DesaメーカーREM200Tの使用説明書/サービス説明書
ページ先へ移動 of 16
ARL LOGO G 004 ® IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury.
2 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alco- hol, or other highly flammable fuels.
3 106068 OWNER’S MANUAL 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for shipping damage.
4 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR WARNING: Use only kero- sene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. Do not use heavy fuels such as No.
5 106068 OWNER’S MANUAL THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
6 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR Item How Often How To Fuel tank Flush every 150-200 hours See Storing, Transporting, or of operation or as needed Shipping Air output and Replace .
7 106068 OWNER’S MANUAL WARNING: Never service heater while it is plugged in, operat- ing, or hot. Severe burns and electrical shock can occur. TROUBLESHOOTING OBSERVED FAULT Heater ignites, but fla.
8 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR SER VICE PROCEDURES UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-driver . These screws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard.
9 106068 OWNER’S MANUAL PUMP PRESSURE ADJUSTMENT 1. Remove pressure gauge plug from filter end cover . 2. Install accessory pressure gauge (part number HA1 180). 3. Start heater (see Operation , page 5). Allow motor to reach full speed. 4. Adjust pressure to 6.
10 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 9. Blow compressed air through face of nozzle. This will free any dirt in nozzle area. 10. Inspect nozzle seal for damage. 1 1. Replace nozzle into burner head and tighten firmly (80-1 10 inch-pounds).
11 106068 OWNER’S MANUAL PUMP ROTOR (Procedure if Rotor is Binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-driver . 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-driver .
12 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN REM200T Motor and Pump Assembly 7-1 7-8 Burner Head Assembly 7-7 7-3 7-4 7-5 7-6 10-16 10-17 10-15 10-18 10-14 10.
13 106068 OWNER’S MANUAL P ARTS LIST REM200T 200,000 Btu/Hr This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part.
14 106068 POR T ABLE FORCED AIR HEA TER 200,000 BTU/HR 1 2 3 4 WHEELS AND HANDLE PARTS LIST KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 HA2204 Handles 2 2 M12345-33 Screw, #10-24 x 1 3 / 4 "8 3 M.
15 106068 OWNER’S MANUAL White Black Black Blue Green Power Plug 120V/60Hz Photocell Spark Plug Ignitor Flame-Out Control B Reset Button R Red Red Motor Blue White White White White White Red Red Green Terminal Board Red Black Relay Fuel Valve Green/Yellow Thermostat WIRING DIAGRAM Note: Use only original replacement parts.
W ARRANTY AND REP AIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship.
デバイスDesa REM200Tの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa REM200Tをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa REM200Tの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa REM200Tの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa REM200Tで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa REM200Tを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa REM200Tの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa REM200Tに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa REM200Tデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。