DesaメーカーVYM27PRの使用説明書/サービス説明書
ページ先へ移動 of 26
UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER Also Design-Certified As A V ented Decorative Appliance ® ® Patent Pending P I L O T O F F O N LO REMOTE OFF HI FLAME-MAX ® Multi-Sided Log Design OWNER’S OPERA TION AND INST ALLA TION MANUAL VYM27PR Remote Control Ready Model Save this manual for future reference.
2 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea.
3 104675 OWNER’S MANUAL AUTO MAN OFF STATUS ON LO HI TEMP PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*.
4 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® PROVIDING ADEQUATE VENTILATION The following ar e excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
5 104675 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
6 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
7 104675 OWNER’S MANUAL INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.
8 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below.
9 104675 OWNER’S MANUAL INST ALLA TION Continued MANTEL CLEARANCES In addition to meeting noncombustible ma- terial clearances, you must also meet re- quired clearances between fireplace open- ings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below, you will need a hood.
10 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel.
11 104675 OWNER’S MANUAL 7. Mark screw locations through one hole on each side of the mounting bracket (see Figure 12). If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace.
12 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. CHECKING GAS CONNECTIONS 2. Cap of f open end of gas pipe where manual shutof f valv e was connected.
13 104675 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS It is very important to install the logs exactly as instructed.
14 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.
15 104675 OWNER’S MANUAL 8. Keep contr ol knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release contr ol knob. • If control knob does not pop out when released, contact a qualif ied service person or gas supplier f or repairs.
16 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OPERA TING HEA TER Continued TEMP ST A TUS HI LO MAN ON AUT O OFF Increases Room Temperature Decreases Room Temperature Turns Burner On and Off Shows Current Operation Mode Shows Temperature Setting Allows Burner to be Turned On and Off with the Hand- Held Remote Unit.
17 104675 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.
18 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight s.
19 104675 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
20 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SPECIFICA TIONS 27" Remote Ready Btu (Variable) 20,000/39,000 Type Gas Propane Only Ignition Piezo Pressure Manifold 8.0" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum* 11" Shipping Weight 32 lbs.
21 104675 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person.
22 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN VYM27PR 5 O F F P I L O T O N H I L O O F F P I L O T O N H I L O 1 9 3 2 13 12 15 14 18 17 12 12 .
23 104675 OWNER’S MANUAL P AR TS LIST VYM27PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual.
24 104675 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information.
25 104675 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
デバイスDesa VYM27PRの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Desa VYM27PRをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDesa VYM27PRの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Desa VYM27PRの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Desa VYM27PRで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Desa VYM27PRを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDesa VYM27PRの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Desa VYM27PRに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDesa VYM27PRデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。