DesaメーカーREM50PVAの使用説明書/サービス説明書
ページ先へ移動 of 14
PROP ANE CONSTRUCTION HEA TER OWNER’S MANUAL GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POI- SONING, AND/OR ELECTRICAL SHOCK.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 2 105331 SAFETY INFORMA TION WARNING: FIRE, BURN, IN- HALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUS- TIBLES, SUCH AS BUILDING MA- TERIALS, PAPER OR CARD- BOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE IN- STRUCTIONS.
OWNER’S MANUAL 3 105331 PRODUCT IDENTIFICA TION Figure 1 - 50,000 BTU/Hr Model UNP ACKING 1. Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage. 2. Remove all items from carton.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 4 105331 Air For Combustion Air For Heating THEOR Y OF OPERA TION Combustion Chamber THE FUEL SYSTEM The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater. THE AIR SYSTEM The motor turns the fan.
OWNER’S MANUAL 5 105331 INST ALLA TION Valve Inlet Hose Figure 7 - Hose and Inlet Connector WARNING: Review and un- derstand the warnings in the Safety Information section, page 2. They are needed to safely op- erate this heater. Follow all local codes when using this heater.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 6 105331 OFF MED HIGH ST ART/ LOW STORAGE 1. Store propane tank(s) in safe manner . See Chapter 5 of Standar d for Storage and Handling of Liquefied Petr oleum Gases, ANSI/NFP A 58. Follow all lo- cal codes.
OWNER’S MANUAL 7 105331 REMEDY 1. Check voltage to electrical outlet. If volt- age is good, check heater power cord for breaks 2. Adjust motor/fan guard to keep fan from hitting inside of heater shell. Bend fan guard if necessary 3. Replace fan. See Fan, page 9 4.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 8 105331 SER VICE PROCEDURES WARNING: Never service heater while it is plugged in, con- nected to propane supply, oper- ating, or hot. Severe burns and electrical shock can occur. You can also visit DESA International’s Technical Service web site at www.
OWNER’S MANUAL 9 105331 IGNITOR 1. Remove motor and fan guard from heater (see Motor , page 8, steps 1 through 5). 2. Remove black ignitor wire from piezo ignitor . Access ignitor wire through un- derside of heater base (see Figure 17). Push wire up through bushing in heater shell.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 10 105331 28 27 15 17 18 21 1 2 3 2 4 6 7 9 11 21 22 23 24 25 19 2 10 26 16 12 13 14 5 20 20 8 ILLUSTRA TED P ARTS BREAKDOWN RLP50VA BLP50VA REM50PVA.
OWNER’S MANUAL 11 105331 P AR TS LIST RLP50VA BLP50VA REM50PVA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY PART NO. NO. DESCRIPTION QTY.
PROP ANE CONSTRUCTION HEA TER 50,000 BTU/HR 12 105331 SPECIFICA TIONS Output Rating (BTU/Hr) High 49,500 Low 30,000 Fuel Propane Vapor Only Fuel Consumption Gallons/Hour 2.
OWNER’S MANUAL 13 105331 NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
W ARRANTY AND REP AIR SER VICE LIMITED WARRANTY KEEP THIS WARRANTY For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include model number and serial number.
デバイスDesa REM50PVAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa REM50PVAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa REM50PVAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa REM50PVAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa REM50PVAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa REM50PVAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa REM50PVAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa REM50PVAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa REM50PVAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。