DesaメーカーSB600Dの使用説明書/サービス説明書
ページ先へ移動 of 20
350 SIDE PV 026 Heater Sizes: 350,000 and 600,000 Btu/Hr Models: SB350D and SB600D ARL LOGO G 004 ® OWNER’S MANUAL HIGH PRESSURE POR T ABLE FORCED AIR HEA TERS 600 SIDE PV 027 IMPORTANT: Read and understand this manual before assembling, start- ing, or servicing heater.
2 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly.
3 106029 OWNER’S MANUAL PRODUCT IDENTIFICA TION Upper Shell Power Cord Thermostat Fuel Cap Fuel Tank Hot Air Outlet Lower Shell Power Cord Fuel Tank Hot Air Outlet Upper Shell Motor and Pump Assembl.
4 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 diesel. Using heavy fuels will result in: • clogged fuel .
5 106029 OWNER’S MANUAL OPERA TION To Start Heater 1. Follo w all ventilation and safety infor - mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Set thermostat dial to desired tempera- ture. Note: Thermostat setting must be higher than surrounding air temperature.
6 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR PREVENT A TIVE MAINTENANCE SCHEDULE Item Fuel tank Filler neck screen Fuel filter assembly (Fuel tank) Fuel filter lin.
7 106029 OWNER’S MANUAL OBSERVED PROBLEM WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.
8 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR OBSERVED PROBLEM Heater will not ignite, but motor runs for a short period of time. 1. A) Add fuel to tank B) Check fuel tank for bubbles of water in bottom. If found, remove fuel (see Storing, T ransporting, or Shipping , page 5).
9 106029 OWNER’S MANUAL OBSERVED PROBLEM Heater ignites, but flame-out control shuts off heater after a short period of time Heater burns, but puffs of smoke can be seen Heater does not burn steady Heater burns with odor Heater smokes continuously 1.
10 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Figure 7 - Spark Plug Removal Spark Plug Wire Spark Plug Burner Head Spark Plug 1. Remove upper shell (see column 1). 2. Remove spark plug wire from spark plug (see Figure 7).
11 106029 OWNER’S MANUAL Pump (Procedure if Pump is Binding) 1. Remove upper shell (see page 10). 2. Loosen hex screw on flange clamp at rear of motor with 5/16" nut-driv er (see Figure 11). 3. T urn fan with hand (see Figure 12). 4. If fan turns freely , tighten screw on flange clamp.
12 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR Fuel Filter Fuel Lines Fuel Filters A. T ank Fuel Filter 1. Disconnect fuel lines from pump and pump fuel filter assembly with 7/16" wrench (see Figure 15). 2. Carefully pry fuel filter loose from fuel tank with flat end of screwdr iver .
13 106029 OWNER’S MANUAL SPECIFICA TIONS 350,000 Btu/Hr 600,000 Btu/Hr Output Rating (Btu/Hr) 350,000 600,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gallons) 30 36 Fuel Consumption (Gallons Per Hr) 2.5 4 Electric Requirements 120V/60 Hz 120V/60 Hz Amperage (Normal Run) 7.
14 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN SB350D 350,000 BTU/HR 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25 .
15 106029 OWNER’S MANUAL REF. NO. PART NO. DESCRIPTION QTY. 1 099329-02 Upper shell model SB350D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 15 3 M50542-01 Combustion chamber & shield 1 4 M.
16 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR ILLUSTRA TED PA R T S BREAKDOWN SB600D 600,000 BTU/HR 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 .
17 106029 OWNER’S MANUAL P ARTS LIST SB600D 600,000 BTU/HR REF. NO. PART NO. DESCRIPTION QTY. 1 099329-04 Upper shell model SB600D (Yellow) 1 2 M11084-27 Screw, #10-16 x 1/2" 28 3 M50543-01 Com.
18 106029 HIGH PRESSURE POR T ABLE FORCED AIR HEA TER 350,000 AND 600,000 BTU/HR 4 9 8 7 6 5 3 1 2 REF NO. PART NO. DESCRIPTION QTY. 1 M10908-2 Screw, #6-32 x 3/8" (350,000 Btu/Hr Only) 2 2 09922.
19 106029 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
For information, write: DESA International, P.O. Box 90004 Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department When writing, always include Model number and Serial number. W ARRANTY AND REP AIR SERVICE PARTS AND SERVICE UNDER WARRANTY Should your heater require service, return it to your nearest authorized service center.
デバイスDesa SB600Dの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa SB600Dをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa SB600Dの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa SB600Dの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa SB600Dで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa SB600Dを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa SB600Dの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa SB600Dに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa SB600Dデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。