*A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses. OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED AIR COMPRESSOR MODEL NO.
2 ENG MGP-102D-3A SAFETY GUIDELINES .......................... Cover Page WARRANTY STATEMENT .................................. 3 WARNING CHART ............................................. 4-6 GLOSSARY ............................................
3 ENG MGP-102D-3A LIMITED WARRANTY ❏ Retain original cash register sales receipt as proof of purchase for warranty work. ❏ Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s).
4 ENG MGP-102D-3A RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK. IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION.
5 ENG MGP-102D-3A WHAT CAN HAPPEN HOW TO PREVENT IT RISK FROM FLYING OBJECTS THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT, CHIPS, LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED , RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY.
6 ENG MGP-102D-3A MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING. ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COM- PRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY.
7 ENG MGP-102D-3A SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air delivery. PSIG or PSI: Pounds per square inch gauge. All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle.
8 ENG MGP-102D-3A Air Hose The air hose attached to your comporessor has an integral pressure adjusting valve at the working end of the hose. Should service or replacement be required, make sure that the pressure adjusting valve is present in the air hose line.
9 ENG MGP-102D-3A Compressed air from the outfit may contain water condensation. Do not spray unfiltered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instructions for the air tool or device.
10 ENG MGP-102D-3A P ARTS LIST P ARTS ABAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER Safety Valve ............................................ TIA-4150 Drain Valve .............................................. SS-2707 Pressure Valve Assembly ...
11 ENG MGP-102D-3A High discharge pressure. Cannot be adjusted lower. Adjustable pressure valve not func- tioning. Air Leaks Hose fitting loose. Prolonged excessive use of air. Decrease the amount of air usage. Your compres- sor is not large enough for the air requirement.
12 ENG MGP-102D-3A OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED AIR COMPRESSOR MODEL NO. 102D-3 (For Home Use Only) DeVilbiss Company Air Power • 213 Industrial Dr.
デバイスDeVillbiss Air Power Company 102D-3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
DeVillbiss Air Power Company 102D-3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDeVillbiss Air Power Company 102D-3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。DeVillbiss Air Power Company 102D-3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。DeVillbiss Air Power Company 102D-3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
DeVillbiss Air Power Company 102D-3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDeVillbiss Air Power Company 102D-3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、DeVillbiss Air Power Company 102D-3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDeVillbiss Air Power Company 102D-3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。