES 1R 1C 1L 5 8 8 7-4 6 5 5 7-1 7-2 5 4 7-3 2 3 (Discarded .
31 107600 OWNER’S MANUAL For more information, visit www.desatech.com P ARTS LIST FMI STOVE (P)FC SERIES This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual.
LIMITED WARRANTY B-VENT BURNER SYSTEM AND FMI STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスDesa FSBVBNCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa FSBVBNCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa FSBVBNCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa FSBVBNCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa FSBVBNCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa FSBVBNCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa FSBVBNCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa FSBVBNCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa FSBVBNCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。