DesaメーカーVFN30MVの使用説明書/サービス説明書
ページ先へ移動 of 24
UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER 1. This appliance is only for use with the type of gas indicated on the rating plate.
3 105070 OWNERS MANUAL PRODUCT IDENTIFICA TION Figure 1 - Ember Master Left Front Log Control Knob Rear Log Base Assembly Front Burner Piezo Ignitor Rear Burner Crossover Log Bottom Middle Log Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.
4 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Confined and Unconfined Space The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.
5 105070 OWNERS MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 105070 OWNERS MANUAL MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS Log Size 18", 24", 30" Side Wall 16" Ceiling 42" Floor 5" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances.
8 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Noncombustible Requirements for Material Distance (A) Safe Installation 12" or more Noncombustible material OK. Between 8" and 12" 24" and 30" Models: Install fireplace hood accessory (HDABK or HDABR, see Accessories , page 22).
9 105070 OWNERS MANUAL 14" Min. Combustible Material Non-Combustible Material Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level Hearth 5" Min. Combustible Material Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring FLOOR CLEARANCES A.
10 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.
11 105070 OWNERS MANUAL 10. Attach mounting brackets to fireplace floor using masonry screws (in hard- ware package). 1 1 . Reattach heater base to mounting brackets.
12 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. WARNING: Test all gas pip- ing and connections for leaks after installing or servicing.
13 105070 OWNERS MANUAL INST ALLA TION Continued WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. INSTALLING LOGS Each log is marked with a number.
14 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Figure 22 - Pilot Thermocouple Ignitor Electrode Pilot Burner 4. W ait fi ve (5) minutes to clear out any gas. Then smell f or gas, including near the floor . If you smell gas, STOP! F ollow “B” in the safety in- formation, column 1.
15 105070 OWNERS MANUAL TO TURN OFF GAS TO APPLIANCE WARNING: Do not operate heater between locked positions. CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve. The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained.
16 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER SPECIFICA TIONS 18" Variable 24" Variable 30" Variable Manually- Manually- Manually- Controlled Contro.
17 105070 OWNERS MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
18 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Bur.
19 105070 OWNERS MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
20 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER ILLUSTRA TED PA R T S BREAKDOWN VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV 17 19 18 25 24 20 20 26 .
21 105070 OWNERS MANUAL P ARTS LIST VARIABLE MANUALLY- CONTROLLED MODELS VFN18MV VFN24MV VFN30MV This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual.
22 105070 FIREPLACE MANUF ACTURERS INCORPORA TED UNVENTED NA TURAL GAS LOG HEA TER Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
23 105070 OWNERS MANUAL NOTES _______________________________________________________________________________________________ __________________________________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for one (1) year from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスDesa VFN30MVの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VFN30MVをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VFN30MVの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VFN30MVの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VFN30MVで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VFN30MVを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VFN30MVの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VFN30MVに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VFN30MVデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。