DesaメーカーVP11の使用説明書/サービス説明書
ページ先へ移動 of 24
Save this manual for future reference. VENT -FREE PROP ANE GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL ® G I D E S I N N A E S T D C E R T I I F I E A M C R A S O C I A O N ® GS A Models: VP5A and VP1 1 W ARNING : Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage.
2 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ..........................
3 SAFETY INFORMA TION Continued ! WARNING ICON G 001 W ARNINGS Continued 1. Use only propane gas. Do not convert heater to use different fuel type. 2. Do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 3.
4 PRODUCT IDENTIFICA TION PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
5 INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow all local codes. Continued CHECK GAS TYPE Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
6 2. Mark two mounting screw locations on wall (see Figure 3). INSTALLING HEATER TO WALL Marking Screw Locations 1. Determine where you will locate heater.
7 Installing Two Mounting Screws Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit.
8 Placing Heater On Mounting Screws 1. Locate two keyhole slots on back panel of heater (see Figure 7). 2. Place large openings of slots over screwheads.
9 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water.
10 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Figure 11 - Gas Connection * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection.
11 3. Pressurize supply piping system by either using compressed air or opening propane supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once.
12 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Make sure manual shutoff valve is fully open. 3. Turn control knob clockwise Clockwise to the OFF position. Control Knob A.
13 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 12. If you don’t smell gas, go to the next step. 5. Press in control knob.
14 TO SELECT HEATING LEVEL Figure 16 - Burner Patterns 1. Slightly press in control knob and turn counterclockwise C-clockwise to the LOW or HIGH positions (VP11) or ON position (VP5A). IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position.
15 Shutting Off Heater 1. Turn control knob clockwise Clockwise to the OFF position. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise Clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Remove front panel (see Figure 8, page 8).
16 BURNER FLAME PATTERN Figure 19 shows a correct burner flame pattern. Figure 20 shows an incorrect burner flame pattern. Figure 19 - Correct Burner Flame Pattern (Model VP11 Shown) Figure 20 - Incor.
17 TROUBLE- SHOOTING POSSIBLE CAUSE 1 . Ignitor electrode posi- tioned wrong 2. Ignitor electrode broken 3. Ignitor electrode not con- nected to ignitor cable 4. Ignitor cable pinched or wet 5. Broken ignitor cable 6. Bad piezo ignitor 1. Gas supply turned off or manual shutoff valve closed 2.
18 REMEDY 1. Press in control knob fully 2. After ODS/pilot lights, keep control knob pressed in 10 seconds 3. Fully open manual shut- off valve 4. Hand tighten until snug, then tighten 1/4 turn more 5. A) Contact local pro- pane gas company B) Clean ODS/pilot (see CLEANING AND MAINTENANCE, page 16) or replace ODS/pilot assembly 6.
19 POSSIBLE CAUSE 1. Plaque damaged 2. Inlet gas pressure is too low 3. Control knob set be- tween locked positions 1. Residues from manu- facturing processes 1. Metal expanding while heating or contracting while cooling 1. Heater burning vapors from paint, hair spray, glues, etc.
20 If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
21 When gas pressure is too low • pilot will not stay lit • burner(s) will have delayed ignition • heater will not produce specified heat • propane gas supply may be low When gas quality is ba.
22 P ARTS LIST Model VP5A KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-01 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469.
23 KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 099467-01 Front Panel Assembly 1 3 099318-01 Grill Guard 1 4 098342-01 Grill Guard Clip 2 5 099469-02 Reflector Assembly .
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
デバイスDesa VP11の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VP11をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VP11の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VP11の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VP11で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VP11を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VP11の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VP11に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VP11デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。