DesaメーカーVN6Cの使用説明書/サービス説明書
ページ先へ移動 of 20
Save this manual for future reference. INFRARED VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERATION AND INSTALLATION MANUAL ® MODELS: VN6C AND VN10 ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced.
3 101851 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide ad- equate combustion and ventila- tion air by one of the methods described in the National Fuel Gas Code, ANSI Z223.
5 101851 OWNER’S MANUAL Figure 3 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts.
6 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 2. Mark two mounting screw locations on wall (see Figure 5). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater . Figure 5 - Mounting Screw Locations WARNING: Maintain minimum clearances shown in Figure 5.
7 101851 OWNER’S MANUAL PLACING HEATER ON MOUNTING SCREWS 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2 . Place lar ge openings of slots over screwheads.
8 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/ or fittings. Figure 12 - Gas Connection * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
9 101851 OWNER’S MANUAL PRESSURE TESTING HEATER GAS CONNECTIONS 1. Open manual shutoff valve (see Figure 13). 2. Open main gas valve located on or near gas meter . 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from manual shutoff valve to control valve (see Figure 14).
10 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 TO SELECT HEATING LEVEL 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions (VN10) or ON position (VN6C). IMPORT ANT : Release downward pressur e while turning control knob.
11 101851 OWNER’S MANUAL BURNER FLAME PATTERN Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect burner flame pattern. Figure 20 - Correct Burner Flame Pattern (Model VN10 .
12 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 POSSIBLE CAUSE 1. Ignitor electrode positioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not connected to igni- tor cable 4. Ignitor cable pinched or wet 5. Piezo ignitor nut is loose 6.
13 101851 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial opera- tion Heater produces a clicking/ticking noise just after burner is lit or shut off REMEDY 1.
14 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 OBSERVED PROBLEM Gas odor even when control knob is in OFF position Gas odor during combustion Moisture/condensation noticed on windows REMEDY 1. Locate and correct all leaks (see Check- ing Gas Connections , page 9) 2.
15 101851 OWNER’S MANUAL You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Techni- cal Service Department at 1-800-323-5190.
16 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 P AR TS LIST VN6C This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. HEATER EXPLODED VIEW 7-1 7-2 ODS/PILOT KEY PART NO.
17 101851 OWNER’S MANUAL KEY PART NO. NUMBER DESCRIPTION QTY. 15 099057-01 Pressure Tap Fitting 1 16 098276-01 1/8 Pipe Plug 1 17 099468-08 Cabinet Assembly 1 18 099415-01 Gas Regulator 1 19 098303-.
18 101851 NA TURAL GAS HEA TER V ANGUARD VN6C AND VN10 NOTES _______________________________________________________________________________________________ ___________________________________________.
19 101851 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
LIMITED WARRANTY VANGUARD VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for three (3) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスDesa VN6Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VN6Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VN6Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VN6Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VN6Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VN6Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VN6Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VN6Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VN6Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。